MTU 20 V 4000 G43 Operating Instructions Manual page 90

Hide thumbs Also See for 20 V 4000 G43:
Table of Contents

Advertisement

301 – AL Timing Cylinder A1
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or
extremely high.
302 – AL Timing Cylinder A2
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or
extremely high.
303 – AL Timing Cylinder A3
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or
extremely high.
304 – AL Timing Cylinder A4
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or
extremely high.
305 – AL Timing Cylinder A5
Cause
Time-of-flight measuring fault of
injector: Time-of flight measured
value extremely low or
extremely high.
90 | Troubleshooting | M015715/03E 2013-01
ZKP-Number: 1.8004.500
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 134).
ZKP-Number: 1.8004.501
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 134).
ZKP-Number: 1.8004.502
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 134).
ZKP-Number: 1.8004.503
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 134).
ZKP-Number: 1.8004.504
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 134).