  • Page 2 INTRODUCTION Thank you for purchasing a Heatrae Sadia Supreme water heater. This boiling water heater is manufactured to the highest standards and has been designed to meet all the latest relevant safety specifications. This Heatrae Sadia water heater must be installed (sections 1-6, p4-9), commissioned (section 7, p10) and maintained (sections 8-9, p11-13) by a competent person.
  • Page 3: Component Checklist

    Rated pressure 0MPa (0 bar) Minimum supply pressure 0.05MPa (0.5 bar) Maximum supply pressure 1.0MPa (10bar) Enclosure rated IPX-2 A-weighted sound pressure level is below 70 dB Nominal commissioning times (minutes) to temperature ready Supreme 150SS Supreme 165SS Supreme 180SS...
  • Page 4: Important Installation Points

    1.0 IMPORTANT INSTALLATION POINTS 1.1 The Supreme stores and dispenses water at or close to boiling point at all times it is switched on. Due caution must be taken when choosing a location for the product to minimise misuse. Locate the unit over a draining board NOT over the sink or basin.
  • Page 5: Installation - Mounting

    2.0 INSTALLATION - MOUNTING 2.1 The Supreme must be vertically wall mounted using the bracket supplied. Special precautions may be required for the protection of children and/or infirm persons. 2.2 Figure.1, p6 details the outside dimensions of the Supreme unit. A template is supplied to aid positioning the heater.
  • Page 6 3.0 DIMENSIONS approx Figure 1 MODEL DIMENSIONS (mm) OUTLET INLET VENT CABLE ENTRY 150SS 165SS 180SS...
  • Page 7: Installation - Water Supply

    4.0 INSTALLATION - WATER SUPPLY 4.1 Select appropriate push fit connector for chosen entry position: B o t t o m e n t r y w a t e r - 1 5 m m x 1 5 m m 9 0 ° e l b o w . R e a r e n t r y w a t e r...
  • Page 8: Installation - Vent Pipe

    5.0 INSTALLATION - VENT PIPE 5.1 Select appropriate push fit connector for chosen entry position: Bottom entry vent 15mm x 15mm straight Rear entry vent 15mm x 15mm 90° elbow 5.2 Push the connector fully home (28mm engagement) onto the vent pipe connection.
  • Page 9: Installation - Electrical Requirements

    6.0 INSTALLATION - ELECTRICAL REQUIREMENTS 6.1 This appliance must be earthed. 6.2 The installation, supply cable and circuit protection must conform to the latest BS7671 ‘Requirements for electrical installations’ (IEE Wiring Regulations). 6.3 The appliance must only be connected to a 230/240 V ac supply. A double pole isolating switch, with a contact separation of at least 3mm in both poles, must be incorporated in the electrical supply.
  • Page 10 7.0 COMMISSIONING 7.1 The electronic control system of the Supreme has a self commissioning and calibration function. Once the heater is installed and all services have been connected the unit should require no further adjustment before use. 7.2 Check that all electrical, water and vent pipe connections have been made and are secure.
  • Page 11: Maintenance

    8.0 MAINTENANCE NOTE: Maintenance must be carried out by competent persons. Competent - i.e. trained, experienced, qualified. Disconnect the electrical supply before removing the cover. WARNING: Electronics control by switching ‘N’ (neutral), in some instances neutral terminations will be at 230 volts with respect to earth. 8.1 The Supreme incorporates an electronic scale conditioning function which will reduce the rate of scale deposition in hard water areas.
  • Page 12: Fault Finding

    9.0 FAULT FINDING Your Heatrae Sadia Supreme should give trouble-free operation. However should a fault occur, the table below should allow most faults to be identified. Fault finding should only be carried out by a competent person. SYMPTOM POSSIBLE CAUSE...
  • Page 13 A fault is detected Call an engineer gives 3 flashes and the unit shuts down For any faults that cannot be identified using the Fault Finding chart, please contact Heatrae Sadia Service Department, telephone 0344 871 1535, fax 0344 871 1528, e-mail customer.support@heatraesadia.com...
  • Page 14: Spare Parts

    Do not replace with parts not recommended by Heatrae Sadia - this will invalidate your guarantee and may render the installation dangerous. Element assembly 2.5kW (incorporating start dry cutout) ....95 606 952 Element assembly sealing gasket ............
  • Page 16: User Instructions

    11.0 USER INSTRUCTIONS 11.1 Once installed the filling and heating cycles of the Supreme are completely automatic. 11.2 To dispense water, a suitable container having been placed under the outlet spout, the tap handle should be pulled down and towards (or pushed away from) the user. The water dispensed will at all times be boiling or close to boiling point so due caution must be taken when using the product, especially if it is likely to be used by children, aged or infirm persons.