3.0 INSTALLATION

Warning: this appliance must be earthed. It is suitable for a.c. supply only.
Electrical installation must be carried out by a competent electrician and be in
accordance with the latest IEE wiring regulations
Warning: Do not connect any pressure-relief device to the vent pipe of this
water heater.
Warning: The outlet acts as a vent and must only be connected to a fitting
recommended by the manufacturer. It must not be connected to a tap.
1.
National Wiring rules may contain restrictions concerning the installation of
these units in bathrooms.
2.
The unit should be vertically wall mounted using the wall bracket and levelling
feet supplied (see Section 3.1 INSTALLATION - WALL MOUNTING). The inlet
and outlet water connections must always be on the bottom of the unit.
3.
Enough space should be left below and at the top above the unit for pipe
connections. Refer to Diagram 1 and the Dimensions Table to determine a
suitable position for the heater.
4.
NOTE: Ensure that the wall can support the full weight of the unit (see
TECHNICAL SPECIFICATIONS) and that there are no hidden services (electricity,
gas, or water) below the surface of the wall.
5.
DO NOT install where the unit may freeze.
6.
Refer to the section IMPORTANT INSTALLATION POINTS to determine which
valves and accessories are required.
7.
The water connections are 15mm diameter copper tubes suitable for compression
fittings. Do not use solder joints as this will damage the heater.
8.
The INLET is marked BLUE, the OUTLET is marked RED. It is recommended that
a WRAS Listed isolating valve be fitted on the cold water supply to the heater.
9.
Plumbers Paste must not be used as it can impair the operation of components.
B3M/C3M
B3
C3
30.0
50.0
50
77
S
M
D
D
30.6
34.5
603
1489
2.940
7.060
60°C
See section 2 to 6
5