3.3 20 V 4000 Gx3 engine data: Continuous operation, variable
3B, optimized exhaust emissions (EPA2)
Explanation
Abbr.
Meaning
DL
Ref. value: Continuous power
BL
Ref. value: Fuel stop power
A
Design value
G
Guaranteed value
R
Guideline value
L
Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N
Not yet defined value
-
Not applicable
X
Applicable
Reference conditions
Engine model
Application group
Intake air temperature
Charge-air coolant temperature
Raw-water inlet temperature
Barometric pressure
Site altitude above sea level
Power-related data (power ratings are net brake power to ISO 3046)
Number of cylinders
Rated engine speed
Continuous power ISO 3046 (10% overload capability,
design power DIN 6280, ISO 8528)
General conditions (for max. power)
Number of cylinders
Intake depression (new filter)
Intake depression, max.
Exhaust overpressure
Exhaust overpressure, max.
20V
4000G43
°C
°C
°C
mbar
1000
m
100
A
rpm
1800
A
kW
2490
A
mbar
L
mbar
A
mbar
L
mbar
M015715/03E 2013-01 | Technical Data | 35
20V
20V
4000G83
4000G83
L
3B
3B
3B
25
25
25
45
45
45
-
-
1000
1000
100
100
20
20
20
1800
1800
2740
3010
20
20
20
15
15
15
50
50
50
30
30
30
85
85
85
-