Saunier Duval SDH 10-051 NK Installation Manual

Saunier Duval SDH 10-051 NK Installation Manual

Cassette / floor-ceiling / ducted units 2011
Table of Contents

Advertisement

Installation Manual

CASSETTE / FLOOR-CEILING / DUCTED UNITS
SDH 10-051 NK
SDH 10-066 NK
SDH 10-090 NK
SDH 10-105 NK
SDH 10-130T NK
SDH 10-051 NF
SDH 10-066 NF
2011
SDH 11-050 ND
SDH 11-065 ND
SDH 11-090 ND
SDH 11-105 ND

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDH 10-051 NK and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Saunier Duval SDH 10-051 NK

  • Page 1: Installation Manual

    Installation Manual CASSETTE / FLOOR-CEILING / DUCTED UNITS SDH 11-050 ND SDH 10-051 NK SDH 11-065 ND SDH 10-066 NK SDH 11-090 ND SDH 10-090 NK SDH 11-105 ND SDH 10-105 NK SDH 10-130T NK SDH 10-051 NF SDH 10-066 NF...
  • Page 2: Table Of Contents

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual CONTENTS CONTENTS INSTALLATION OF THE FLOOR-CEILING INDOOR UNIT ...22 yOUR SAFETy ..............3 10.1 General Warnings ............22 Symbols used ..............3 Correct use of the unit ............3 10.2 Mounting of the indoor unit ..........22 10.2.1 Preparing indoor unit installation .........22 EXTREME OPERATING CONDITIONS .........3 10.2.2 Floor installation ............22...
  • Page 3: Your Safety

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 1 YOUR SAFETY / 2 EXTREME OPERATING CONDITIONS 1 YOUR SAFETY 2 EXTREME OPERATING CONDITIONS SyMBOLS USED This unit has been designed to operate within the range of temperatures indicated on Figure .1. Ensure that these ranges are not exceeded.
  • Page 4: Identification Of The Unit

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 3 IDENTIFICATION OF THE UNIT / 4 DECLARATION OF CONFORMITY / 5 DESCRIPTION OF THE UNIT 3 IDENTIFICATION OF THE UNIT 5 DESCRIPTION OF THE UNIT This manual is valid for the Split Cassete, Floor-Ceiling and This unit is comprised of the following elements: Ducted series.
  • Page 5: Cassette Indoor Unit

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 5 DESCRIPTION OF THE UNIT CASSETTE INDOOR UNIT Electrical wiring Liquid and gas Fig. 5.2 Dimensions of the Indoor Unit 10-051 NHKI. Electrical wiring Liquid and gas Fig. 5.3 Dimensions of the Indoor Units 10-066 NHKI, 10-090 NHKI, 10-105 NHKI and 10-130 NHKI.
  • Page 6: Floor-Ceiling Indoor Unit

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 5 DESCRIPTION OF THE UNIT 5.2 FLOOR-CEILING INDOOR UNIT Electrical wiring Fig. 5.4 Dimensions of the Indoor Units. MODEL 10-051 NHKI 10-066 NHKI Table 5.2 Dimensions (mm) and Weights. 5.3 DUCTED INDOOR UNIT Fig.
  • Page 7 Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 5 DESCRIPTION OF THE UNIT Air filter Electrical wiring Fig. 5.7 Position size of desensional ventilation opening. Electrical wiring Fig. 5.8 Distances between mounting hooks. Outline dimensions Air outlet opening size Air return opening size Mounting hooks MODEL...
  • Page 8: Outdoor Unit

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 5 DESCRIPTION OF THE UNIT 5.4 OUTDOOR UNIT The outdoor unit ensures that the absorbed air is released to the outside from the room during operation in cooling mode and that the heat introduced into the room during operation in heat pump mode is taken from the outside.
  • Page 9: Remote Controller

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 5 DESCRIPTION OF THE UNIT 5.5 REMOTE CONTROLLER The remote control allows using the unit. NOTE! Ducted units operate with the wiring control SDSC-01. Consult user manual of it for the installation of the control to the ducted unit through the signal receiver.
  • Page 10: Technical Specifications Cassettes

    Max. height IU under OU Max. height OU under IU Chargeless length Additional charge per meter Table 5.6 Technical specifications. NOTE! As part of its policy for ongoing improvements of its products, Saunier Duval reserves the right to modify these specifications without prior notice.
  • Page 11: Technical Specifications Floor-Ceilings

    Max. height IU under OU Max. height OU under IU Chargeless length Additional charge per meter Table 5.7 Technical specifications. NOTE! As part of its policy for ongoing improvements of its products, Saunier Duval reserves the right to modify these specifications without prior notice.
  • Page 12: Technical Specifications Ducted

    Max. height IU under OU Max. height OU under IU Chargeless length Additional charge per meter Table 5.8 Technical specifications. NOTE! As part of its policy for ongoing improvements of its products, Saunier Duval reserves the right to modify these specifications without prior notice.
  • Page 13: Transport

