Changing The Master Code - CDVI GALEO Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION MANUEL
GALEO
Illuminated Weatherproof Keypad with remote electronics
7] PROGRAMMING
DEFAULT VALUES
- Without codes.
- Illumination time: 10 seconds.
- Relay release time: 1 second.
- Code length: 5-digit.
- Master Code: 1 2 3 4 5.
- Programming security time :
120 secondes.
- Code length for sub master code:
Version 1 relay (Group 1) =
A and B,
Version 2 relays (Group 2) =
1 and 3
Version 3 relays (Group 3) =
4 and 6.
A. RESET MASTER CODE
AND USER CODES
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm entry
in programming mode.
2. Press A6 to reset the Master Code
and the User codes.
One beep is emitted. Press on A and B to confi rm
reset of all memory of the keypad. Wait for two
beeps. The master code is restored to its default
value 1 2 3 4 5 and all the User codes are deleted
from the keypad. Once the reset is completed then
the keypad returns to a stand-by
operating mode.
OR
1. Cut the power. Put the jumper on P2.
2. Put the power back.
Wait approximately 3 seconds.
Two beeps are emitted to confi rm reset
of the keypad. Remove P2 jumper. The master
code is restored to its default value 1 2 3 4 5
and all the User codes are deleted from
the keypad.
B. SETTING CODE LENGTH
AUDIBLE SIGNAL:
The buzzer indicates different
audible signals. It can be turned
off by cutting the ST1 wire on the
remote controller
1 short beep: Keypad powered
1 long beep: data computing in
programming or access granted
2 short beeps: Enter or Exit from
programming
4 short beeps: data computing
error.
CODE LENGTH
The master code and the User codes
can be of 4 or 5-digit in length.
All the keypad keys can be used to
1. Enter the master code twice.
(1 2 3 4 5 default value master code).
2 beeps are emitted to confi rm entry
in programming mode.
2. Press A4 to program the code length.
One beep is emitted. Press 4 or 5 for the digit
code. One beep is emitted to confi rm programming
of the code length.
3. Press A5 to modify the master code.
One beep is emitted. Enter the new 4 or 5-digit
master code. One beep is emitted to confi rm pro-
gramming of the new master code.
4. Press B to exit from programming mode.
2 beeps are emitted to confi rm that the keypad
is in stand-by operating mode.
4 beeps indicate a data computing error.
C. CHANGING THE MASTER CODE
The master code is used only to enter
in programming mode.
1. Enter the master code twice.
(1 2 3 4 5 default value master code). 2 beeps
are emitted to confi rm entry in programming mode.
program a code. The master code and
the Pin code can be of 4 or 5-digit code.
The master code CAN NOT be used as
a PIN code (User Pin code). The master
code CAN NOT be used as a PIN code
(User Pin code). To delete a specifi c
User pin Code replace it by 0000 if code
length is 4-digit format or replace it by
00000 if the code is in 5-digit format.
P2 JUMPER:
Reset master code
and user codes.
P3 JUMPER:
modifi cation of individual
code by the user.