Model Number | Running Watts | Peak Watts | Fuel Tank Size (G/L) | Rated Speed (RPM) | Ignition Type | Spark plug | Engine Disp (cc) | Stroke X Bore | Oil Capacity (L) | Oil Type |
WH10000DF | 8000 Gas 7200 LPG | 10000 Gas 9000 LPG | 6.6G/25L | 3600 | TCI | F7TC | 420 | 66X90 | 1.10 | 10W30 |
NOTICE
Even with a carburetor modification, engine horsepower will decrease about 3.5% for each 300 meter (1,000 foot) increase in altitude. The effect of altitude on horsepower will be greater if no carburetor modification is made. A decrease in engine horsepower will decrease the power output of the generator. Weather will affect engine oil performance. Change the type of engine oil used based on weather conditions to suit the engine needs.
KEEP YOUR PURCHASE RECEIPT TO ENSURE TROUBLE-FREE WARRANTY COVERAGE.
To ensure trouble-free warranty coverage, it is important you register your Westinghouse generator.
You can register your generator by either:
The words DANGER, WARNING, CAUTION and NOTICE are used throughout this manual to highlight important information. Be certain that the meanings of these alerts are known to all who work on or near the equipment.
This safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Please read and abide by the message that follows the safety alerts symbol.
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which can cause damage to the generator, personal property and/or the environment, or cause the equipment to operate improperly.
NOTE: Indicates a procedure, practice or condition that should be followed in order for the generator to function in the manner intended.
Symbol | Description |
Safety Alert Symbol | |
Asphyxiation Hazard | |
Burn Hazard | |
Burst/Pressure Hazard | |
Don't leave tools in the area | |
Electrical Shock Hazard | |
Explosion Hazard | |
Fire Hazard | |
Lifting Hazard | |
Pinch-Point Hazard | |
Read Manufacturer's Instructions | |
Read Safety Messages Before Proceeding | |
Wear Personal Protective Equipment (PPE) |
Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.
Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only operate the generator outside and away from windows, doors and vents.
Voltage produced by the generator could result in death or serious injury.
Gasoline and gasoline vapors are extremely flammable and explosive under certain conditions.
Never operate the generator if powered items overheat, electrical output drops, there is sparking, flames or smoke coming from the generator, or if the receptacles are damaged.
Never use the generator to power medical support equipment.
Always remove any tools or other service equipment used during maintenance from the generator before operating.
NOTICE
Never modify the generator.
Never operate the generator if it vibrates at high levels, if engine speed changes greatly or if the engine misfires often.
Always disconnect tools or appliances from the generator before starting.
Gasoline and liquid petroleum gas (LPG) are highly explosive and flammable. Explosions and fire can cause severe burns or death.
Gasoline and gasoline vapor (Gas)
Liquid Petroleum Gas (Propane/LPG)
Never use a gas container, LPG connector hose, LPG tank or any other fuel item that appears to be damaged.
When starting generator:
When transporting or servicing the generator:
When storing the generator:
Only use approved LPG tanks with OPD (overfilling prevention device) valve. Always keep the tank in a vertical position with the valve on top and installed at ground level on a flat surface. Do not allow tanks to be around any heat source and make sure it is not exposed to the sun, rain and dust. When transporting and storing, turn off the tank valve and fuel valve, and disconnect the tank. Make sure to always cover the generator and tank outlet with protective plastic caps.
Do not allow children to tamper or play with the propane tank or hose connections.
If there is a strong smell of propane while operating the generator close the valve on the propane tank immediately. Once the propane is off, use soapy water to check for leaks on the hose and connections on the tank valve and the generator. Do not smoke or light a cigarette or check for leaks using any open flame source such as a match or lighter. If a leak is found contact a qualified technician to inspect and repair the LPG system before using the generator.
Always have assistance when lifting the generator. The generator is heavy; lifting it could cause bodily harm.
Avoid cutting on or near staples to prevent personal injury.
Tools required – box cutter or similar device.
Manual
Quick Start Guide/Maintenance Schedule
1.1 Liter Bottle of SAE 10W30 Oil (1)
LPG Hose (1)
Spark Plug Socket Wrench (1)
Wheel Kit Accessories Box
Funnel (1)
WHEEL KIT ACCESSORIES BOX
Open the Wheel Kit Accessories box and verify the contents against the list right. If any parts are missing, please locate an authorized Westinghouse Generator dealer at service@wpowereq.com or call 1-855-944-3571.
