Stopping The Generator; Normal Operation; During An Emergency - Westinghouse WH3250 Owner's Manual

Hide thumbs Also See for WH3250:
Table of Contents

Advertisement

Available languages

Available languages

NOTE:
If the engine fails to start after 5 seconds,
release the engine control
switch. Let the
generator
sit idle for 15 seconds
and then
repeat step 5. If the cranking
speed drops
after each unsuccessful
attempt, then the
battery
may not be adequately
charged.
Manually start the generator
as instructed
in Manuah'y Starting a Generator
on page
24.
NOTE:
The electric start generator
is equipped
with a battery charging
feature. Once
the engine is running, a small charge is
supplied
to the battery via the battery
cables and will slowly
recharge the battery.
6.
As the engine starts and stabilizes, gradually move
the choke lever back to the OFF position.
STOPPING
THE GENERATOR
Normal
Operation
During normal operation, use the following steps to stop
your generator:
1.
Remove any connected loads from the control
panel receptacles.
2.
Allow the generator to run at "no load" to reduce
and stabilize engine and alternator temperatures.
3.
Push the engine control switch to the OFF position.
4.
Turn the fuel shutoff valve to the OFF position.
During
an Emergency
If there is an emergency and the generator must be
stopped quickly, push the engine control switch to the
OFF position immediately.
27

Advertisement

Chapters

Table of Contents
loading

Table of Contents