TECHNICAL SPECIFICATIONS

Model Number Running Watts Peak Watts Fuel Tank Size (G/L) Rated Speed (RPM) Ignition Type Spark plug Engine Disp (cc) Stroke X Bore Oil Capacity (L) Oil Type
WH10000DF 8000 Gas 7200 LPG 10000 Gas 9000 LPG 6.6G/25L 3600 TCI F7TC 420 66X90 1.10 10W30

NOTICE
Even with a carburetor modification, engine horsepower will decrease about 3.5% for each 300 meter (1,000 foot) increase in altitude. The effect of altitude on horsepower will be greater if no carburetor modification is made. A decrease in engine horsepower will decrease the power output of the generator. Weather will affect engine oil performance. Change the type of engine oil used based on weather conditions to suit the engine needs.

KEEP YOUR PURCHASE RECEIPT TO ENSURE TROUBLE-FREE WARRANTY COVERAGE.

PRODUCT REGISTRATION

To ensure trouble-free warranty coverage, it is important you register your Westinghouse generator.
You can register your generator by either:

  1. Filling in the product registration form below and mailing to:
    Product Registration
    Westinghouse Outdoor Power Equipment
    777 Manor Park Drive
    Columbus, Ohio 43228
  2. Registering your product Online at www.westinghouseportablepower.com/register-your-product/
    To register your generator you will need to locate the following information:

SAFETY

SAFETY DEFINITIONS

The words DANGER, WARNING, CAUTION and NOTICE are used throughout this manual to highlight important information. Be certain that the meanings of these alerts are known to all who work on or near the equipment.
warning This safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Please read and abide by the message that follows the safety alerts symbol.

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which can cause damage to the generator, personal property and/or the environment, or cause the equipment to operate improperly.

NOTE: Indicates a procedure, practice or condition that should be followed in order for the generator to function in the manner intended.

SAFETY SYMBOL DEFINITIONS

Symbol Description
warning Safety Alert Symbol
Asphyxiation Hazard
burnhazard Burn Hazard
Burst/Pressure Hazard
Don't leave tools in the area
shock hazard Electrical Shock Hazard
Explosion Hazard
Fire Hazard
Lifting Hazard
Pinch-Point Hazard
Read Manufacturer's Instructions
Read Safety Messages Before Proceeding
Wear Personal Protective Equipment (PPE)

GENERAL SAFETY RULES


Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.
Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only operate the generator outside and away from windows, doors and vents.

Voltage produced by the generator could result in death or serious injury.

  • Never operate the generator in rain or a flood plain unless proper precautions are taken to avoid being subject to rain or a flood.
  • Never use worn or damaged extension cords.
  • Always have a licensed electrician connect the generator to the utility circuit.
  • Never touch an operating generator if the generator is wet or if you have wet hands.
  • Never operate the generator in highly conductive areas such as around metal decking or steel works.
  • Always use grounded extension cords. Always use three-wire or double-insulated power tools.
  • Never touch live terminals or bare wires while the generator is operating.
  • Be sure the generator is properly grounded before operating.


Gasoline and gasoline vapors are extremely flammable and explosive under certain conditions.

  • Always refuel the generator outdoors, in a well-ventilated area.
  • Never remove the fuel cap with the engine running.
  • Never refuel the generator while the engine is running. Always turn engine off and allow the generator to cool before refueling.
  • Only fill fuel tank with gasoline.
  • Keep sparks, open flames or any other forms of ignition (such as match, cigarette, static electric source)away when refueling.
  • Never overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces. Spilled fuel can ignite. If fuel is spilled on the generator, wipe up any spills immediately. Dispose of rag properly. Allow area of spilled fuel to dry before operating the generator.
  • Wear eye protection while refueling.
  • Never use gasoline as a cleaning agent.
  • Store any containers containing gasoline in a well-ventilated area, away from any combustibles or source of ignition.
  • Check for fuel leaks after refueling. Never operate the engine if a fuel leak is discovered.


Never operate the generator if powered items overheat, electrical output drops, there is sparking, flames or smoke coming from the generator, or if the receptacles are damaged.
warning Never use the generator to power medical support equipment.
Always remove any tools or other service equipment used during maintenance from the generator before operating.
NOTICE
Never modify the generator.
Never operate the generator if it vibrates at high levels, if engine speed changes greatly or if the engine misfires often.
Always disconnect tools or appliances from the generator before starting.

SAFETY LABELS AND DECALS

FUEL SAFETY


Gasoline and liquid petroleum gas (LPG) are highly explosive and flammable. Explosions and fire can cause severe burns or death.

Gasoline and gasoline vapor (Gas)

  • Gasoline is highly flammable and explosive.
  • Gas expands and contracts with different temperatures.
  • In case of a gas fire, do not attempt to extinguish the flame if the fuel shutoff valve is in the on position. Introducing an extinguisher to a generator with an open fuel valve could create an explosion hazard.
  • Gas has a distinctive odor, this will help detect potential leaks quickly.
  • Gas vapors can cause a fire if ignited.
  • Gasoline is a skin irritant and needs to be cleaned up immediately if it comes in contact with the skin.

Liquid Petroleum Gas (Propane/LPG)

  • LPG/Propane is highly flammable and explosive.
  • Flammable gas under pressure can cause a fire or explosion if ignited.
  • LPG/Propane can settle in low places because it is heavier than air.
  • LPG/Propane has a distinctive odor added to help detect potential leaks.
  • Always keep LPG/Propane tank in an upright position.
  • When exchanging LPG/Propane tanks, be sure the tank value is the same type.
  • In case of a LPG/Propane fire, do not attempt to extinguish unless the fuel supply can be shut off.
  • LPG/Propane will burn the skin. Prevent skin contact at all times.


Never use a gas container, LPG connector hose, LPG tank or any other fuel item that appears to be damaged.

When starting generator:

  • Make sure that the gas cap, air filter, spark plug, fuel lines and exhaust system are properly in place.
  • If you spill any gasoline on the tank, allow it to fully evaporate before operating.
  • Make sure the generator and propane tank are on a flat surface before operating.
  • If there is a propane odor do not start the unit because there may be a potential leak.
  • Never place propane tank near engine exhaust.

When transporting or servicing the generator:

  • Make certain the fuel shutoff valve is off and the fuel tank is empty.
  • Make sure the LPG tank and LPG hose is not attached to the generator.
  • Disconnect the spark plug wire.

When storing the generator:

  • Store away from sparks, open flames, pilot lights, heat and other sources of ignition.
  • Do not store gas or LPG tank near furnaces, water heaters or any other appliances that produce heat or have automatic ignitions.


Only use approved LPG tanks with OPD (overfilling prevention device) valve. Always keep the tank in a vertical position with the valve on top and installed at ground level on a flat surface. Do not allow tanks to be around any heat source and make sure it is not exposed to the sun, rain and dust. When transporting and storing, turn off the tank valve and fuel valve, and disconnect the tank. Make sure to always cover the generator and tank outlet with protective plastic caps.

Do not allow children to tamper or play with the propane tank or hose connections.

If there is a strong smell of propane while operating the generator close the valve on the propane tank immediately. Once the propane is off, use soapy water to check for leaks on the hose and connections on the tank valve and the generator. Do not smoke or light a cigarette or check for leaks using any open flame source such as a match or lighter. If a leak is found contact a qualified technician to inspect and repair the LPG system before using the generator.

UNPACKING


Always have assistance when lifting the generator. The generator is heavy; lifting it could cause bodily harm.
warning Avoid cutting on or near staples to prevent personal injury.