BEFORE ASSEMBLING THE GENERATOR, REVIEW THE SAFETY SECTION STARTING.
Never lift the generator without assistance. The generator is heavy and lifting without assistance could result in personal injury.
Never use the handles as a lifting point to support the entire weight of the generator. Only use the handles to move the generator by lifting the handles and using the wheels to move the generator.
Use caution when collapsing the handles. Hands and fingers could get caught and pinched.
NOTICE
Assembling the generator will require lifting the unit on one side. Make sure all engine oil and fuel are drained from the unit prior to assembling. Once assembled, the wheel kit is not intended for onroad use. The wheel kit is designed for use on this generator only.
To avoid electric shock:
BEFORE STARTING THE GENERATOR, REVIEW SAFETY SECTION STARTING.
Location Selection – Before starting the generator, avoid exhaust and location hazards by verifying:
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide.
This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents.
Avoid other generator hazards.
READ MANUAL BEFORE USE.
Always operate the generator on a level surface. Placing the generator on non level surfaces can cause the generator to tip over, causing fuel and oil to spill. Spilled fuel can ignite if it comes in contact with an ignition source such as a very hot surface.
NOTICE
Only operate the generator on a solid, level surface. Operating the generator on a surface with loose material such as sand or grass clippings can cause debris to be ingested by the generator that could:
Weather – Never operate your generator outdoors during rain, snow or any combination of weather conditions that could lead to moisture collecting on, in or around the generator.
Dry Surface – Always operate the generator on a dry surface free of any moisture.
No Connected Loads – Make sure the generator has no connected loads before starting it. To ensure there are no connected loads, unplug any electrical extension cords that are plugged into the control panel receptacles.
NOTICE
Starting the generator with loads already applied to it could result in damage to any appliance being powered off the generator during the brief start-up period.
Grounding the Generator – The National Electric Code (NEC), as well as many local electrical codes, may require the generator to be connected to earth ground. The most common application that requires a ground rod is when you are using the generator as a separately derived system to provide back up power to your house. Typically this is when a transfer switch has a switched neutral.
As the generator application has many variables that cannot be determined by the manufacturer of the generator, a licensed electrician will need to determine if a grounding rod is needed.
If a licensed electrician has determine the application requires a ground rod, make sure it is connected to earth ground by connecting the ground terminal on the control panel to earth ground using copper wire (minimum 10 AWG). Consult a qualified electrician for local grounding requirements.
Neutral Bonded: There is a permanent conduct or between the generator (stator winding) and the frame.
Be sure the generator is properly connected to earth ground before operating. The generator must be grounded to prevent electrical shock due to faulty appliances.
High Altitude Operation
Engine power is reduced the higher you operate above sea level. Output will be reduced approximately 3.5% for every 1000ft of increased altitude from sea level. This is a natural occurrence and cannot be adjusted by engine. Increased exhaust emissions can also result due to increased fuel mixture. Other issues include hard starting, increased fuel consumption and spark plug fouling. Contact our service team 1-855-944-3571 for altitude part kits.
High Altitude Carburetor Kit Part Number: 140571
High Altitude DF Regulator Part Number: 140565
Using Extension Cords
Westinghouse Outdoor Power Equipment assumes no responsibility for the content within this table. The use of this table is the responsibility of the user only. This table is intended for reference only. The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are highly variable. Always check with local regulations and a licensed electrician prior to installing or connecting an electrical appliance.
Using Westinghouse Power Cord
Use the extension cord chart to determine the size of the conductor for extension cord applications. Determine the distance of the generator to the appliance on the top line of the chart. Then select the rated amperage of the generator on the left side of the chart. Where the two meet is the size of the conductor required for the application.
The Westinghouse power cord (shown right) is connected to the generator at the L14-30R 120/240 plug. The opposite end of the power cord is a fan tail receptacle with 2 green receptacles and 2 red receptacles. Each receptacle is rated at 120 volts AC. To balance the load on the generator's alternator, use the red and green identifiers on the fan tail receptacle. To keep the load balanced, connect the loads so that both color receptacles are used. An example is one in red and one in green. Do not connect 2 in red and none in green, or 2 in green and none in red. If only one color receptacle is used with multiple loads, the alternator may experience an unbalanced load, causing undue vibration to generator.
It is recommended to use a manual transfer switch when connecting directly to a buildings electrical system. Connecting a portable generator to a buildings electrical system must be made in strict compliance with all national and local electrical codes and laws, and be completed by a qualified electrician.
