8.2.5.
Other Indoor Unit Operation Functions
8.2.5.1.
Auto button
Proceed with operation when the air conditioner is stopped.
(When the auto button is pressed during operation, the air conditioner is stopped.)
1. Emergency operation
Press the auto button and release it within 5 seconds to perform emergency operation.
Under normal condition (failure is not occurred) automatic operation is performed. In the event of a failure that still enables
operation to be performed, emergency operation is performed.
2. Forced cooling operation
press the auto button about 5-8 seconds (1 beep sound) to perform the forced cooling operation.
The air conditioner does not operate for 2 minutes if the room temperature is low (intake temperature below 16°C) so
just wait. The forced operation is performed after 2 minutes have elapsed.
3. Forced heating operation
Press the auto button about 8-11 seconds (2 beeps sound) to perform the forced heating operation.
4. Setting modes (Remote control transmission code, current switching mode)
The remote control transmission code selection mode is established by pressing the AUTO button about 11-16 seconds (3
beeps sound).
Select Remote Control Transmission Code
• There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor unit. The
indoor unit will only operate when received signal with same transmission code from remote control. This could prevent
signal interference when there are 2 more indoor unit installed nearby together.
• To change remote control transmission code, short or open jumpers at the remote control printed circuit board.