3.4 INSTALLATION - ELECTRICAL REQUIREMENTS
WARNING: THIS APPLIANCE MUST BE EARTHED. IT IS SUITABLE FOR A.C.
SUPPLY ONLY. DISCONNECT THE ELECTRICAL SUPPLY BEFORE REMOVING
THE TERMINAL COVER. INSTALLATION MUST BE IN ACCORDANCE WITH
THE CURRENT IEE WIRING REGULATIONS.
1. The unit is supplied fitted with a 1.0m 3 core 1.5mm
electicity supply should be fused 13 Amp for a 3kW model and be via a
double pole isolating switch with a contact separation of at least 3mm in
both poles. Refer to the schematic wiring diagram below.
2. The wires are colour coded as follows:
Green and Yellow
Brown
Blue
FIGURE 05: WIRING DIAGRAM
L
N
10
EARTH
LIVE
NEUTRAL
TERMINAL
THERMAL
BLOCK
CUT-OUT
ELEMENT
PLATE
EARTH
POST
EARTH LINK
CONTAINER
(L)
(N)
RED
ELEMENT
BLACK
TO
flexible cable. The
2
THERMOSTAT
RED
RED
NEON