3- INSTALLATION

3.1. OUTDOOR UNIT
(1) Install de outdoor unit in a place where it will be free from
being dirty or getting by rain as much as possible.
(2) During heating operation, drain water flows from the
outdoor unit. Therefore, install the outdoor unit in a place
where the drain water flow will not be obstructed. (Heat pump
model only).
(3) Do not place animals and plants in the path of the warm
air.
(4) Take the air conditioner weight into account and select a
place where noise and vibration are less.
(5) Select a place so that the warm air and noise from the air
conditioner do not disturb neighbours.
(6) Provide the space so that the air flow is not blocked. Also
for efficient operation, leave open three or the four directions
front, rear and both sides.
(7) When the outdoor unit will be exposed to strong wind,
fasten it with bolts at the places indicated by the arrows.
(8) When installing the drain pipe, plug another hole () in the
bottom of the outdoor unit with drain cap so there is no water
leakage.
PIPE DETAILS
3.3 Pipe Length
ORIGIN
Models
Load R-407C (kg)
Lines ('')
Cool
Heat
Gas
5/8"
050
1,7
2,0
---
5/8"
065
1,6
1,9
3/4"
3/4"
085
2,3
2,6
7/8"
3/4"
105
2,8
3,55
7/8"
3/4"
105T
2,8
3,55
7/8"
3/4"
130
3,8
4,2
7/8"
7/8"
180*
--
6,0
7/8"
1-1/8" 5/8"
230*
--
8,4
1-3/8" 5/8"
(1) It isn't necessary to isolate this line of liquid.
(* Without loading, value for 7.5 m. Model 180: 120 g/m; Model 230: 200 g/m)
Option
DISTANCIE EN LINEALS m.
15 m (4 curves)
20 m (6 curves)
Liq. % Aprox. R-407C
Oil % Aprox. R-407C
(g)
(g)
3/8"
99
250
---
98
---
---
---
---
---
3/8"
98
250
---
96
3/8"
100
300
---
99
3/8"
100
300
---
97
3/8"
102
300
---
101
3/8"
97
300
---
95
3/8"
101
300
---
100
3/8"
97
300
---
95
3/8"
101
300
---
100
1/2"
96
500
---
93
1/2"
102
500
---
100
1/2"
96
900
---
93
1/2"
102
900
---
100 1.500
97
1.500
---
95
(1)
102
1.800
---
101
(1)
3.2 Pipe connection
Installation Details
Type A height: Outdoor Unit above Indoor Unit.
Type B height: Outdoor Unit below Indoor Unit.
(1) Auxiliary siphons every 7 m.
NOTE:
In vertical layouts always place an oil trap (small siphon) at the
beginning of the vertical stretch. In the case of the heat pump
and with the outdoor unit below the indoor unit place siphons
every 7 m.
30 m (8 curves)
Oil % Aprox. R-407C Oil % Aprox. R-407C
(g)
(g)
(g)
(g)
400
---
96%
800
20
---
---
---
---
---
400
---
92
800
---
500
---
97
800
20
500
---
94
800
20
500
---
99
900
20
500
---
92
800
20
500
---
98
900
20
500
---
91
800
20
500
---
98
900
20
850
20
88
1.500 50
900
20
97
1.500 50
1.500
20
88
2.700 50
20
97
2.700 50
2.500
---
92
4.500 50
3.000
---
99
5.400 50
50 m (6 curves)
Max. Height (m)
Oil
Over
Under
(g)
(g)
IU
IU
92
1.500
50
45
20
---
---
---
87
1.500
50
45
20
94
1.500
50
89
1.500
50
45
20
96
1.600
50
85
1.500
50
45
20
94
1.600
50
85
1.500
50
45
20
94
1.600
50
80
2.800 100
45
20
91
2.900 100
80
5.100 100
45
20
91
5.100 100
87
8.500 100
45
20
97
10.200 100
11