Tools required – box cutter or similar device.

  1. Carefully cut the packing tape on top of the carton.
  2. Fold back top flaps to reveal the manual.
  3. Remove the Wheel Kit Accessories cardboard box.
  4. Carefully cut two sides of the carton to remove the generator.

WHAT COMES IN THE BOX


Manual
Quick Start Guide/Maintenance Schedule
1.1 Liter Bottle of SAE 10W30 Oil (1)
LPG Hose (1)
Spark Plug Socket Wrench (1)
Wheel Kit Accessories Box
Funnel (1)

WHEEL KIT ACCESSORIES BOX
Open the Wheel Kit Accessories box and verify the contents against the list right. If any parts are missing, please locate an authorized Westinghouse Generator dealer at service@wpowereq.com or call 1-855-944-3571.

  1. Washer (2 used)
  2. Flange Bolt M8 x16mm (4 used)
  3. Hairpin Cotter Pin (2 used)
  4. Wheel Axle Pin (2)
  5. Mounting feet (2)
  6. Wheel (2)

ASSEMBLY

INSTALLING WHEELS AND FEET


BEFORE ASSEMBLING THE GENERATOR, REVIEW THE SAFETY SECTION STARTING.

Never lift the generator without assistance. The generator is heavy and lifting without assistance could result in personal injury.
warning Never use the handles as a lifting point to support the entire weight of the generator. Only use the handles to move the generator by lifting the handles and using the wheels to move the generator.
Use caution when collapsing the handles. Hands and fingers could get caught and pinched.
NOTICE
Assembling the generator will require lifting the unit on one side. Make sure all engine oil and fuel are drained from the unit prior to assembling. Once assembled, the wheel kit is not intended for onroad use. The wheel kit is designed for use on this generator only.

INSTALLING FEET TO FRAME

  1. Place generator on a flat surface.
  2. Place a piece of cardboard or other soft material to tip the generator onto, to protect the frame paint and prevent the generator from sliding. Tip the generator onto the side.
  3. Install the mounting foot (5) to the frame using M8 flange bolts (2).
    Assembly - Step 1 - Mounting Feet to Frame

INSTALLING WHEELS TO FRAME

  1. Insert axle pin (4) through wheel (6) and place washer (1) between wheel and mounting bracket.
    Assembly - Step 2 - Wheel Assembly
  2. Place hairpin cotter pin (3) through the eye of the wheel axle pin (4) to secure wheel.
  3. Repeat previous steps on other wheel.

INSTALLING THE BATTERY


To avoid electric shock:

  • ALWAYS connect the positive (+) battery cable (red boot) first when connecting battery cables.
  • ALWAYS disconnect the negative (-) battery cable (black boot) first when disconnecting battery cables.
  • NEVER connect the negative (-) battery cable (black boot) to the positive (+) post on the battery.
  • NEVER connect the positive (+) battery cable (red boot) to the negative (-) post on the battery.
  • NEVER touch both battery posts simultaneously.
  • NEVER place a metal tool across both battery posts.
  • ALWAYS use insulated or nonconducting tools when installing the battery.
  1. Verify the positive (+) battery cable (red boot) is securely tightened to the positive (+) battery post. Make sure boot is over battery post.
  2. Clip the battery quick connects ends together to connect battery.

FEATURES

Features overview - Part 1

  1. Fuel Selector Switch: Used to select and turn on gasoline or propane fuel source.
  2. Electric Start Switch: Hold in Start position for 1 second to start engine. Make sure to turn choke on prior to cold starting.
  3. Fuel Cap: Close until clicking sound is heard.
  4. Control Panel: Contains the circuit breakers and outlets.
  5. Oil Fill Plug/Dipstick: Must be removed to add and check oil.
  6. Oil Drain Plug: Must be removed to drain engine oil
  7. Never Flat Wheels: For easy portability
  8. Fuel Shut off Valve: Controls the flow of fuel to the engine.
  9. Manual Choke: Choke must be set manually by adjusting choke lever.
  10. Single Piece Handle: Includes rubber grip. Allows you to easily push or pull unit with one hand.

Features overview - Part 2

  1. Fuel Gauge: Indicates fuel level.
  2. Spark Plug Boot (Wire): Must be removed when servicing the engine or the spark plug.
  3. Muffler and Spark Arrester: Avoid contact until engine is cooled down. Spark arrestor prevents sparks from exiting the muffler. It must be removed for servicing.

CONTROL PANEL FEATURES

Features overview - Part 3 - Control panel

  1. Fuel Selector Switch: Select and turn on gas or propane.
  2. Electric Start Switch: Hold in Start until engine starts. Make sure to manually open choke prior to starting.
  3. Data Center: The VFT Meter is 4 state LED display that will rotate through volts, frequency, and lifetime run hours. The 4th display is used for maintenance reminders and may display as 00:00. You can press the MODE button to cycle through the different displays. The meter will display volts and hertz even if there is no load connected.
    The frequency and voltage can vary +/- 5% and still be within tolerance.
  4. 120-Volt, 20-Amp Duplex GFCI Outlets (NEMA 5-20R): Each outlet is capable of carrying a maximum of 20 amps on a single receptacle or a combination of both receptacles.
  5. 20-Amp Circuit Breakers: Each circuit breaker limits the current that can be delivered through the 120-volt duplex outlets to 20amps.
  6. 25-Amp Circuit Breakers: Each push button circuit breaker controls total output per leg to L14-30 receptacle.
  7. 120/240-Volt, 30-Amp Twist Lock Outlet (NEMA L14-30R): Outlet can supply either 120V or 240V output.
  8. Ground Terminal: The ground terminal is used to ground the generator.

OPERATION

BEFORE STARTING THE GENERATOR


BEFORE STARTING THE GENERATOR, REVIEW SAFETY SECTION STARTING.
Location Selection – Before starting the generator, avoid exhaust and location hazards by verifying:

  • You have selected a location to operate the generator that is outdoors and well ventilated.
  • You have selected a location with a level and solid surface on which to place the generator.
  • You have selected a location that is at least 15 feet (4.5 m) away from any building, other equipment or combustible material.
  • If the generator is located close to a building, make sure it is not located near any windows, doors and/or vents.


Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide.
This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.

Only use OUTSIDE and far away from windows, doors, and vents.

Avoid other generator hazards.
READ MANUAL BEFORE USE.


Always operate the generator on a level surface. Placing the generator on non level surfaces can cause the generator to tip over, causing fuel and oil to spill. Spilled fuel can ignite if it comes in contact with an ignition source such as a very hot surface.
NOTICE
Only operate the generator on a solid, level surface. Operating the generator on a surface with loose material such as sand or grass clippings can cause debris to be ingested by the generator that could:

  • Block cooling vents
  • Block air intake system

Weather – Never operate your generator outdoors during rain, snow or any combination of weather conditions that could lead to moisture collecting on, in or around the generator.
Dry Surface – Always operate the generator on a dry surface free of any moisture.
No Connected Loads – Make sure the generator has no connected loads before starting it. To ensure there are no connected loads, unplug any electrical extension cords that are plugged into the control panel receptacles.
NOTICE
Starting the generator with loads already applied to it could result in damage to any appliance being powered off the generator during the brief start-up period.
Grounding the Generator – The National Electric Code (NEC), as well as many local electrical codes, may require the generator to be connected to earth ground. The most common application that requires a ground rod is when you are using the generator as a separately derived system to provide back up power to your house. Typically this is when a transfer switch has a switched neutral.
As the generator application has many variables that cannot be determined by the manufacturer of the generator, a licensed electrician will need to determine if a grounding rod is needed.
If a licensed electrician has determine the application requires a ground rod, make sure it is connected to earth ground by connecting the ground terminal on the control panel to earth ground using copper wire (minimum 10 AWG). Consult a qualified electrician for local grounding requirements.
Neutral Bonded: There is a permanent conduct or between the generator (stator winding) and the frame.