The Westinghouse generator is wired with the neutral bonded to ground. If you are connecting your generator to a panel board transfer switch, a licensed electrician will need to consider removing the bonded neutral to ensure proper operation of household GFCI circuits. Begin by removing the alternator cover. Once the cover is off remove the nut that holds the bonded ground jumper wire (see "2" in Figure 5). Once the nut is removed take the bonded jumper wire off and re-secure the nut. Next remove the screw holding the neutral ground wire (see "1" in Figure 5). Attach the bonded jumper wire (2) to the neutral ground (1) and tighten the screw.
If the bonded neutral is removed the generator must be relabeled as floating neutral on the control panel.
If your generator is equipped with GFCI receptacles, removing the bonded neutral may not allow proper operation of the GFCI receptacles. Always keep the jumper wire in case it is needed for future use when not connected to a transfer switch.
BEFORE ADDING/CHECKING ENGINE FLUIDS AND FUEL, REVIEW SAFETY SECTION STARTING.
Filling the fuel tank with gasoline while the generator is running can cause gasoline to leak and come in contact with hot surfaces that can ignite the gasoline.
Before starting the generator, always check the level of:
Once the generator is started and the engine gets warm, it is not safe to add gasoline to the fuel tank or engine oil to the engine while the engine is running or the engine and muffler are hot.
Internal pressure can build in the engine crankcase while the engine is running. Removing the oil fill plug/ dipstick while the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin. Allow engine oil to cool for several minutes before removing the oil fill plug/dipstick.
The unit as shipped does not contain oil in the engine. You must add engine oil before starting the generator for the first time. See Checking Engine Oil and Adding Engine Oil for instructions on checking engine oil level and the procedure for adding engine oil.
NOTICE
The engine does not contain engine oil as shipped. Attempting to start the engine can damage engine components. The owner of the generator is responsible to ensure the proper oil level is maintained during the operation of the generator. Failure to maintain the proper oil level can result in engine damage.
NOTICE
During the first five hours of operating the generator make sure to not exceed 50% of the rated running watts until the unit is broken in properly. Make sure to vary to load occasionally to allow stator windings to heat and cool. Adjusting the load will also help seat piston rings. Check oil more often during the first couple times of operating the generator.
NOTICE
Weather will affect engine oil performance. Change the type of engine oil used based on weather conditions to suit the engine needs.
BEFORE ADDING GAS TO THE TANK PLEASE REVIEW FUEL SAFETY SECTION
Never refuel the generator while the engine is running.
Always turn the engine off and allow the generator to cool before refueling.
Required Gasoline – Only use gasoline that meets the following requirements:
Filling the Fuel Tank – Follow the steps below to fill the fuel tank:
Avoid prolonged breathing of gasoline vapors.
CONNECTING TO STANDARD LPG/PROPANE TANK
BEFORE CONNECTING PROPANE TANK TO THE GENERATOR PLEASE REVIEW FUEL SAFETY SECTION
Connecting LPG Tank
NOTICE
Do not start generator if you smell propane. This may result in explosion hazard. Do not use provided LPG hose for any other appliances. Always turn off the propane tank and disconnect LPG hose when not in use.
BEFORE CONNECTING PROPANE TANK TO THE GENERATOR PLEASE REVIEW FUEL SAFETY SECTION
You can hook up you Duel Fuel Generator to a large home LP tank. It is required that you consult a plumber to properly connect your generator to the tank.
To properly connect with a large propane tank you must first check and confirm the LP fuel pressure at the outlet of the LP tank. The LP fuel pressure should be 14-10" of water column, which is the standard fuel pressure for residential gas fired appliances.
If the LP fuel pressure is within the 14-10" water column range, the primary fuel regulator should be removed from the fuel line components. Then plumb directly from the LP tank to the secondary regulator assembled to the generator.
You must consult a certified plumber to connect to large LP tank safely.
BEFORE STARTING THE GENERATOR, REVIEW SAFETY SECTION STARTING.
Before attempting to start the generator, verify the following:
Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.
Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only operate the generator outside and away from windows, doors and vents.
NOTICE
The engine is equipped with a low oil shutdown switch. If the oil level becomes low, the engine may shut down and not start until the oil is filled to the proper level. Poor oil quality may interfere with the operation of the low oil shutdown switch.
