4. No draining
Check if the E lectro-magnet iron acts?
voltage of the two ends of
of the two ends of the output
of the com puter sequencer.
Replace the computer
5. Keep filling water
Open the water faucet with out
swit ching on the power.
If the water can fill into
the water inlet valve
Switch on the power. Do not
push the "Start/Pause" button.
If the water can fill into
the water inlet valve
Check if the wire connecting
the computer board to the
water level s witch is bad?
Selec t "low " water leve l
and start the mac hine to
check if the gas cell
Check if the gas guide sys tem
Replace the water level switch.
Set rinse or spin.
Start the machine.
No
Measu re the
the E lectro-magnet ir on
No Exist
Measure the voltage
No Exist
sequencer.
No
No
No
has water?
No
is blocked?
No
Trouble-shooting
Roll up normally
Check the drain system like
the drain valve etc.
Exist
Re place the Electro-magnet ir on
Exist
Replace the wire unit.
At this time check if the Electro-magnet iron
works normally.
Yes
Replace the water inlet valve.
Yes
Replace the computersequencer.
At this time please check if the
water inlet valve is well.
Yes
Replace the wire unit.
Yes
It leaks gas. Please check and
repair the gas guide system.
Please smear 801 glue in installation
of the connectingpipe.
Please smear 801 glue in installation
of the gas cell cover.
Yes
Clear various factors like
the foreign Materials.
Blow from the connecting pipe to the
water level sensor and gas cell to see
if there's blocking.
T able