Be sure the generator is properly connected to earth ground before operating. The generator must be grounded to prevent electrical shock due to faulty appliances.

High Altitude Operation
Engine power is reduced the higher you operate above sea level. Output will be reduced approximately 3.5% for every 1000ft of increased altitude from sea level. This is a natural occurrence and cannot be adjusted by engine. Increased exhaust emissions can also result due to increased fuel mixture. Other issues include hard starting, increased fuel consumption and spark plug fouling. Contact our service team 1-855-944-3571 for altitude part kits.
High Altitude Carburetor Kit Part Number: 140571
High Altitude DF Regulator Part Number: 140565

POWERCORD

Using Extension Cords
Westinghouse Outdoor Power Equipment assumes no responsibility for the content within this table. The use of this table is the responsibility of the user only. This table is intended for reference only. The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are highly variable. Always check with local regulations and a licensed electrician prior to installing or connecting an electrical appliance.

Using Westinghouse Power Cord
Use the extension cord chart to determine the size of the conductor for extension cord applications. Determine the distance of the generator to the appliance on the top line of the chart. Then select the rated amperage of the generator on the left side of the chart. Where the two meet is the size of the conductor required for the application.
The Westinghouse power cord (shown right) is connected to the generator at the L14-30R 120/240 plug. The opposite end of the power cord is a fan tail receptacle with 2 green receptacles and 2 red receptacles. Each receptacle is rated at 120 volts AC. To balance the load on the generator's alternator, use the red and green identifiers on the fan tail receptacle. To keep the load balanced, connect the loads so that both color receptacles are used. An example is one in red and one in green. Do not connect 2 in red and none in green, or 2 in green and none in red. If only one color receptacle is used with multiple loads, the alternator may experience an unbalanced load, causing undue vibration to generator.

CONNECTING THE GENERATOR TO A BUILDING ELECTRICAL SYSTEM

It is recommended to use a manual transfer switch when connecting directly to a buildings electrical system. Connecting a portable generator to a buildings electrical system must be made in strict compliance with all national and local electrical codes and laws, and be completed by a qualified electrician.

TRANSFER SWITCH CONNECTIONS

Transfer switch connections

  1. Alternator Neutral Ground Wire (white/Green)
  2. Alternator Bonded Jumper Wire (white/Green)

The Westinghouse generator is wired with the neutral bonded to ground. If you are connecting your generator to a panel board transfer switch, a licensed electrician will need to consider removing the bonded neutral to ensure proper operation of household GFCI circuits. Begin by removing the alternator cover. Once the cover is off remove the nut that holds the bonded ground jumper wire (see "2" in Figure 5). Once the nut is removed take the bonded jumper wire off and re-secure the nut. Next remove the screw holding the neutral ground wire (see "1" in Figure 5). Attach the bonded jumper wire (2) to the neutral ground (1) and tighten the screw.
If the bonded neutral is removed the generator must be relabeled as floating neutral on the control panel.
If your generator is equipped with GFCI receptacles, removing the bonded neutral may not allow proper operation of the GFCI receptacles. Always keep the jumper wire in case it is needed for future use when not connected to a transfer switch.

ADDING / CHECKING ENGINE FLUIDS AND FUEL


BEFORE ADDING/CHECKING ENGINE FLUIDS AND FUEL, REVIEW SAFETY SECTION STARTING.

Filling the fuel tank with gasoline while the generator is running can cause gasoline to leak and come in contact with hot surfaces that can ignite the gasoline.
Before starting the generator, always check the level of:

  • Engine oil
  • Gasoline in the fuel tank

Once the generator is started and the engine gets warm, it is not safe to add gasoline to the fuel tank or engine oil to the engine while the engine is running or the engine and muffler are hot.

CHECKING AND / OR ADDING ENGINE OIL


Internal pressure can build in the engine crankcase while the engine is running. Removing the oil fill plug/ dipstick while the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin. Allow engine oil to cool for several minutes before removing the oil fill plug/dipstick.
The unit as shipped does not contain oil in the engine. You must add engine oil before starting the generator for the first time. See Checking Engine Oil and Adding Engine Oil for instructions on checking engine oil level and the procedure for adding engine oil.
NOTICE
The engine does not contain engine oil as shipped. Attempting to start the engine can damage engine components. The owner of the generator is responsible to ensure the proper oil level is maintained during the operation of the generator. Failure to maintain the proper oil level can result in engine damage.
NOTICE
During the first five hours of operating the generator make sure to not exceed 50% of the rated running watts until the unit is broken in properly. Make sure to vary to load occasionally to allow stator windings to heat and cool. Adjusting the load will also help seat piston rings. Check oil more often during the first couple times of operating the generator.
NOTICE
Weather will affect engine oil performance. Change the type of engine oil used based on weather conditions to suit the engine needs.

ADDING GASOLINE TO THE FUEL TANK


BEFORE ADDING GAS TO THE TANK PLEASE REVIEW FUEL SAFETY SECTION

Never refuel the generator while the engine is running.
burn hazard Always turn the engine off and allow the generator to cool before refueling.

Required Gasoline – Only use gasoline that meets the following requirements:

  • Unleaded gasoline only
  • Gasoline with maximum 10% ethanol added
  • Gasoline with an 87 octane rating or higher

Filling the Fuel Tank – Follow the steps below to fill the fuel tank:

  1. Shut off the generator.
  2. Allow the generator to cool down so all surface areas of the muffler and engine are cool to the touch.
  3. Move the generator to a flat surface.
  4. Clean area around the fuel cap.
  5. Remove the fuel cap by rotating counterclockwise.
  6. Slowly add gasoline into the fuel tank. Be very careful not to overfill the tank. The gasoline level should NOT be higher than the filler neck.
    Maximum Gasoline Fill Level
  7. Install the fuel cap by rotating clockwise until you hear a click, indicating the cap is completely installed.


Avoid prolonged breathing of gasoline vapors.

CONNECTING TO STANDARD LPG/PROPANE TANK


BEFORE CONNECTING PROPANE TANK TO THE GENERATOR PLEASE REVIEW FUEL SAFETY SECTION

Connecting LPG Tank

  1. Make sure the generator is off, on a flat surface in well ventilated area.
  2. Make sure propane tank valve is in the off position.
  3. Make sure the fuel selector switch on the generator control panel is pointing downward to "Propane".
  4. Remove the plastic cover on the generator propane inlet valve.
  5. Using your fingers tighten the LPG hose (included) end below to the generator propane inlet. DO NOT OVER- TIGHTEN 35-88 Ib-in maximum.
  6. Attach the other end of the hose to a tank of LPG/ Propane and hand tighten.
  7. Check all connections for leaks by wetting the fittings with soapy water. Anywhere that bubbles appear or grow indicates a leak in the connection. If a leak exists at a fitting then turn off the tank valve and tighten the fitting. Turn the gas back on and recheck with soapy water again. If the leak continues or if the leak is not at a fitting then do not use the generator and contact customer service.