The owner of the generator is responsible to ensure the proper oil level is maintained during the operation of the generator. Failure to maintain the proper oil level can result in engine damage.
NOTICE
When operating on LPG it is common for frost to form on the tank and regulators. This is not an indication of a problem. The amount of frost that forms can be affected by the size of the container, the amount of fuel being used, the humidity of the air and other operating conditions. In standard use this frost may reduce flow of gas and lower performance. If frost becomes an issue try exchanging fuel tanks to allow the first tank to warm up. You can also temporarily warm the tank up by pouring warm water over the top of the propane tank.
If you are switching fuel sources make sure to shut the generator down first and follow instructions on starting with your desired fuel source.
NOTICE
If you do not plan on operating the unit on propane do not leave the propane tank valve open. When starting on propane the engine may run rough for a few seconds while it purges gasoline in the carburetor.
120-Volt AC devices have two different electric power demands that must be taken into consideration, namely the running power and the starting/peak power. Both are measured in Watts (typically abbreviated as "W").
The steady state continuous load is the running power demand and this is often marked on the device near its model number or serial number. Sometimes the device might only be marked with its voltage (i.e. 120 V) and current draw (e.g. 6 Amp or 6 A), in which case the running power demand in Watts can be obtained by multiplying the voltage times the current, e.g. 120 V × 20 A = 2,400 W.
Simple resistive 120-Volt AC devices such as incandescent bulbs, toasters, heaters, etc. have no extra power demand when starting, and so their starting power demands are the same as their running power demands.
More complex 120-Volt AC devices containing inductive or capacitive elements such as electric motors have a momentary extra power demand when starting, which can be up to seven times the running power demand or more. Manufacturers of such devices rarely publish this starting power demand and so it's often necessary to estimate it. A rule of thumb for devices fitted with an electric motor is to apply a starting power multiplier of 1.2 for small hand-held or portable devices and a value of 3.5 for larger stationary devices. For example, a 900 W angle grinder can be assumed to have a starting power demand of at least 1.2 × 900 W, which equals 1,080 W. Similarly, a 1,650 W air compressor can be assumed to have a starting power demand of at least 3.5 × 1,650 W, which equals 5,775 W.
To prevent overloading of the generator's 120-Volt AC system:
Normal Operation
During normal operation, use the following steps to stop START your generator:
During an Emergency
If there is an emergency and the generator must be stopped quickly, position the engine control switch to the STOP position immediately.
BEFORE PERFORMING MAINTENANCE ON THE GENERATOR, REVIEW THE SAFETY SECTION STARTING ON PAGE 5, AS WELL AS THE FOLLOWING SAFETY MESSAGES.
Avoid accidentally starting the generator during maintenance by removing the spark plug boot from the spark plug. For electric start generators, also disconnect the battery cables from the battery (disconnect the black negative (-) cable first) and place the cables away from the battery posts to avoid arcing.
Allow hot components to cool to the touch prior to performing any maintenance procedure.
Internal pressure can build in the engine crankcase while the engine is running. Removing the oil fill plug/ dipstick while the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin. Allow engine oil to cool for several minutes before removing the oil fill plug/dipstick.
Always perform maintenance in a wellventilated area. Gasoline fuel and fuel vapors are extremely flammable and can ignite under certain conditions.
Failure to perform periodic maintenance or not following maintenance procedures can cause the generator to malfunction and could result in death or serious injury.
NOTICE
Periodic maintenance intervals vary depending on generator operating conditions. Operating the generator under severe conditions, such as sustained high-load, high-temperature, or unusually wet or dusty environments, will require more frequent periodic maintenance. The intervals listed in the maintenance schedule should be treated only as a general guideline.
Avoid skin contact with engine oil or gasoline. Prolonged skin contact with engine oil or gasoline can be harmful. Frequent and prolonged contact with engine oil may cause skin cancer. Take protective measures and wear protective clothing and equipment. Wash all exposed skin with soap and water.
Following the maintenance schedule is important to keep the generator in good operating condition. The following is a summary of maintenance items by periodic maintenance intervals.
