(2) Points of attention in assembly:
Fix the wiring in the control panel seat to its original position. Do not make it touch sharp
corner and mobile position. The space surrounding the computersequencer is rather narrow.
Please dispose it carefully and do not make the wire squeezed into the gapbetween the front
control board and the control panel seat.
When installing control panel seat to cabinet, please check if it is correct .
<2> The cabinet and outer tub component
(1) Method of disassembling
a. Loosen the two motor bolt unit to dismantle the motor. To adjust the tension of the belt, loosen
the bolts and move the motor left and right.
b. Loosen the four fastening screws to dismantle the Transisting guard shield.
c. Loosen the two fastening bolts and dismantle the axis to dismantle the Electro-magnet iron.
d. In dismantling the drain valve, first loosen the screws, then rotate combinationpart with the
drain hose, overflow hose and outer tub slowly to make it loose. Then dismantle the drain valve.
e. In dismantling the inner tub, first take off the outer tub cover, then dismantle the pulsator, finally
dismantle the inner tub. Handle with care when taking the inner tub off from the outer tub.
(2) Points of attention in assembly
In installation of the drain valve, please smear a pieceof 801 glue at the connectionpart
between the drain valve and outer tub and between the overflow hose and drain hose to
guarantee that the drain valve will not leak.
T ake care not to scratch the cabinetand influence the appearanceof the machine.
In fastening the screws, make it tight without sliding.
Key Points in Installa tion, Adjustment and Disassembly