Maintenance; Maintenance Schedule - Westinghouse WH3250 Owner's Manual

Hide thumbs Also See for WH3250:
Table of Contents

Advertisement

Available languages

Available languages

MAINT NAN
MAINTENANCE
Before performing maintenance
on the generator, review Safety on
page 7and the following
safety
messages.
Avoid accidentally
starting the
generator during maintenance
by
removing
the spark plug boot from
the spark plug. For electric
start
generators, also disconnect
the battery
wires from the battery (disconnect
the
black negative (-) wire first) and place
the wires away from the battery posts
to avoid arcing.
Allow hot components to cool to
the touch prior to performing
any
maintenance
procedure.
Internal pressure can build in the
engine crankcase while the engine
is running. Removing
the oil fill plug/
dipstick
while the engine is hot can
cause extremely hot oil to spray out
of the crankcase
and can severely
burn skin. Allow engine oil to cool for
several minutes
before removing the oil
fill plug/dipstick.
Always perform maintenance
in a well-
ventilated area. Gasoline
fuel and fuel
vapors are extremely
flammable
and
can ignite under certain conditions.
Table 1 : Maintenance
Schedule
- Owner Performed
@
Avoid skin contact with engine oil or
gasoline.
Prolonged skin contact with
engine oil or gasoline
can be harmful.
Frequent and prolonged contact with
engine oil may cause skin cancer.
Take protective measures
and wear
protective clothing
and equipment.
Wash all exposed skin with soap and
water.
Maintenance
Schedule
Failure to perform periodic
maintenance
or not following
maintenance
procedures can cause
the generator
to malfunction
and could
result in death or serious
injury.
Periodic maintenance intervals vary depending
on generator operating conditions. Operating the
generator under severe conditions, such as sustained
high-load, high-temperature, or unusually wet or
dusty environments, will require more frequent
periodic maintenance. The intervals listed in the
maintenance schedule should be treated only as a
general guideline.
Following the maintenance schedule is important
to keep the generator in good operating condition.
The following is a summary of maintenance items by
periodic maintenance intervals.
Engine Oil
Check Level
Change
Change
-
-
Cooling
Check/Clean
....
Features
Air Filter
Check
-
Clean 1
-
Replace
Spark Plug
-
-
-
Check/Clean
Replace
Spark Arrestor
-
-
-
Check/Clean
-
Service more frequently if operating in dry and dusty conditions.
28
WESTPR0
POWER
SYSTEMS

Advertisement

Chapters

Table of Contents
loading

Table of Contents