TABLE 1: MAINTENANCE SCHEDULE - OWNER PERFORMED
Maintenance Item | Before Every Use | After First 20 Hours or First Month of Use | After 50 Hours of Use or Every 6 Months | After 100 Hour of Use or Every 6 Months | After 300 Hours of Use or Every Year |
Engine Oil | Check Level | Change | Change | - | - |
Cooling Features | Check/Clean | - | - | - | - |
Air Filter | Check | - | Clean* | - | Replace |
Spark Plug | - | - | - | Check/Clean | Replace |
Spark Arrestor | - | - | - | Check/Clean | - |
*Service more frequently if operating in dry and dusty conditions
TABLE 2: MAINTENANCE SCHEDULE - AUTHORIZED WESTINGHOUSE SERVICE DEALER PERFORMED
Maintenance Item | Before Every Use | After First 20 Hours or First Month of Use | After 50 Hours of Use or Every 6 Months | After 100 Hour of Use or Every 6 Months | After 300 Hours of Use or Every Year |
Valve Clearance | - | - | - | - | Check/Adjust |
Fuel Filter | - | - | - | Check/Clean | - |
The VFT meter on this unit has programmed maintenance reminders. When the VFT meter shows:
This is to remind you to change the oil after the initial 25 hours of run time.
It is time to clean the air filter.
It is time change/clean the fuel filter, clean the air filter, and change the oil.
Hot Surfaces. When operating machine, do not touch hot surfaces. Keep machine away from combustibles during use. Hot surfaces could result in severe burns or fire.
Check and clean the spark arrestor after every 100 hours of use or 6 months.
Engine Oil Specification
NOTICE
Always maintain proper engine oil level. Failure to maintain proper engine oil level could result in severe damage to the engine and/or shorten the life of the engine. Always use the specified engine oil. Failure to use the specified engine oil can cause accelerated wear and/or shorten the life of the engine.
Engine oil level should be checked before every use.
NOTICE
Never dispose of used engine oil by dumping the oil into a sewer, on the ground, or into ground water or waterways. Always be environmentally responsible. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility.
Never use gasoline or other flammable solvents to clean the air filter. Use only household detergent soap to clean the air filter.
Cleaning the Air Filter
The air filter must be cleaned after every 50 hours of use or 3 months (frequency should be increased if generator is operated in a dusty environment).
The spark plug must be checked and cleaned after every 100 hours of use or 6 months and must be replaced after 300 hours of use or every year.
NOTICE
Use only recommended spark plugs when servicing. The manufacturer is not responsible for engine damage when using spark plugs not recommended by the manufacturer.
Recommended Spark Plug Replacement:
NGK: (1034) BP7ES (Replacement)
Torch: F7TC (OE Spark Plug)
Westinghouse Part Number: 180526
Checking and adjusting valve lash must be done when the engine is cold.
(Table 1) Standard Valve Lash
Intake Valve | Exhaust Valve | |
Valve Lash | 0.0035 ± 0.0043 in (0.09 ± 0.11 mm) | 0.0043 ± 0.0051 in (0.11 ± 0.13 mm) |
Bolt Torque | 8-12N.m | 8-12N.m |
BATTERY REPLACEMENT
See below for the battery specification when replacing the battery.
Westinghouse Part No. | 100557 |
After Market Battery Model | YT9A |
Volts | 12 |
Amp Hr | 9 |
Dimensions | 5 5/16in by 3in by 5 3/8in |
It is important to inspect and clean the generator before every use.
Clean All Engine Air Inlet and Outlet Ports – Make sure all engine air inlet and outlet ports are clean of any dirt and debris to ensure the engine does not run hot.
Clean All Engine Cooling Fins – Use a damp rag and a brush to loosen and remove all dirt on or around the engine's cooling fins.
Clean All Alternator Cooling Air Inlets and Exhaust Ports – Make sure the cooling air inlets and exhaust ports of the alternator are free of any debris and obstructions. Use a vacuum cleaner to remove dirt and debris stuck in the cooling air inlets and exhaust ports.
General Cleaning of the Generator – Use a damp rag to clean all remaining surfaces.
Never store a generator with fuel in the tank indoors or in a poorly ventilated area where the fumes can come in contact with an ignition source such as a: 1) pilot light of a stove, water heater, clothes dryer or any other gas appliance; or 2) spark from an electric appliance.
NOTICE
Gasoline stored for as little as 60 days can go bad, causing gum, varnish and corrosive buildup in fuel lines, fuel passages and the engine. This corrosive buildup restricts the flow of fuel, preventing an engine from starting after a prolonged storage period.
Proper care should be taken to prepare the generator for any storage.
Before attempting to service or troubleshoot the generator, the owner or service technician must first read the owner's manual and understand and follow all safety instructions. Failure to follow all instructions may result in conditions that can lead to voiding of the EPA certification or product warranty, serious personal injury, property damage or even death.