NOTICE

  • When using standard 20 or 30 pound capacity LPG tanks, make sure they have Type 1, right hand Acme threads.
  • Verify the requalification date on the tank has not expired.
  • All new tanks must be purged of air and moisture prior to filling. Used tanks that have not been plugged or kept closed must also be purged
  • The purging process should be done by a LPG supplier. (Tanks from an exchange supplier should have been purged and filled properly already)
  • Always position the tank so the connection between the valve and the gas inlet won't cause sharp bends or kinks in the hose.


Do not start generator if you smell propane. This may result in explosion hazard. Do not use provided LPG hose for any other appliances. Always turn off the propane tank and disconnect LPG hose when not in use.

CONNECTING TO LARGE LPG/PROPANE TANK


BEFORE CONNECTING PROPANE TANK TO THE GENERATOR PLEASE REVIEW FUEL SAFETY SECTION
You can hook up you Duel Fuel Generator to a large home LP tank. It is required that you consult a plumber to properly connect your generator to the tank.
To properly connect with a large propane tank you must first check and confirm the LP fuel pressure at the outlet of the LP tank. The LP fuel pressure should be 14-10" of water column, which is the standard fuel pressure for residential gas fired appliances.
If the LP fuel pressure is within the 14-10" water column range, the primary fuel regulator should be removed from the fuel line components. Then plumb directly from the LP tank to the secondary regulator assembled to the generator.

You must consult a certified plumber to connect to large LP tank safely.

BEFORE STARTING THE GENERATOR


BEFORE STARTING THE GENERATOR, REVIEW SAFETY SECTION STARTING.
Before attempting to start the generator, verify the following:

  • The engine is filled with engine oil.
  • The generator is situated in a proper location.
  • The generator is on a dry surface.
  • All loads are disconnected from the generator.
  • The generator is properly grounded.
  • Propane connection is secure with no leaks or damage.


Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.
Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only operate the generator outside and away from windows, doors and vents.
NOTICE
The engine is equipped with a low oil shutdown switch. If the oil level becomes low, the engine may shut down and not start until the oil is filled to the proper level. Poor oil quality may interfere with the operation of the low oil shutdown switch.
The owner of the generator is responsible to ensure the proper oil level is maintained during the operation of the generator. Failure to maintain the proper oil level can result in engine damage.
NOTICE
When operating on LPG it is common for frost to form on the tank and regulators. This is not an indication of a problem. The amount of frost that forms can be affected by the size of the container, the amount of fuel being used, the humidity of the air and other operating conditions. In standard use this frost may reduce flow of gas and lower performance. If frost becomes an issue try exchanging fuel tanks to allow the first tank to warm up. You can also temporarily warm the tank up by pouring warm water over the top of the propane tank.

SWITCHING FUEL SOURCES

If you are switching fuel sources make sure to shut the generator down first and follow instructions on starting with your desired fuel source.
NOTICE
If you do not plan on operating the unit on propane do not leave the propane tank valve open. When starting on propane the engine may run rough for a few seconds while it purges gasoline in the carburetor.

POWER OUTPUT AND DEMAND

120-Volt AC devices have two different electric power demands that must be taken into consideration, namely the running power and the starting/peak power. Both are measured in Watts (typically abbreviated as "W").
The steady state continuous load is the running power demand and this is often marked on the device near its model number or serial number. Sometimes the device might only be marked with its voltage (i.e. 120 V) and current draw (e.g. 6 Amp or 6 A), in which case the running power demand in Watts can be obtained by multiplying the voltage times the current, e.g. 120 V × 20 A = 2,400 W.
Simple resistive 120-Volt AC devices such as incandescent bulbs, toasters, heaters, etc. have no extra power demand when starting, and so their starting power demands are the same as their running power demands.
More complex 120-Volt AC devices containing inductive or capacitive elements such as electric motors have a momentary extra power demand when starting, which can be up to seven times the running power demand or more. Manufacturers of such devices rarely publish this starting power demand and so it's often necessary to estimate it. A rule of thumb for devices fitted with an electric motor is to apply a starting power multiplier of 1.2 for small hand-held or portable devices and a value of 3.5 for larger stationary devices. For example, a 900 W angle grinder can be assumed to have a starting power demand of at least 1.2 × 900 W, which equals 1,080 W. Similarly, a 1,650 W air compressor can be assumed to have a starting power demand of at least 3.5 × 1,650 W, which equals 5,775 W.
To prevent overloading of the generator's 120-Volt AC system:

  1. Add up the running power demand of all the 120-Volt AC devices that will be connected to the generator at one time. This total must not be greater than the generator's specified running power output.
  2. Add up the running power demand again, but for the largest motor-driven device use the value of its starting power demand instead of its running power demand. This total must not be greater than the generator's specified starting power output.
  3. The total running power demand of all the devices that will be connected to any one of the generator's outlets must not exceed the generator's specified running power output or 3,700 W, whichever is the lesser.

STARTING THE GENERATOR ON GAS

  1. Move generator to a flat surface outside in a well ventilated area.
  2. Check oil levels.
  3. Verify the battery is connected and both battery cables are attached to their corresponding polarity.
  4. Disconnect all electrical loads from the generator.
  5. Confirm there is gas in the tank.
  6. Make sure the circuit breakers are properly set.
    1. Operating Position
    2. Tripped Position
  7. Move the fuel shut off valve to the ON position.
  8. Move the fuel selector switch to Gasoline.
  9. Move the choke lever to the ON position.
  10. Choose starting method:
    1. Electric Start: Push and hold the engine control switch in the START position until the engine starts. Once the engine starts, release the engine control switch; the switch will automatically move into the RUN position.

      NOTICE
      Failure to release the engine control switch once the engine starts could result in damage to the generator.
      Never push the engine control switch to the START position while the engine is running' this could damage the generator.
      Note: If the engine fails to start after 5 seconds, release the engine control switch. Let the generator sit idle for 15 seconds and then repeat step 10a. If the cranking speed drops after each unsuccessful attempt, then the battery may not be adequately charged. Manually start the generator in step 10b.
    2. Manual Start: Make sure the engine control switch is in the RUN position. Firmly grasp and pull the recoil handle slowly until you feel increased resistance. At this point, apply a rapid pull while pulling up and slightly away from the generator.
  11. As the engine starts and stabilizes, gradually move the choke lever back to the OFF position.

STARTING THE GENERATOR ON PROPANE

  1. Move generator to a flat surface outside in a well ventilated area.
  2. Check oil levels.
  3. Verify the battery is connected and both battery cables are attached to their corresponding polarity.
  4. Disconnect all electrical loads from the generator.
  5. Make sure the circuit breakers are properly set (see Figure 7).
  6. Move the fuel shut off valve to the OFF position.
  7. Switch fuel selector on control panel to Propane.
  8. Move the choke to the OFF position.
  9. Make sure LPG hose is safely secured from generator to tank and tank valve is open.
  10. Choose starting method.
    1. Electric Start: Push and hold the engine control switch in the START position until the engine starts. Once the engine starts, release the engine control switch; the switch will automatically move into the RUN position.
      NOTICE
      Failure to release the engine control switch once the engine starts could result in damage to the generator.
      Never push the engine control switch to the START position while the engine is running' this could damage the generator.
      Note: If the engine fails to start after 5 seconds, release the engine control switch. Let the generator sit idle for 15 seconds and then repeat step 10a. If the cranking speed drops after each unsuccessful attempt, then the battery may not be adequately charged. Manually start the generator in step 10b.
    2. Manual Start: Make sure the engine control switch is in the RUN position. Firmly grasp and pull the recoil handle slowly until you feel increased resistance. At this point, apply a rapid pull while pulling up and slightly away from the generator.

