Installing the Unit .....................................................................................................4 - 9
Before installing........................................................................................................................................ 4
Indoor unit location................................................................................................................................... 5
Water connections ................................................................................................................................... 7
Saunier Duval Clima, S.A. INSTALLATION MANUAL 035 AK 075 AK Page Technical Specifications ....................3 Installing the Unit .....................4 - 9 Before installing............................4 Select location ............................4 Indoor unit location........................... 5 Installation method..........................5 - 7 Drain pipework ............................7 Water connections ...........................
Page 2
Thank you very much for choosing our air conditioner! Please read this Owner’s Manual carefully before using your air conditioner. Notice: The outline of the air conditioner on the manual cover is only a sketch. Before you operate your air conditioner, please read the Important Safety Information Chapter first to avoid the air conditioner damage or any other accident caused by your mishandling.
2.- INSTALLING THE UNIT BEFORE INSTALLING It is advisable to place the unit close to the installation site without removing it from the packaging. Do not put heavy tools or weights on the packaging. Upon receipt the unit and the packaging must be checked for damage sustained in transit and if necessary, a damage claim must be filed with the shipping company.
Check the distance between the upper slab and false ceiling to ensure the unit will suit the distance. (Fig.4) MODEL A (mm) 035 AK 075 AK Ensure there is sufficient space around the unit to service it. See Fig.5 INSTALLATION METHOD Cassette Indoor Unit: Using the installation template open ceiling panels and install the suspension bolts as in Fig.6 below.
Page 6
Line up the unit to the supporting bars of the false ceiling tightening the nuts and counternuts of the threa- ded rods. After connection of the condensate drain piping and piping connections, check again that the unit is level. MODEL A (mm) 035 AK 075 AK...
Tighten the nuts on the suspended rods. MODEL A (mm) 035 AK 075 AK DRAIN PIPEWORK Indoor Unit: The unit is fitted with a condensate pump with a 500 mm lift. The unit is provided with 22 mm bore flexible hose 300 mm long.
Install the unit and components as far as practical (at least five metres away from the electromagnetic wave source). Install a noise filter if any harmful noise exists in the power supply. 075 AK 035 AK MOUNTING FRONT PANEL ASSEMBLY Remove return grille from front panel.
2.- INSTALLING THE UNIT 075 AK Fresh Air Renewal and Branch Ducting The side opening allows separate ductwork to be installed for outside air intake and branch ducting. See Fig.23 Cut and remove anti-condensate insulating material. Install your flanges and conduits to casing. Conduits can be flexible polyester with spring core or corruga-...