PROBLEM | POTENTIAL CAUSE | SOLUTION |
Engine is running, but no electrical output |
|
|
Engine will not start or remain running while trying to start. |
|
|
Generator suddenly stops running. |
|
|
Engine runs erratic; does not hold a steady RPM. |
|
|
WH10000DF EXPLODED VIEW PART NO.
NO. | PART. | DESCRIPTION |
1 | NA | FRAME |
2 | NA | ISOLATOR |
3 | NA | METAL CAP |
4 | 100520 | NUT M8 |
5 | 180524 | NUT M8 |
6 | 140508 | CLIP, FUEL LINE Φ7.5 |
7 | 180563 | BRACKET,AIR CLEANER |
8 | 120505 | BOLT M6X12 |
9 | 110504 | MUFFLER BRACKET |
10 | 300837 | ENGINE ASSY |
11 | 300836 | PANEL COMP |
11.1 | 130542 | ON/OFF/RUN SWITCH |
11.2 | 130158 | VFT METER |
11.3 | 300674 | GROUND TERMINAL ASSEMBLY |
11.4 | 130512 | DOUBLE SOCKET. 5-20R/UL |
11.5 | 130564 | THERMAL PROTECTOR 20A |
11.6 | 300838 | THERMAL PROTECTOR 33A |
11.7 | 130505 | L14-30 RECEPTACLE |
12 | 180562 | DUSTPROOF SHEET |
13 | 100516 | BOLT M8X16 |
14 | 120501 | ALTERNATOR ASSY |
14.1 | 130533 | CARBON BRUSH ASSEMBLY |
14.2 | 120503 | GROUNDING POST COMP. |
15 | 120504 | MOTOR STAND |
16 | 100540 | GASKET, ROTOR BOLT Φ10.5×Φ30×4 |
17 | 120514 | BOLT M10X1.25X283 |
18 | 120513 | BOLT M6X200 |
19 | 300115 | CLIP, FUEL LINE Φ9.5 |
20 | 15053 | FILTER,FUEL |
21 | 120537 | BOLT M5X12 |
22 | 120517A | AUTOMATIC VOLTAGE REGULA- TOR |
23 | 120519 | END COVER,GENERATOR |
24 | 110501 | GASKET, EXHAUST PIPE |
25 | 110502 | SPRING WASHER Ф8 |
26 | 110500 | MUFFLER COMP |
27 | 150500 | FUEL TANK ASSEMBLY |
27.1 | 150529 | FUEL STRAINER |
27.2 | 230514 | FUEL GAUGE |
28 | 120541 | BOLT M6X25 |
29 | 150501 | WASHER FUEL TANK |
30 | 150512 | CARBON TANK COMP |
31 | 120542 | FRAME WIRE |
32 | NA | TOOTH TYPE GASKET Ф8 |
33 | 150505 | FUEL TANK CAP COMP |
34 | 150552 | FUEL COCK |
35 | 100547 | WASHER |
36 | 160513 | THE CARBON TANK IS CON- NECTED WITH THE AIR FILTER |
37 | 100548 | NUT M6 |
38 | 100594 | VALVE |
39 | 100512 | FOOT BRACKET |
40 | 100515 | VIBRATION ISOLATION PAD, SQUARE |
41 | 100582 | BOLT M6X28 |
42 | 100510 | FLAT WASHER Φ13XΦ37X4 |
43 | 100506 | WHEEL |
44 | 190311 | AXLE |
45 | 100508 | COTTER PIN |
46 | 100527 | PLUG, HANDLE |
47 | 100525 | BOLT, HANDLE M10XΦ12.5X53.5 |
48 | 100521 | HANDLE ASSEMBLY |
49 | 100523 | RUBBER, HANDLE |
50 | 120509 | BOLT M5X230 |
51 | 120510 | NUT M5 |
52 | 120511 | FLAT WASHER Ф5 |
53 | 120512 | SPRING WASHER Ф5 |
54 | 180561 | GUARD COVER, CRANKCASE |
55 | 110503 | BOLT M8X30 |
56 | 120518 | BOLT M5X16 |
57 | NA | CLIP, FUEL LINE Ф8 |
58 | 100558 | BATTERY HOLDER |
59 | NA | NUT M5 |
60 | 120516 | GROUNDING WIRE |
61 | 300839 | BATTERY CABLE KIT |
62 | 100595 | COVER, LPG REGULATOR |
63 | 100557 | BATTERY |