STOPPING THE GENERATOR

Normal Operation
During normal operation, use the following steps to stop START your generator:

  1. Remove any connected loads from the control panel receptacles.
  2. Allow the generator to run at "no load" to reduce and stabilize engine and alternator temperatures.
  3. Position the engine control switch to STOP (see figure 17). If you plan to store the generator after use, turn the fuel shutoff valve to the OFF position and allow the fuel to be consumed from the carburetor.
  4. If running on propane, make sure to close valve on propane tank.

During an Emergency
If there is an emergency and the generator must be stopped quickly, position the engine control switch to the STOP position immediately.

MAINTENANCE


BEFORE PERFORMING MAINTENANCE ON THE GENERATOR, REVIEW THE SAFETY SECTION STARTING ON PAGE 5, AS WELL AS THE FOLLOWING SAFETY MESSAGES.

Avoid accidentally starting the generator during maintenance by removing the spark plug boot from the spark plug. For electric start generators, also disconnect the battery cables from the battery (disconnect the black negative (-) cable first) and place the cables away from the battery posts to avoid arcing.
burn hazard Allow hot components to cool to the touch prior to performing any maintenance procedure.
Internal pressure can build in the engine crankcase while the engine is running. Removing the oil fill plug/ dipstick while the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin. Allow engine oil to cool for several minutes before removing the oil fill plug/dipstick.
Always perform maintenance in a wellventilated area. Gasoline fuel and fuel vapors are extremely flammable and can ignite under certain conditions.

MAINTENANCE SCHEDULE


Failure to perform periodic maintenance or not following maintenance procedures can cause the generator to malfunction and could result in death or serious injury.
NOTICE
Periodic maintenance intervals vary depending on generator operating conditions. Operating the generator under severe conditions, such as sustained high-load, high-temperature, or unusually wet or dusty environments, will require more frequent periodic maintenance. The intervals listed in the maintenance schedule should be treated only as a general guideline.


Avoid skin contact with engine oil or gasoline. Prolonged skin contact with engine oil or gasoline can be harmful. Frequent and prolonged contact with engine oil may cause skin cancer. Take protective measures and wear protective clothing and equipment. Wash all exposed skin with soap and water.
Following the maintenance schedule is important to keep the generator in good operating condition. The following is a summary of maintenance items by periodic maintenance intervals.

TABLE 1: MAINTENANCE SCHEDULE - OWNER PERFORMED

Maintenance Item Before Every Use After First 20 Hours or First Month of Use After 50 Hours of Use or Every 6 Months After 100 Hour of Use or Every 6 Months After 300 Hours of Use or Every Year
Engine Oil Check Level Change Change - -
Cooling Features Check/Clean - - - -
Air Filter Check - Clean* - Replace
Spark Plug - - - Check/Clean Replace
Spark Arrestor - - - Check/Clean -

*Service more frequently if operating in dry and dusty conditions

TABLE 2: MAINTENANCE SCHEDULE - AUTHORIZED WESTINGHOUSE SERVICE DEALER PERFORMED

Maintenance Item Before Every Use After First 20 Hours or First Month of Use After 50 Hours of Use or Every 6 Months After 100 Hour of Use or Every 6 Months After 300 Hours of Use or Every Year
Valve Clearance - - - - Check/Adjust
Fuel Filter - - - Check/Clean -

MAINTENANCE REMINDERS


The VFT meter on this unit has programmed maintenance reminders. When the VFT meter shows:
This is to remind you to change the oil after the initial 25 hours of run time.
It is time to clean the air filter.
It is time change/clean the fuel filter, clean the air filter, and change the oil.

CLEANING THE SPARK ARRESTOR


burn hazard Hot Surfaces. When operating machine, do not touch hot surfaces. Keep machine away from combustibles during use. Hot surfaces could result in severe burns or fire.
Check and clean the spark arrestor after every 100 hours of use or 6 months.

  1. Generator must be cold to perform this maintenance.
  2. Move the inverter to a flat, level surface.
  3. Remove the 6 screws holding the muffler cover in place.
  4. Once the cover is removed, locate the screw on the tip of the muffler and remove. Pull the spark arrestor out of the muffler.
  5. If the spark arrestor screen shows signs of wear (rips, tears or large openings in the screen), replace the spark arrestor screen. NOTE: Only use Westinghouse spark arrestors as replacements.
  6. If screen is not torn then clean using a wire brush, commercial solvent, or compressed air. Remove any dirt and debris that may have collected on the spark arrestor screen.
  7. Install the spark arrestor back into the muffler. Make sure to fully push it in so that it is tight on the tip of the muffler.
  8. Replace the muffler cover and tighten all 6 screws.

DRAINING CARBURETOR FLOAT BOWL

  1. Make sure the generator is off and you are away from any open flames.
  2. Place pan (or suitable container) under the carburetor assembly.
  3. Loosen screw at bottom of the bowl and allow gas to drain out.
  4. After all the gas has drained out, tighten the screw.

ENGINE OIL MAINTENANCE

Engine Oil Specification

  1. Only use the engine oil specified in Figure 21.
  2. Only use 4-stroke/cycle engine oil. NEVER USE 2-STROKE/CYCLE OIL. Synthetic oil is an acceptable substitute for conventional oil.
    Recommended Oil

CHECKING ENGINE OIL

NOTICE
Always maintain proper engine oil level. Failure to maintain proper engine oil level could result in severe damage to the engine and/or shorten the life of the engine. Always use the specified engine oil. Failure to use the specified engine oil can cause accelerated wear and/or shorten the life of the engine.
Engine oil level should be checked before every use.

  1. Always operate or maintain the generator on a flat surface.
  2. Stop engine if running.
  3. Let engine sit and cool for several minutes (allow crankcase pressure to equalize).
  4. With a damp rag, clean around the oil fill plug/dipstick.
  5. Remove oil fill plug/dipstick.
  6. Check oil level: When checking the engine oil, remove the oil fill plug/dipstick and wipe it clean. Thread the oil fill plug/dipstick all the way back in and then remove and check the oil level on the oil fill plug/dipstick.
    • Acceptable Oil Level – Oil is visible on the crosshatches between the H and L lines on the oil fill plug/dipstick.
      Checking Oil Level
    • Low Oil – Oil is below the L line on the oil fill plug/ dipstick.

ADDING ENGINE OIL

  1. Always operate or maintain the generator on a flat surface.
  2. Stop engine if running.
  3. Let engine sit and cool for several minutes (allow crankcase pressure to equalize).
  4. Thoroughly clean around the oil fill plug/dipstick.
  5. Remove oil fill plug/dipstick and wipe clean.
  6. Select the proper engine oil as specified in Figure 21.
  7. Using the supplied funnel and tube, slowly add engine oil to the engine. Stop frequently to check the level to avoid overfilling.
  8. Continue to add oil until the oil is at the correct level (see Figure 23).

CHANGING ENGINE OIL

  1. Stop the engine.
  2. Let engine sit and cool for several minutes (allow crankcase pressure to equalize).
  3. Place oil pan (or suitable container) under the oil drain plug (see Figure 24).
  4. With a damp rag, thoroughly clean around the oil drain plug.
  5. Remove the oil drain plug (see Figure 24). Once removed, place the oil drain plug on a clean surface.
  6. Allow oil to completely drain.
  7. Replace oil drain plug.
  8. Fill crankcase with oil following the steps outlined in Adding Engine Oil.

