Use
CE1N2203en
24.04.2008
Weekday / weekend
room temperature controller
Heating applications
Mains-independent, battery-operated room temperature controller featuring
user-friendly operation, easy-to-read display and large numbers
Self-learning two-position controller with PID response (patented)
Operating mode selection:
- 7-day (weekday / weekend) automatic mode.
with max. 3 heating phases
- Continuous comfort mode
- Continuous energy saving mode
- Frost protection
- Exception day (24 hour operation) with max. 3 heating phases
A separate temperature setpoint can be entered in automatic mode and for
the exception day for each heating phase
To control a heating zone
Room temperature control in:
• Single-family and vacation homes
• Apartments and offices
• Individual rooms and professional office facilities
• Commercially used spaces
Control for the following equipment:
• Magnetic valves of an instantaneous water heater
• Magnetic valves of an atmospheric gas burner
• Forced draught gas and oil burners
• Electrothermal actuators
• Circulating pumps in heating systems
• Electric direct heating
• Fans of electric storage heaters
• Zone valves (normally open or normally closed)
2
203
REV17..
Building Technologies

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the REV17 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siemens REV17 Series

  • Page 1 Weekday / weekend REV17.. room temperature controller Heating applications • Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large numbers • Self-learning two-position controller with PID response (patented) • Operating mode selection: - 7-day (weekday / weekend) automatic mode. with max.
  • Page 2 The easily accessible battery compartment allows for easy exchange of two 1.5 V alkaline batteries, type AA. The base with terminal block provides lots of space to connect the wires. Display and operating elements 2 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 3 The unit first displays queued error messages followed by important information (e.g. time switch programs, etc.). Plus button Increase values, set time, or make a selection. 3 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 4 Start of absence / holiday Temperature setpoint during absence / holiday End of absence / holiday Temperature setpoint at active remote control Slider position RUN allows for closing the cover 4 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 5 1…5 and weekend days Time switch 6…7. As a result, you need to adapt the switching times and room temperatures only once for each block. Switching pattern Blocks 5 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 6: Remote Control

    Proceed as follows to enter your settings: Set slider to position 18 (temperature for active remote control): Press to set the desired temperature for active remote control. RUN Return the slider to position RUN. 6 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 7: Technical Features

    DIP switch ON: Temperature display in °F. °C or °F: DIP switch OFF: Temperature display in °C (factory setting). DIP switch 3 Press the DIP switch reset button to save the settings. 7 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 8 RUN position during these 10 minutes. Siemens recommends to set the desired settings upon startup, install the REV..DC in the desired location, and not carry out any actions on the REV..DC for the next 10 minutes.
  • Page 9: Functional Check

    • It is possible that in heating mode the room temperature is higher than the set temperature setpoint. e) Set the temperature setpoint for operating mode “Continuous comfort mode“ to the desired value. f) Select the desired operating mode. 9 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 10: User-Defined Settings

    • Recalibrate the temperature sensor (see "Sensor calibration") if the displayed room temperature does not match the room temperature measured. Notes This is a software class A controller designed for use at a normal degree of pollution. 10 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 11 2M2 as per IEC 60 721-3 Weight Excl. packaging 0.29 kg Color Housing RAL9003 signal white Base RAL7038 gray Size Housing with base 90 x 134.5 x 30 mm 11 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 12: Connection Diagrams

    Thermal reset limit thermostat 3-port valve with manual adjustment Manual reset safety limit thermostat Magnetic valve Circulating pump Three-port valve with actuator REV17.. room temperature controller Y4 Two-port valve with actuator 12 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...
  • Page 13 Dimensions 134,5 83,5 ©2008 Siemens Switzerland Ltd Subject to change 13 / 13 Siemens Room temperature controller REV17.. CE1N2203en Building Technologies 24.04.2008...