Air conditioner indoor unit cs-e10jd3ea; cs-e15jd3ea; cs-e18jd3ea; cs-e21jd3ea outdoor unit single split outdoor unit cu-e10hbea; cu-e15hbea; cu-e18hbea; cu-e21hbea multi split outdoor unit cu-2e15gbe; cu-2e18cbpg; cu-3e18ebe; cu-3e18jbe; cu-3e23cbpg; c (12 pages)
Page 3
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE Unit CS-E15DKEW CU-E15DKE Piping Connection Port inch G ; Half Union 1/2” G ; 3-way valve 1/2” (Flare piping) inch L ; Half Union 1/4” L ; 2-way valve 1/4” Pipe Size inch G (gas side) ;...
Page 14
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE Attached accessories Indoor/Outdoor Unit Installation Diagram Applicable piping kit CZ-4F5, 7, 10BP (E15DK) Select the best location INDOOR UNIT • There should not be any heat source or steam near the unit.
Page 15
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE Attached accessories Indoor/Outdoor Unit Installation Diagram Applicable piping kit CZ-4F5, 7, 10BP (E18DK, E21DK) Select the best location INDOOR UNIT • There should not be any heat source or steam near the unit.
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE 13 Servicing Information Caution: • Pb free solder has a higher melting point than standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a high temperature soldering iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE Troubleshooting Air Conditioner Refrigeration cycle system In order to diagnose malfunctions, make sure that there are no electrical problems before inspecting the refrigeration cycle. Such problems include insufficient insulation, problem with the power source, malfunction of a compressor and a fan.
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE 1. Relationship between the condition of the air conditioner and pressure and electric current Cooling Mode Heating Mode Condition of the air conditoner Low Pressure High Pressure Electric current Low Pressure High Pressure...
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE 13.3. Remote Control • Remote Control Reset When the batteries are inserted for the first time, or the batteries are replaced, all the indications will blink and the remote control might not work.
Page 25
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE 15 Exploded View (Indoor Unit) 15.1. CS-E15DKEW Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
Page 26
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE 15.2. CS-E18DKEW CS-E21DKES Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.
Page 27
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE 16 Replacement Parts List (Indoor Unit) 16.1. CS-E15DKEW REF. NO. PART NAME & DESCRIPTION QTY. CS-E15DKEW REMARKS CHASSY COMPLETE CWD50C1431 FAN MOTOR CWA981149 CROSS FLOW FAN COMPLETE CWH02C1031 BEARING ASS’Y CWH64K007 SCREW - CROSS FLOW FAN...
Page 28
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE 16.2. CS-E18DKEW CS-E21DKES REF. NO. PART NAME & DESCRIPTION QTY. CS-E18DKEW CS-E21DKES REMARKS ← CHASSY COMPLETE CWD50C1382 ← FAN MOTOR CWA981149 ← CROSS FLOW FAN COMPLETE CWH02C1010 ← SCREW - CROSS FLOW FAN CWH4580304 ←...
CS-E15DKEW CU-E15DKE / CS-E18DKEW CU-E18DKE / CS-E21DKES CU-E21DKE 17 Exploded View (Outdoor Unit) 17.1. CU-E15DKE CU-E18DKE CU-E21DKE Note: The above exploded view is for the purpose of parts disassembly and replacement. The non-numbered parts are not kept as standard service parts.