64 | 130535 | HEXAGON PATTERN PAN HEAD SCREWS |
65 | 100551 | NUT M10 |
66 | 130536 | BOLT M6X16 |
67 | NA | LOCK NUT M6 |
68 | 130538 | FUEL SELECTOR SWITCH |
69 | 100586 | LOW PRESSURE PIPE FROM SWITCH |
70 | 100587 | LOW PRESSURE PIPE SHORT |
71 | NA | CLIP Φ12 |
72 | 100589 | FUEL HOSE FROM FUEL COCK |
73 | 100590 | FUEL HOSE |
74 | 100596 | RELIEF VALVE ASSEMBLY |
NA | 230523 | 1.1L OIL BOTTLE |
NA | 10003 | WH10000DF Owners Manual |
Westinghouse Generator Accessories (call to order)
210004 | GENERATOR COVER |
3013425C | 25' GENERATOR CORD: 30A 120V TT-30P TO TT-30R |
3013450C | 50' GENERATOR CORD: 30A 120V TT-30P TO TT-30R |
3015425C | 25' GENERATOR CORD: 30A 120V L5-30P TO TT-30R |
30151425C | 25' GENERATOR CORD: 30A 120V L5-30P TO (3X) 5-20R |
3021225C | 25' GENERATOR CORD: 30A 120V L14-30P TO L14-30R |
3021250C | 50' GENERATOR CORD: 30A 120V L14-30P TO L14-30R |
5027825C | 25' GENERATOR CORD: 50A 120/240V 14-50P TO 14-50R |
5027850C | 50' GENERATOR CORD: 50A 120/240V 14-50P TO 14-50R |
30211625C | 25' GENERATOR CORD: 30A 120V L14-30P TO (4X) 5-20R |
30211650C | 50' GENERATOR CORD: 30A 120V L14-30P TO (4X) 5-20R |
30114A | GENERATOR PLUG ADAPTER: 30A 120V L14-30P TO TT-30R |
50218A | GENERATOR PLUG ADAPTER: 50A 120/240V L14-30P TO 14-50RR |
302116A | GENERATOR PLUG ADAPTER: 30A 120V L14-30P TO (4X) 5-20R |
30154A | GENERATOR PLUG ADAPTER: 30A 120V L5-30P TO TT-30R |
30136A | GENERATOR PLUG ADAPTER: 30A 120V TT-30P TO L5-30R |
301514A | GENERATOR PLUG ADAPTER: 30A 120V L5-30P TO (3X) 5-20R |
30194A | GENERATOR PLUG ADAPTER: 30A 120V 5-20P TO TT-30R |
30196A | GENERATOR PLUG ADAPTER: 30A 120V 5-20P TO L5-30R |
50158A | GENERATOR PLUG ADAPTER: 30A 120V L5-30P TO 14-50R |
50138A | GENERATOR PLUG ADAPTER: 30A 120V TT-30P TO 14-50R |
WH10000DF ENGINE PART NO.
NO. | PART. | DESCRIPTION |
1 | 190223 | THE CRANKSHAFT BOX BODY |
2 | 180593 | BEARING |
3 | 180504 | THE CRANKSHAFT OIL SEAL |
4 | 190412 | PENDULUM STEM SEAL |
5 | 190410 | SWINGING ROD |
6 | 190409 | SWINGING ROD GASKET |
7 | 190408 | CHECK BACK CLIP |
8 | 180507 | OIL DRAIN BOLT |
9 | 180508 | OIL DRAIN BOLT WASHER |
10 | 180586 | OIL SENSOR |
11 | 130536 | BOLT WITH DISC M6X16 |
12 | 180604 | POSITIONING PIN OF CRANKCASE |
13 | 190407 | THE PISTON |
14 | 190406 | PISTON RING ASSEMBLY |
15 | 180072 | CONNECTING ROD ASSEMBLY |
16 | 190404 | THE PISTON PIN |
17 | 180791 | PISTON PIN RETAINER |
18 | 180512 | CRANKCASE COVER |
19 | 180530 | BEARING |
20 | 190225 | CENTRIFUGAL GOVERNOR GEAR ASSEMBLY |
21 | 180514 | CYLINDER HEAD |
22 | 180794 | INLET VALVE |
23 | 180795 | THE EXHAUST VALVE |
24 | 180752 | LOWER SEAT OF INLET VALVE SPRING |
