Saunier Duval Clima, S.A.
Installations Tips ...........................................................................................................3
Standard Parts..............................................................................................................3
Units Location......................................................................................................... 4 - 5
Pipe Lenght ..................................................................................................................5
Indoor Unit Installation............................................................................................ 6 - 7
Outdoor Unit Installation ....................................................................................... 8 - 11
Wiring Diagrams ................................................................................................. 12 - 15

INSTALLATION MANUAL

SDC 050 W
SDH 050 W
SDC 065 W
SDH 065 W
SDC 035 M2
SDH 050 M2
SDC 035 MP3
SDH 060 M2
SDC 050 M2
SDH 075 M2
SDC 050 MP3
SDH 100 M3
SDC 075 M2
SDC 090 M3
SDC 090 MP4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDC 050 W and is the answer not in the manual?

Questions and answers

Summary of Contents for Saunier Duval SDC 050 W

  • Page 1: Installation Manual

    Saunier Duval Clima, S.A. INSTALLATION MANUAL SDC 050 W SDH 050 W SDC 065 W SDH 065 W SDC 035 M2 SDH 050 M2 SDC 035 MP3 SDH 060 M2 SDC 050 M2 SDH 075 M2 SDC 050 MP3 SDH 100 M3...
  • Page 3: Standard Parts

    1- INSTALLATION TIPS The installation shall be made by authorised personal only. (1) For the room air conditioner to operate satisfactorily, install it as outlined in this installation manual. (2) Connect the indoor unit and outdoor unit with the room air conditioner piping and cords available stan- dard parts.
  • Page 4: Indoor Unit Dimensions

    2- UNITS LOCATION Decide the mounting position together with the customer as follows: 1. INDOOR UNIT (1) The inlet and outlet ports should not be obstructed , the air should be able to blow all over the room. (2) Do not install the unit where it will be exposed to direct sunlight. (3) Install the unit where connection to the outdoor unit is easy.
  • Page 5 MAXIMUM PIPING LENGTH & REFRIGERANT CHARGE PIPING MAX. HEIGHT REFRIGERANT Liquide Max. Lenght Over IU Down IU Charge(g) Max. Lenght SDC 050 W 5/8” 3/8” 25 m 15 m 1.500 g 10 m SDH 050 W 5/8” 3/8” 25 m...
  • Page 6: Indoor Unit Installation

    3- INDOOR UNIT INSTALLATION INSTALLATION PROCEDURE 2. CUTTING THE HOLE IN THE WALL FOR THE CONNECTING PIPING Install the air conditioner as follow: (1) Cut a 80 mm. diameter hole in the wall at the position INDOOR UNIT INSTALLATION shown below. (2) When cutting the wall hole at the inside of the installa The piping can be connected in the fi ve directions indi- tion frame, cut the hole at least 10 mm.
  • Page 7: Installing The Indoor Unit

    3- INDOOR UNIT INSTALLATION - Install the indoor Unit piping in the direction of the wall - Bend the connection piping at a bend radius of 70 mm. hole and bind the drain hose and pipe together with or more and install no more than 35 mm. from the vinyl tape.
  • Page 8: Outdoor Unit Installation

    4- OUTDOOR UNIT INSTALLATION PIPE CONNECTIONS MODEL Liquid 025 (C/H) WI 1/4” 3/8” 035 (C/H) WI 1/4” 1/2” 050 WI 3/8” 5/8” 065 WI 3/8” 5/8” 2- OUTDOOR UNIT INSTALLATION - Set the unit on a strong stand, install protective rubber pieces under it.
  • Page 9: Refrigerant Pipes

    4- OUTDOOR UNIT INSTALLATION - At the end of pump down, close the low pressure side gauge of the gauge manifold fully and stop the vacuum WARNING! pump. (1) When moving and installing the air conditioner, - Slowly loosen the valve stem of the 3- way valve. When do not mix gas other than the specifi ed refrige- the compound pressure gauge reading reaches 1- 2 rant (R-22) inside the refrigerant cycle.
  • Page 10 4- OUTDOOR UNIT INSTALLATION SDC/H 050 / 065 W SDC 035 M2 - SDC/H 050 M2 SDH 060 M2 SDH 075 M2 SDC 035 MP3 SDC 050 MP3...
  • Page 11 4- OUTDOOR UNIT INSTALLATION SDC 090 M3 SDH 100 M3 SDC 090 MP4...
  • Page 12: Wiring Diagrams

    5- WIRING DIAGRAMS CABLE SECTION MODEL POWER INPUT Ud. A Ud. B Ud. C Ud. D SDC/H 050/065 W SDC 035 M2 SDC 035 MP3 SDC 050 M2 SDC 050 MP3 SDH 050/060 M2 SDC/H 075 M2 SDH 090 M3 SDH 090 MP4 SDH 100 MP3 The installation of electric assault to the machine, it should have a switch...
  • Page 13 5- WIRING DIAGRAMS SDC 035 MP3 SDC 050 M2 SDC 050 MP3...
  • Page 14 5- WIRING DIAGRAMS SDC 075 M2 SDH 050 / 060 / 075 M2 SDC 090 M3...
  • Page 15 5- WIRING DIAGRAMS SDC 090 MP4 SDH 100 M3...