    Ensure that this unit is installed by authorised personnel. The To avoid this: personnel authorised by Saunier Duval must be suitably qua- - Use transport and lifting gear with suitable load lified and able to install the unit correctly.
  • Page 14: General Installation Diagram

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 8 INSTALLATION 8.3 GENERAL INSTALLATION DIAGRAM WARNING! Danger of breakdowns or malfunction. Observe the minimum clearences indicated in Figure 8.1, 8.2, 8.3 and 8.4. Fig. 8.2 Minimum assembly distances: cassettes. MODEL 10-051 NHKI 1000 1000...
  • Page 15: Installation Of The Cassette Indoor Unit

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 9 INSTALLATION OF THE CASSETTE INDOOR UNIT 9.2 SELECTING THE ASSEMBLy LOCATION 9 INSTALLATION OF THE CASSETTE INDOOR UNIT Danger of personal injury and material damage from 9.1 GENERAL WARNINGS collapse! Ensure that the ceiling and the fixing elements are able Danger of physical damage! to withstand the weight of the indoor unit.
  • Page 16: Recommended Installation Process

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 9 INSTALLATION OF THE CASSETTE INDOOR UNIT 9.3 RECOMMENDED INSTALLATION PROCESS 9.4.2 LAyING OF THE CONDENSED WATER PIPE NOTE! It is recommended carrying out the installation in the follo- The indoor unit is fitted with a condensed water removal wing order: pump.
  • Page 17: Installation Of The Refrigerant Pipes

    Applying excessive force without correctly centring can damage the thread and cause a reduction in the water tightness in the join. Note! In specialised dealers you will find refrigerant pipes which are thermally insulated as a Saunier Duval accessory.
  • Page 18: Installation Of The Fresh Air

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 9 INSTALLATION OF THE CASSETTE INDOOR UNIT 9.6 INSTALLATION OF THE FRESH AIR INSTALLATION 1 Drainage pipe The following models are fitted with a fresh air inlet: 10-066 NHKI, 10-090 NHKI, 10-105 NHKI, 10-10 NHKI. Refrigerant pipe Air inlet hole INSTALLATION 2...
  • Page 19: Indoor Unit Assembly In The Ceiling

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 9 INSTALLATION OF THE CASSETTE INDOOR UNIT 9.7 INDOOR UNIT ASSEMBLy IN THE CEILING NOTE! The indoor unit is fixed to the ceiling using hooks and hanging bars (threaded varilla M10), with its corresponding nuts, locknuts and washers.
  • Page 20: Connections

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 9 INSTALLATION OF THE CASSETTE INDOOR UNIT 9.8 CONNECTIONS 9.9.1 PANEL CONNECTIONS • Carefully remove the insulation of the flared connections in the indoor unit. • Connect the refrigerant pipes and the condensed water hose to the corresponding pipes and installation drain.
  • Page 21: Installation Of The Distribution Duct

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 9 INSTALLATION OF THE CASSETTE INDOOR UNIT 9.10 INSTALLATION OF THE DISTRIBUTION DUCT Distribution duct Distribution duct Distribution duct Fresh Air Distribution duct Two way One way Fig. 9.7 Installation of the distribution duct. NOTE! Max.length: 2m The louver below the distribution duct must be sealed.
  • Page 22: Installation Of The Floor-Ceiling Indoor Unit

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 10 INSTALLATION OF THE FLOOR-CEILING INDOOR UNIT The drain hose can be connected to the drain port either left INSTALLATION OF THE FLOOR-CEILING INDOOR UNIT of right side. 10.1 GENERAL WARNINGS WARNING! Danger of breakdowns or malfunction.
  • Page 23: Ceiling Installation

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 10 INSTALLATION OF THE FLOOR-CEILING INDOOR UNIT Reset the bolts as shown below. • Drilling for piping Select piping directions. Apply the indoor unit to hangers. Indoor unit 5/16" to 1/" (8 to 1 mm.) Rear (install...
  • Page 24: Installation Of The Refrigerant Pipes

    Applying excessive force without correctly centring can damage the thread and cause a reduction in the water tightness in the join. NOTE! In specialised dealers you will find refrigerant pipes which are thermally insulated as a Saunier Duval accessory.
  • Page 25: Installation Of The Ducted Indoor Unit

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 11 INSTALLATION OF THE DUCTED INDOOR UNIT 11.2 SELECTING THE ASSEMBLy LOCATION 11 INSTALLATION OF THE DUCTED INDOOR UNIT Danger of personal injury and material damage from 11.1 GENERAL WARNINGS collapse! Ensure that the ceiling and the fixing elements are able Danger of physical damage! to withstand the weight of the indoor unit.
  • Page 26: Installation Of The Unit

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 11 INSTALLATION OF THE DUCTED INDOOR UNIT 11.3 INSTALLATION OF THE UNIT 11.6 POSSIBILITy OF DESCENSIONAL AIR DIRECTION - Use the appropriate fasteners for each structure type - Remove the descensional ventilation panel and the air paying special attention to any possible transmission of return flange.
  • Page 27: Installation Of The Condensed Water Pipe

