8.3.1.7.
Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
• Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Soft Dry, Fan]
Remote Control
—
Tab (rpm)
PSHi
CS-ME10DTEG
900
CS-E15DTEW
1070
CS-E18DTEW
1110
[Heating]
Remote Control
—
Tab (rpm)
PSHi
CS-ME10DTEG
900
CS-E15DTEW
1080
CS-E18DTEW
1110
—
O
O
SHi
Hi
Me+
900
830
790
1070
1000
940
1110
1040
970
—
O
O
SHi
Hi
Me+
900
830
780
1080
1010
920
1110
1050
950
O
O
Me
Me-
740
690
640
870
800
730
920
850
790
O
O
Me
Me-
730
680
630
830
730
630
860
770
680
64
O
—
—
Lo
Lo-
SLo
590
530
680
630
740
630
O
—
—
Lo
Lo-
SLo
590
530
590
530
630
540
—
SSLo
370
370
370
—
SSLo
370
300
370