25 | 180573 | VALVE SEAL |
26 | 190224 | VALVE SPRINGS |
27 | 170504 | LINE PRESSING BLOCK |
28 | 180755 | EXHAUST VALVE SPRING SEAT |
29 | NA | LIMIT PLATE ASSEMBLY |
30 | 180799 | ROCKER ARM |
31 | 180756 | HAT |
32 | 140503 | INTAKE STUD |
33 | 180571 | EXHAUST STUD |
34 | 180522 | EXHAUST GASKET |
35 | 180531 | OIL GAUGE ASSEMBLY |
36 | 110502 | SPRING WASHERS PHI 8 |
37 | 180524 | NUT M8 |
38 | 300797 | CARBURETOR ASSEMBLY |
39 | 180515 | CONTROL ARM |
40 | 180616 | WIRE HARNESS CLIP |
41 | 100548 | NUT M6 |
42 | 190403 | THE CRANKSHAFT |
43 | 190402 | THE VALVE LIFTER |
44 | 180511 | CRANKCASE GASKET |
45 | 190401 | BALANCE SHAFT |
46 | 180806 | CAMSHAFT ASSEMBLY |
47 | 180807 | COIL BOLT M8X35 |
48 | 180808 | BOLT WITH DISC M8X40 |
49 | 180742 | CYLINDER HEAD PIN |
50 | 180513 | CYLINDER HEAD GASKET |
51 | 180523 | COIL BOLT M10X80 |
52 | 180526 | THE SPARK PLUG |
53 | 180810 | THE VALVE PUSH ROD |
54 | 180811 | WIND DEFLECTOR |
55 | 120505 | BOLT WITH DISC M6X12 |
56 | 180527 | CYLINDER CRANIUM |
57 | 180528 | CYLINDER HEAD COVER GASKET |
58 | 180529 | CYLINDER HEAD COVER FASTENING BOLTS |
59 | 180519 | SPEED CONTROL CONTROLLER |
60 | 180503 | THE FLYWHEEL COMPONENTS |
61 | 180502 | THE IMPELLER |
62 | 180501 | START THE CUP |
63 | 180500 | THE FLYWHEEL NUT |
64 | 180510 | RUBBER LEAD |
65 | 180584 | IGNITER |
66 | 100518 | M6X25 FOOT SCREW FOR PADS TO LEGS |
67 | 140504 | INTAKE GASKET |
68 | 140502 | INSULATOR,CARBURETOR |
69 | 140509 | CARBURETOR GASKET |
70 | 180636 | ROCKER ARM FASTENING BOLT ASSEMBLY |
71 | 180521 | THE MUFFLER CONNECTS THE PIPE |
72 | 180516 | THE THROTTLE LEVER |
73 | 180517 | VERNIER C SPRING |
74 | 170500 | HOOD ASSEMBLY |
74.1 | 100523 | PULL HANDLE |
75 | 160500 | AIR FILTER ELEMENT |
75.1 | 160006 | AIR CLEANER ELEMENT |
76 | 180533 | EXHAUST PIPE |
77 | 180518 | SPEED REGULATING SPRING B |
78 | 140537 | EMPTY FILTER GASKET |
79 | 170502 | Q TYPE LINE CARD |
80 | 140506 | FUEL PIPE RUBBER |
81 | 170506 | CLAMPER CORD A |
82 | 180589 | BOLT WITH DISC M6X8 |
83 | 170503 | STARTING MOTOR ASSEMBLY |
84 | 180744 | VALVE LOCK CLAMP |
85 | 100589 | FUEL PIPE |
86 | 140508 | FUEL PIPE CLAMP RING Ф 7.5 |
87 | 180506 | CHARGING COIL |
88 | 100636 | BOLT M6X30 |
89 | NA | Q TYPE LINE CARD |
NA | 140571 | HIGH ALTITUDE CARBURETOR KIT 420CC (SOLD SEPARATE) |
NA | 140565 | HIGH ALTITUDE REGULATOR KIT (SOLD SEPARATE) |
NA | 140008 | FUEL SOLENOID |
NA | 170040 | STARTING SOLENOID |
NA | 300504 | SPARK ARRESTOR |
NA | 210002 | SPARK PLUG TOOL WRENCH |
NA | 180233 | SPARK PLUG BOOT |
WestinghouseOutdoorPower.com
Service Hotline: (855) 944-3571
777 Manor Park Drive
Columbus, OH 43228