Weather will affect engine oil performance. Change the type of engine oil used based on weather conditions to suit the engine needs. HAVE QUESTIONS? Email us at service@wpowereq.com or call 1-855-944-3571 2 | Westinghouse Outdoor Power Equipment...
IMPORTANT: KEEP YOUR PURCHASE RECEIPT TO ENSURE TROUBLE-FREE WARRANTY COVERAGE. PRODUCT REGISTRATION To ensure trouble-free warranty coverage, it is important you register your Westinghouse generator. You can register your generator by either: 1. Filling in the product registration form below and mailing to:...
NOTE: Indicates a procedure, practice or condition that should be followed in order for the generator to function in the manner intended. Read Manufacturer’s Instructions Read Safety Messages Before Proceeding Wear Personal Protective Equipment (PPE) Westinghouse Outdoor Power Equipment | 5...
Never use the generator to power medical support engine misfires often. equipment. Always disconnect tools or Always remove any tools or other service equipment used appliances from the generator during maintenance from the generator before operating. before starting. 6 | Westinghouse Outdoor Power Equipment...
MWE Investments LLC Columbus Ohio 43228 USA MWE Investments LLC Designed in Columbus , Ohio USA Columbus Ohio 43228 Etats-Unis Co n u à columbus , Ohio,tats-Unis Made in China/ Fabriqu é en Chine Westinghouse Outdoor Power Equipment | 7...
Page 8
SAFETY SAFETY LABELS AND DECALS 8 | Westinghouse Outdoor Power Equipment...
• Make sure the generator and propane tank are on a flat surface before operating. • If there is a propane odor do not start the unit because there may be a potential leak. • Never place propane tank near engine exhaust. Westinghouse Outdoor Power Equipment | 9...
WHEEL KIT ACCESSORIES BOX Open the Wheel Kit Accessories box and verify the contents against the list right. If any parts are missing, please locate an authorized Westinghouse Generator dealer at service@wpowereq.com or call 1-855-944-3571. LPG hose is shipped under...
(+) battery post. Make sure flange bolts (2). boot is over battery post. 2. Clip the battery quick connects ends together to connect battery. Figure 3 -Connect Battery Figure 1 - Assemble Mounting Feet to Frame Westinghouse Outdoor Power Equipment | 11...
Control Panel: Contains the circuit breakers Single Piece Handle: Includes rubber grip. Allows and outlets. you to easily push or pull unit with one hand. Oil Fill Plug/Dipstick: Must be removed to add and check oil. 12 | Westinghouse Outdoor Power Equipment...
Page 13
Spark Plug Boot (Wire): Must be removed when servicing the engine or the spark plug. Muffler and Spark Arrester: Avoid contact until engine is cooled down. Spark arrestor prevents sparks from exiting the muffler. It must be removed for servicing. Westinghouse Outdoor Power Equipment | 13...
The frequency and voltage can vary +/- 5% and 120V or 240V output. still be within tolerance. Voltage Ground Terminal: The ground terminal is used to ground the generator. Frequency in hertz Lifetime run hours Maintenance Reminders 14 | Westinghouse Outdoor Power Equipment...
• Block cooling vents consumption and spark plug fouling. Contact our service • Block air intake system team 1-855-944-3571 for altitude part kits. High Altitude Carburetor Kit Part Number: 140571 High Altitude DF Regulator Part Number: 140565 Westinghouse Outdoor Power Equipment | 15...
Using Extension Cords Westinghouse Outdoor Power Equipment assumes no responsibility for the content within this table. The use of this table is the responsibility of the user only. This table is intended for reference only. The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are highly variable.
Filling the fuel tank with gasoline while the TRANSFER SWITCH CONNECTIONS generator is running can cause gasoline to leak The Westinghouse generator is wired with the neutral and come in contact with hot surfaces that can ignite the gasoline. bonded to ground. If you are connecting your generator...
Do not use provided LPG hose for any other appliances. Always turn off the propane tank and disconnect LPG hose when not in Avoid prolonged breathing of gasoline vapors. use. 18 | Westinghouse Outdoor Power Equipment...
Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only operate the generator outside and away from windows, doors and vents. Westinghouse Outdoor Power Equipment | 19...
3. The total running power demand of all the devices that will be connected to any one of the generator’s outlets must not exceed the generator’s specified running power output or 3,700 W, whichever is the lesser. 20 | Westinghouse Outdoor Power Equipment...
OFF position (see Figure 13 below). 9. Move the choke lever to the ON position (see Figure 10 below). Figure 13 - Choke Lever - OFF Figure 10 - Choke Lever - ON Westinghouse Outdoor Power Equipment | 21...
START STOP Figure 15 - Choke - OFF 9. Make sure LPG hose is safely secured from generator to tank and tank valve is open (see Figure 16). Figure 16 - Connect Propane Tank 22 | Westinghouse Outdoor Power Equipment...
Always perform maintenance in a well- Allow hot components to cool to ventilated area. Gasoline fuel and fuel the touch prior to performing any vapors are extremely flammable and maintenance procedure. can ignite under certain conditions. Westinghouse Outdoor Power Equipment | 23...
Spark Plug Check/Clean Replace Spark Arrestor Check/Clean *Service more frequently if operating in dry and dusty conditions TABLE 2: MAINTENANCE SCHEDULE - AUTHORIZED WESTINGHOUSE SERVICE DEALER PERFORMED After First 20 After 50 Hours After 100 Hour After 300 Hours Before Every...
5. If the spark arrestor screen shows signs of wear (rips, tears or large openings in the screen), replace the WARNING spark arrestor screen. NOTE: Only use Westinghouse spark arrestors as replacements. Hot Surfaces. When operating machine, do not touch hot surfaces. Keep machine away from 6.
8. Continue to add oil until the oil is at the correct level 5. Remove oil fill plug/dipstick (see Figure 22 below). (see Figure 23). Figure 22 - Oil Fill Plug/Dipstick 26 | Westinghouse Outdoor Power Equipment...
NEVER twist or tear the foam air filter element during cleaning or drying. Only apply slow but firm squeezing action. 6. Rinse in clean water by submerging the air filter elements in fresh water and applying a slow squeezing action Westinghouse Outdoor Power Equipment | 27...
Never apply any side load or move the spark plug laterally when Westinghouse Part Number: 180526 removing the spark plug. Applying a side load or moving the spark plug laterally may crack and damage the spark plug boot. 28 | Westinghouse Outdoor Power Equipment...
(0.09 ± 0.11 mm) (0.11 ± 0.13 mm) Dimensions 5 5/16in by 3in by 5 3/8in Bolt Torque 8-12N.m 8-12N.m 6. If an adjustment is required, hold the adjusting nut and loosen the jam nut. Westinghouse Outdoor Power Equipment | 29...
1. Make sure the Engine Switch is switched to STOP. Maintenance). 2. Disconnect the battery. 10. Move the generator to a clean, dry place for storage. 3. Clean the generator as outlined in Cleaning the Generator. 30 | Westinghouse Outdoor Power Equipment...
4. If trying 1-3 above does not solve 4. Take the generator to your nearest authorized service steady RPM. the problem, the cause might be a dealer. fault in the generator Westinghouse Outdoor Power Equipment | 31...
Need help?
Do you have a question about the WH10000DF and is the answer not in the manual?