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 11 INSTALLATION OF THE DUCTED INDOOR UNIT 11.7 INSTALLATION OF THE CONDENSED WATER PIPE 11.7.2 LAyING OF THE CONDENSED WATER PIPE NOTE! 11.7.1 HANDLING THE CONDENSED WATER PIPE The indoor unit is fitted with a condensed water removal pump.
  • Page 28: Drainage Test

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 11 INSTALLATION OF THE DUCTED INDOOR UNIT 11.8 DRAINAGE TEST 11.9 INSTALLATION OF THE FRESH AIR - Check whether the drainpipe is unhindered. These ducted units have a joint for a fresh air: - Every new built house should have this test done before paving the ceiling.
  • Page 29: Static Pressure Curves

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 11 INSTALLATION OF THE DUCTED INDOOR UNIT 11.11 STATIC PRESSURE CURVES High speed High speed Medium speed Medium speed Low speed Low speed Air Flow Volume (m Air Flow Volume (m High speed High speed Medium speed...
  • Page 30: Installation Of The Refrigerant Pipes

    Applying excessive force without correctly centring can damage the thread and cause a reduction in the water tightness in the join. NOTE! In specialised dealers you will find refrigerant pipes which are thermally insulated as a Saunier Duval accessory.
  • Page 31: Installation Of The Outdoor Unit

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 12 INSTALLATION OF THE OUTDOOR UNIT 12 INSTALLATION OF THE OUTDOOR UNIT 12.1 SELECTING THE ASSEMBLy LOCATION WARNING! Outdoor units must be placed in accessible areas for subsequent maintenance and repair operations. Saunier Duval will not be responsible for any costs derived from incorrect positioning that prevents easy access.
  • Page 32: Connection Of The Refrigerant Pipes

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 12 INSTALLATION OF THE OUTDOOR UNIT 12.2 CONNECTION OF THE REFRIGERANT PIPES 12.3 CONNECTION OF THE PIPE FOR THE DRAINAGE OF THE CONDENSED WATER NOTE! Installation is easier if the gas suction pipe is connected Whilst the unit is running with the heat pump function, con- up first.
  • Page 33: Electric Wiring

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 13 ELECTRIC WIRING WARNING! 13 ELECTRIC WIRING Danger of breakdowns or malfunction. Ensure that the supplied power voltage is in the range 13.1 SAFETy PRECAUTIONS of 90% to 110% of the rated voltage. DANGER! WARNING! Danger of electric shock.
  • Page 34: Electric Connection Of The Indoor Unit

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 13 ELECTRIC WIRING 13.3 ELECTRIC CONNECTION OF THE INDOOR UNIT • Connect the line on the terminal strip of the indoor unit according to the corresponding wiring diagram (see WARNING! Figures). Danger of breakdowns or malfunction.
  • Page 35: Electric Connection Of The Outdoor Unit

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 13 ELECTRIC WIRING 13.4 ELECTRIC CONNECTION OF THE OUTDOOR UNIT WARNING! • Remove the protective covering in front of the electrical Danger of breakdowns or malfunction. If the fuse connections in the outdoor unit. on the PC board is blown please change it with type •...
  • Page 36: Preparation For Use

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 14 PREPARATION FOR USE NOTE! 14 PREPARATION FOR USE According to Regulation 842/2006/EC, the complete refrigerant circuit must be periodically checked for This consists of the following steps: leakage. Take the necessary actions to ensure these •...
  • Page 37: Start Up

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 14 PREPARATION FOR USE 14.3 START UP • Check the needle on the low pressure manometer: it should indicate -0.1 MPa (-76 cmHg). Fig. 14.5 Filling the installation. Legend 1 Two-way valve Fig.
  • Page 38: Troubleshooting

    CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 14 PREPARATION FOR USE Fig. 14.7 Protective covers. Legend 1 Service hole lid  Two and three-way valve covers • Connect the unit and run it for a few moments checking that it carries out its functions correctly (for more information see the user manual).
  • Page 39: Error Codes

    Installation Manual / CASSETTE - FLOOR-CEILING - DUCTED UNITS 15 ERROR CODES 15 ERROR CODES INDOOR UNITS 10-051 NHKI, 10-051 NHFI, 10-066 NHFI Malfunction Operation lamp Timer lamp Def/Fan lamp Alarm lamp Communication malfunction between in-outdoor unit LED Quick-flash Room temperature sensor malfunction LED1 Quick-flash Water-level alarm LED4 Quick-flash...
  • Page 40 CASSETTE - FLOOR-CEILING - DUCTED UNITS / Installation Manual 15 ERROR CODES OUTDOOR UNITS Display Content of malfunction or protection EEPROM Malfunction Communication malfunction between outdoor IC and indoor IC. Communication malfunction between outdoor IC and DSP Malfunction of out ambient temp. sensor Voltage protection of compressor PFC module protection (only for 1-phase models 090, 105 y 10) Top temperature protection of compressor...