Haier XQJ60-31 Service Manual page 12

Hide thumbs Also See for XQJ60-31:
Table of Contents

Advertisement

2. Key points
in Disassembly
Points of attention in maintenance
(1) General attention
Be sure to pull off the power plug in disassembly or maintenance.
The wiring between the conductionwires mostly adopts AMP terminal. Keep the terminal in
good condition during dismantling or maintenance.
In inserting the conducting wires, be sure to plug the pins to the root and make it hard to be
pulled out.
If welding is needed,be careful not to touch the plastic or other insulation parts with the iron.
When connectingthe wires, be sure to keep the wire away from the mobile parts like the belt,
radiating pulley and jib etc., and the sharp protruding parts and the parts with high temperature
(motor). Connect and fix the wires as per their original mode.
If there's metal object at the wire fixing point, be sure to insulate with insulation materials.
Retain the dismantled screws for future usage in installation.
(2) Points of attention in usage of electric components
In case that the power is on, the earthing circuit of the computersequencer can have 220V
voltage to earth. T ake care not to get electric shock.
Store the computersequencer and driver under 4 -30 . Avoid direct sunlight.
In trouble-shooting, it may require hot-line work. Please be extremely careful to avoid electric
shock.
<1>Thepart of control panel seat
(1) Method of opening the control panel
a. Open the back cover. Loosen the two locking belt fixed on the cabinet (used in inner wiring),
to loosen the inner wiring.
b. Loosen the four screws used to install the control panel seat , lift the control panel from
rear to up forwards to dismantle it from the cabinet. Then move it forwards several times to
pull the control panel seat to the rear side.
Attention:
Do not lift the control panel seat by force, otherwise the control rod may get transformed,
and the jointer part of the connecting pipe of the water level switch may be loosened,
or the connectingpipe may be broken and leak gas.
After opening the control panel seat, hold it with one hand or lean it on supporter like the wall.
Do not put it down. Otherwise it may pull the wire unit and connectingpipe.