NOTICE
Never dispose of used engine oil by dumping the oil into a sewer, on the ground, or into ground water or waterways. Always be environmentally responsible. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility.

AIR FILTER MAINTENANCE


Never use gasoline or other flammable solvents to clean the air filter. Use only household detergent soap to clean the air filter.

Cleaning the Air Filter
The air filter must be cleaned after every 50 hours of use or 3 months (frequency should be increased if generator is operated in a dusty environment).

  1. Turn off the generator and let it cool for several minutes if running.
  2. Move the generator to a flat, level surface.
  3. Unclip the clips on the top and bottom of the air filter cover.
  4. Remove the black coarse air filters.
  5. Wash the foam air filter elements by submerging the elements in a solution of household detergent soap and warm water. Slowly squeeze the foam to thoroughly clean.
    NOTICE
    NEVER twist or tear the foam air filter element during cleaning or drying. Only apply slow but firm squeezing action.
  6. Rinse in clean water by submerging the air filter elements in fresh water and applying a slow squeezing action
    NOTICE
    Never dispose of soap cleaning solution used to clean the air filter by dumping the solution into a sewer, on the ground, or into ground water or waterways. Always be environmentally responsible. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility.
  7. Dispose of used soap cleaning solution properly.
  8. Dry the air filter elements by again applying a slow firm squeezing action.
  9. Once the air filters are dry, coat the air filters with clean engine oil.
  10. Squeeze the filters to remove any excess oil.
  11. Install the filters back into the unit. If there are two filters make sure the gray (fine) air filter goes in first followed by the black (coarse) air filter on the outside.
  12. Install the air filter cover and secure the air filter assembly.

SPARK PLUG MAINTENANCE

The spark plug must be checked and cleaned after every 100 hours of use or 6 months and must be replaced after 300 hours of use or every year.

  1. Stop the generator and let it cool for several minutes if running.
  2. Move the generator to a flat, level surface.
  3. Remove the spark plug boot by firmly pulling the plastic spark plug boot handle directly away from the engine.
    Remove Spark Plug Boot
    NOTICE
    Never apply any side load or move the spark plug laterally when removing the spark plug. Applying a side load or moving the spark plug laterally may crack and damage the spark plug boot.
  4. Clean area around the spark plug.
  5. Using the 13/16" spark plug socket wrench provided, remove the spark plug from the cylinder head.
  6. Place a clean rag over the opening created by the removal of the spark plug to make sure no dirt can get into the combustion chamber.
    • Inspect the spark plug for:
    • Cracked or chipped insulator
    • Excessive wear
    • Spark plug gap (the acceptable limit of 0.027–0.032 in. [0.70 – 0.80 mm]).

NOTICE
Use only recommended spark plugs when servicing. The manufacturer is not responsible for engine damage when using spark plugs not recommended by the manufacturer.

  1. Install the spark plug by carefully following the steps outlined below:
    1. Carefully insert the spark plug back into the cylinder head. Hand-thread the spark plug until it bottoms out.
    2. Using the 13/16" spark plug socket wrench provided, turn the spark plug to ensure it is fully seated.
    3. Replace the spark plug boot, making sure the boot fully engages the spark plug's tip.

Recommended Spark Plug Replacement:
NGK: (1034) BP7ES (Replacement)
Torch: F7TC (OE Spark Plug)
Westinghouse Part Number: 180526

CHECKING AND ADJUSTING VALVE LASH


Checking and adjusting valve lash must be done when the engine is cold.

  1. Remove the rocker arm cover and carefully remove the gasket. If the gasket is torn or damaged, it must be replaced.
  2. Remove the spark plug so the engine can be rotated more easily.
  3. Rotate the engine to top dead center (TDC) of the compression stroke. Looking through the spark plug hole, the piston should be at the top.
  4. Both the rocker arms should be loose at TDC on the compression stroke. If they are not, rotate the engine 360°.
  5. Insert a feeler gauge between the rocker arm and the push rod and check for clearance (see Figure 29). See Table 1 for valve lash specifications
    1. Push Rod,
    2. Feeler Gauge Area
    3. Rocker Arm,
    4. Jam Nut,
    5. Adjusting Nut

(Table 1) Standard Valve Lash

Intake Valve Exhaust Valve
Valve Lash 0.0035 ± 0.0043 in
(0.09 ± 0.11 mm)
0.0043 ± 0.0051 in
(0.11 ± 0.13 mm)
Bolt Torque 8-12N.m 8-12N.m
  1. If an adjustment is required, hold the adjusting nut and loosen the jam nut.

TESTING GFCI OUTLETS

  1. Start the generator and allow it to warm up.
  2. Press the test button on the GFCI outlet.
  3. The reset button should pop out and there will be no power from the outlets. If the reset button does not pop out, the GFCI outlet is not working correctly and must be repaired before the generator can be operated.
  4. Press the reset button to restore power to the outlet.

BATTERY REPLACEMENT

  1. Remove the spark plug wire from spark plug.
  2. Remove the battery quick connect plugs.
  3. Loosen and remove the bolt on the battery hold- down plate and swing the plate out.
  4. Tip the battery forward slightly to access battery cables.
  5. Disconnect the black negative (-) battery cable from the battery first.
  6. Disconnect the red positive (+) battery cable second and remove the battery.
    NOTICE
    Dispose of the used battery properly according to the guidelines established by your local or state government.
  7. Install the new battery into the generator frame.
  8. Connect the red positive (+) battery cable to the battery first.
  9. Connect the black negative (-) battery cable to the battery second. Then connect the battery quick connect plugs.
  10. Install the battery hold-down plate using the nuts removed in step 2.
  11. Install the spark plug wire onto spark plug.

See below for the battery specification when replacing the battery.

Westinghouse Part No. 100557
After Market Battery Model YT9A
Volts 12
Amp Hr 9
Dimensions 5 5/16in by 3in by 5 3/8in

CLEANING THE GENERATOR

It is important to inspect and clean the generator before every use.
Clean All Engine Air Inlet and Outlet Ports – Make sure all engine air inlet and outlet ports are clean of any dirt and debris to ensure the engine does not run hot.
Clean All Engine Cooling Fins – Use a damp rag and a brush to loosen and remove all dirt on or around the engine's cooling fins.
Clean All Alternator Cooling Air Inlets and Exhaust Ports – Make sure the cooling air inlets and exhaust ports of the alternator are free of any debris and obstructions. Use a vacuum cleaner to remove dirt and debris stuck in the cooling air inlets and exhaust ports.
General Cleaning of the Generator – Use a damp rag to clean all remaining surfaces.

STORAGE

STORING GENERATOR


Never store a generator with fuel in the tank indoors or in a poorly ventilated area where the fumes can come in contact with an ignition source such as a: 1) pilot light of a stove, water heater, clothes dryer or any other gas appliance; or 2) spark from an electric appliance.
NOTICE
Gasoline stored for as little as 60 days can go bad, causing gum, varnish and corrosive buildup in fuel lines, fuel passages and the engine. This corrosive buildup restricts the flow of fuel, preventing an engine from starting after a prolonged storage period.
Proper care should be taken to prepare the generator for any storage.

  1. Make sure the Engine Switch is switched to STOP.
  2. Disconnect the battery.
  3. Clean the generator as outlined in Cleaning the Generator.
  4. Drain all gasoline from the fuel tank as best as possible.
  5. With the fuel shut off valve open, start the engine and allow the generator to run until all the remaining gasoline in the fuel lines and carburetor is consumed and the engine shuts off.
  6. Close the fuel shut off valve.
  7. Change the oil (see Changing Engine Oil).
  8. Remove the spark plug (see Spark Plug Maintenance) and place about 1 tablespoon of oil in the spark plug opening. While placing a clean rag over the spark plug opening, slowly pull there coil handle to allow the engine to turn over several times. This will distribute the oil and protect the cylinder wall from corroding during storage.
  9. Replace the spark plug (see Spark Plug Maintenance).
  10. Move the generator to a clean, dry place for storage.

TROUBLESHOOTING


Before attempting to service or troubleshoot the generator, the owner or service technician must first read the owner's manual and understand and follow all safety instructions. Failure to follow all instructions may result in conditions that can lead to voiding of the EPA certification or product warranty, serious personal injury, property damage or even death.

PROBLEM POTENTIAL CAUSE SOLUTION
Engine is running, but no electrical output
  1. Circuit breakers are tripped.
  2. The power cord's plug connector is not fully engaged in the generator's outlet.
  3. Faulty or defective power cord
  4. Faulty or defective electrical appliance
  5. GFCI outlet is tripped
  6. If trying 1-5 above does not solve the problem, the cause might be the generator has a fault.
  1. Reset the circuit breakers and check for overload condition.
  2. Verify plug connector is firmly engaged in the generator's outlet. If using the 240V outlet, make sure plug connector is rotated 1/4 turn in the clockwise direction.
  3. Replace power cord.
  4. Try connecting a known good appliance to verify the generator is producing electrical power.
  5. Press the reset button on the GFCI outlet.
  6. Take the generator to your nearest authorized service dealer.
Engine will not start or remain running while trying to start.
  1. Fuel shutoff valve is in the OFF position.
  2. Generator is out of gasoline.
  3. Fuel flow is obstructed.
  4. Unit is over choked.
  5. Starting battery may have insufficient charge
  6. Dirty air filter
  7. Low oil level shut down switch is preventing the unit from starting.
  8. Spark plug boot is not fully engaged with the spark plug tip.
  9. Spark plug is faulty.
  10. Dirty/plugged spark arrestor
  11. Stale fuel
  12. If trying 1-11 above does not solve the problem, the cause might be the generator has a fault.
  1. Move the fuel shut off valve to the ON position.
  2. Add gasoline to the generator.
  3. Inspect and clean fuel delivery passages.
  4. Move the choke lever halfway between the ON and OFF positions.
  5. On electric start models only. Check battery output and charge battery as necessary.
  6. Check and clean the air filter.
  7. Check oil level and add oil if necessary.
  8. Firmly push down on the spark plug boot to ensure the boot is fully engaged
  9. Remove and check the spark plug. Replace if faulty.
  10. Check and clean the spark arrestor.
  11. Drain fuel and replace with fresh fuel.
  12. Take the generator to your nearest authorized service dealer.
Generator suddenly stops running.
  1. Generator is out of fuel.
  2. The low oil shut down switch has stopped the engine.
  3. Too much load
  4. If trying 1-3 above does not solve the problem, the cause might be a fault in the generator.
  1. Check fuel level. Add fuel if necessary.
  2. Check oil level and add oil if necessary.
  3. Restart the generator and reduce the load.
  4. Take the generator to your nearest authorized service dealer.
Engine runs erratic; does not hold a steady RPM.
  1. Choke was left in the ON position.
  2. Dirty air filter
  3. Applied loads maybe cycling on and off
  4. If trying 1-3 above does not solve the problem, the cause might be a fault in the generator
  1. Move choke to the OFF position
  2. Clean the air filter.
  3. As applied loads cycle, changes in engine speed may occur; this is a normal condition.
  4. Take the generator to your nearest authorized service dealer.

WH10000DF EXPLODED VIEW

Exploded view

WH10000DF EXPLODED VIEW PART NO.

NO. PART. DESCRIPTION
1 NA FRAME
2 NA ISOLATOR
3 NA METAL CAP
4 100520 NUT M8
5 180524 NUT M8
6 140508 CLIP, FUEL LINE Φ7.5
7 180563 BRACKET,AIR CLEANER
8 120505 BOLT M6X12
9 110504 MUFFLER BRACKET
10 300837 ENGINE ASSY
11 300836 PANEL COMP
11.1 130542 ON/OFF/RUN SWITCH
11.2 130158 VFT METER
11.3 300674 GROUND TERMINAL ASSEMBLY
11.4 130512 DOUBLE SOCKET. 5-20R/UL
11.5 130564 THERMAL PROTECTOR 20A
11.6 300838 THERMAL PROTECTOR 33A
11.7 130505 L14-30 RECEPTACLE
12 180562 DUSTPROOF SHEET
13 100516 BOLT M8X16
14 120501 ALTERNATOR ASSY
14.1 130533 CARBON BRUSH ASSEMBLY
14.2 120503 GROUNDING POST COMP.
15 120504 MOTOR STAND
16 100540 GASKET, ROTOR BOLT Φ10.5×Φ30×4
17 120514 BOLT M10X1.25X283
18 120513 BOLT M6X200
19 300115 CLIP, FUEL LINE Φ9.5
20 15053 FILTER,FUEL
21 120537 BOLT M5X12
22 120517A AUTOMATIC VOLTAGE REGULA- TOR
23 120519 END COVER,GENERATOR
24 110501 GASKET, EXHAUST PIPE
25 110502 SPRING WASHER Ф8
26 110500 MUFFLER COMP
27 150500 FUEL TANK ASSEMBLY
27.1 150529 FUEL STRAINER
27.2 230514 FUEL GAUGE
28 120541 BOLT M6X25
29 150501 WASHER FUEL TANK
30 150512 CARBON TANK COMP
31 120542 FRAME WIRE
32 NA TOOTH TYPE GASKET Ф8
33 150505 FUEL TANK CAP COMP
34 150552 FUEL COCK
35 100547 WASHER
36 160513 THE CARBON TANK IS CON- NECTED WITH THE AIR FILTER
37 100548 NUT M6
38 100594 VALVE
39 100512 FOOT BRACKET
40 100515 VIBRATION ISOLATION PAD, SQUARE
41 100582 BOLT M6X28
42 100510 FLAT WASHER Φ13XΦ37X4
43 100506 WHEEL
44 190311 AXLE
45 100508 COTTER PIN
46 100527 PLUG, HANDLE
47 100525 BOLT, HANDLE M10XΦ12.5X53.5
48 100521 HANDLE ASSEMBLY
49 100523 RUBBER, HANDLE
50 120509 BOLT M5X230
51 120510 NUT M5
52 120511 FLAT WASHER Ф5
53 120512 SPRING WASHER Ф5
54 180561 GUARD COVER, CRANKCASE
55 110503 BOLT M8X30
56 120518 BOLT M5X16
57 NA CLIP, FUEL LINE Ф8
58 100558 BATTERY HOLDER
59 NA NUT M5
60 120516 GROUNDING WIRE
61 300839 BATTERY CABLE KIT
62 100595 COVER, LPG REGULATOR
63 100557 BATTERY
64 130535 HEXAGON PATTERN PAN HEAD SCREWS
65 100551 NUT M10
66 130536 BOLT M6X16
67 NA LOCK NUT M6
68 130538 FUEL SELECTOR SWITCH
69 100586 LOW PRESSURE PIPE FROM SWITCH
70 100587 LOW PRESSURE PIPE SHORT
71 NA CLIP Φ12
72 100589 FUEL HOSE FROM FUEL COCK
73 100590 FUEL HOSE
74 100596 RELIEF VALVE ASSEMBLY
NA 230523 1.1L OIL BOTTLE
NA 10003 WH10000DF Owners Manual

Westinghouse Generator Accessories (call to order)

210004 GENERATOR COVER
3013425C 25' GENERATOR CORD: 30A 120V TT-30P TO TT-30R
3013450C 50' GENERATOR CORD: 30A 120V TT-30P TO TT-30R
3015425C 25' GENERATOR CORD: 30A 120V L5-30P TO TT-30R
30151425C 25' GENERATOR CORD: 30A 120V L5-30P TO (3X) 5-20R
3021225C 25' GENERATOR CORD: 30A 120V L14-30P TO L14-30R
3021250C 50' GENERATOR CORD: 30A 120V L14-30P TO L14-30R
5027825C 25' GENERATOR CORD: 50A 120/240V 14-50P TO 14-50R
5027850C 50' GENERATOR CORD: 50A 120/240V 14-50P TO 14-50R
30211625C 25' GENERATOR CORD: 30A 120V L14-30P TO (4X) 5-20R
30211650C 50' GENERATOR CORD: 30A 120V L14-30P TO (4X) 5-20R
30114A GENERATOR PLUG ADAPTER: 30A 120V L14-30P TO TT-30R
50218A GENERATOR PLUG ADAPTER: 50A 120/240V L14-30P TO 14-50RR
302116A GENERATOR PLUG ADAPTER: 30A 120V L14-30P TO (4X) 5-20R
30154A GENERATOR PLUG ADAPTER: 30A 120V L5-30P TO TT-30R
30136A GENERATOR PLUG ADAPTER: 30A 120V TT-30P TO L5-30R
301514A GENERATOR PLUG ADAPTER: 30A 120V L5-30P TO (3X) 5-20R
30194A GENERATOR PLUG ADAPTER: 30A 120V 5-20P TO TT-30R
30196A GENERATOR PLUG ADAPTER: 30A 120V 5-20P TO L5-30R
50158A GENERATOR PLUG ADAPTER: 30A 120V L5-30P TO 14-50R
50138A GENERATOR PLUG ADAPTER: 30A 120V TT-30P TO 14-50R

WH10000DF ENGINE VIEW

Engine view

WH10000DF ENGINE PART NO.

NO. PART. DESCRIPTION
1 190223 THE CRANKSHAFT BOX BODY
2 180593 BEARING
3 180504 THE CRANKSHAFT OIL SEAL
4 190412 PENDULUM STEM SEAL
5 190410 SWINGING ROD
6 190409 SWINGING ROD GASKET
7 190408 CHECK BACK CLIP
8 180507 OIL DRAIN BOLT
9 180508 OIL DRAIN BOLT WASHER
10 180586 OIL SENSOR
11 130536 BOLT WITH DISC M6X16
12 180604 POSITIONING PIN OF CRANKCASE
13 190407 THE PISTON
14 190406 PISTON RING ASSEMBLY
15 180072 CONNECTING ROD ASSEMBLY
16 190404 THE PISTON PIN
17 180791 PISTON PIN RETAINER
18 180512 CRANKCASE COVER
19 180530 BEARING
20 190225 CENTRIFUGAL GOVERNOR GEAR ASSEMBLY
21 180514 CYLINDER HEAD
22 180794 INLET VALVE
23 180795 THE EXHAUST VALVE
24 180752 LOWER SEAT OF INLET VALVE SPRING
25 180573 VALVE SEAL
26 190224 VALVE SPRINGS
27 170504 LINE PRESSING BLOCK
28 180755 EXHAUST VALVE SPRING SEAT
29 NA LIMIT PLATE ASSEMBLY
30 180799 ROCKER ARM
31 180756 HAT
32 140503 INTAKE STUD
33 180571 EXHAUST STUD
34 180522 EXHAUST GASKET
35 180531 OIL GAUGE ASSEMBLY
36 110502 SPRING WASHERS PHI 8
37 180524 NUT M8
38 300797 CARBURETOR ASSEMBLY
39 180515 CONTROL ARM
40 180616 WIRE HARNESS CLIP
41 100548 NUT M6
42 190403 THE CRANKSHAFT
43 190402 THE VALVE LIFTER
44 180511 CRANKCASE GASKET
45 190401 BALANCE SHAFT
46 180806 CAMSHAFT ASSEMBLY
47 180807 COIL BOLT M8X35
48 180808 BOLT WITH DISC M8X40
49 180742 CYLINDER HEAD PIN
50 180513 CYLINDER HEAD GASKET
51 180523 COIL BOLT M10X80
52 180526 THE SPARK PLUG
53 180810 THE VALVE PUSH ROD
54 180811 WIND DEFLECTOR
55 120505 BOLT WITH DISC M6X12
56 180527 CYLINDER CRANIUM
57 180528 CYLINDER HEAD COVER GASKET
58 180529 CYLINDER HEAD COVER FASTENING BOLTS
59 180519 SPEED CONTROL CONTROLLER
60 180503 THE FLYWHEEL COMPONENTS
61 180502 THE IMPELLER
62 180501 START THE CUP
63 180500 THE FLYWHEEL NUT
64 180510 RUBBER LEAD
65 180584 IGNITER
66 100518 M6X25 FOOT SCREW FOR PADS TO LEGS
67 140504 INTAKE GASKET
68 140502 INSULATOR,CARBURETOR
69 140509 CARBURETOR GASKET
70 180636 ROCKER ARM FASTENING BOLT ASSEMBLY
71 180521 THE MUFFLER CONNECTS THE PIPE
72 180516 THE THROTTLE LEVER
73 180517 VERNIER C SPRING
74 170500 HOOD ASSEMBLY
74.1 100523 PULL HANDLE
75 160500 AIR FILTER ELEMENT
75.1 160006 AIR CLEANER ELEMENT
76 180533 EXHAUST PIPE
77 180518 SPEED REGULATING SPRING B
78 140537 EMPTY FILTER GASKET
79 170502 Q TYPE LINE CARD
80 140506 FUEL PIPE RUBBER
81 170506 CLAMPER CORD A
82 180589 BOLT WITH DISC M6X8
83 170503 STARTING MOTOR ASSEMBLY
84 180744 VALVE LOCK CLAMP
85 100589 FUEL PIPE
86 140508 FUEL PIPE CLAMP RING Ф 7.5
87 180506 CHARGING COIL
88 100636 BOLT M6X30
89 NA Q TYPE LINE CARD
NA 140571 HIGH ALTITUDE CARBURETOR KIT 420CC (SOLD SEPARATE)
NA 140565 HIGH ALTITUDE REGULATOR KIT (SOLD SEPARATE)
NA 140008 FUEL SOLENOID
NA 170040 STARTING SOLENOID
NA 300504 SPARK ARRESTOR
NA 210002 SPARK PLUG TOOL WRENCH
NA 180233 SPARK PLUG BOOT

WH10000DF SCHEMATIC

WestinghouseOutdoorPower.com
Service Hotline: (855) 944-3571

777 Manor Park Drive
Columbus, OH 43228

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Westinghouse WH10000DF - Portable Generator Manual

Advertisement

Need Assistance?

Do you have a question about the WH10000DF that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents