Main/Aux. Serial Interface and I/O Connector

The DS6300 master/slave model is equipped with a 25-pin male D-sub connector for
connection to the host computer, power supply and input/output signals.
The DS6300 fieldbus models (Ethernet, DeviceNet, Profibus) adopt a 26-pin male connector
instead of the 25-pin one.
The details of the connector pins are indicated in the following table:
1
10
19
Figure 21 - 26-pin Connector
Pin
Name
1
Shield
20
RXAUX
21
TXAUX
8
OUT 1+
22
OUT 1-
11
OUT 2+
12
OUT 2-
16
OUT 3A
17
OUT 3B
18
EXT_TRIG A External trigger (polarity insensitive)
19
EXT_TRIG B External trigger (polarity insensitive)
6
IN2A
10
IN2B
14
IN3A
15
IN4A
24
IN_REF
9,13
VS
24,25,26* GND
Pin
2
3
4
5
7
* Pin 26 is only available for fieldbus models (Ethernet, DeviceNet, Profibus).
16
9
18
26
25-pin/26-pin D-sub connector pinout
Function
Cable shield - internally connected by capacitor to the chassis
Receive data of auxiliary RS232 (referred to GND)
Transmit data of auxiliary RS232 (referred to GND)
Configurable digital output 1 - positive pin
Configurable digital output 1 - negative pin
Configurable digital output 2 - positive pin
Configurable digital output 2 - negative pin
Configurable digital output 3 - polarity insensitive
Configurable digital output 3 - polarity insensitive
Input signal 2 (polarity insensitive)
Input signal 2 (polarity insensitive)
Input signal 3 (polarity insensitive)
Input signal 4 (polarity insensitive)
Common reference of IN3 and IN4 (polarity insensitive)
Supply voltage - positive pin
Supply voltage - negative pin
Main Interface Connector Pinout
RS232
TX
RX
RTS
CTS
GND_ISO
1
14
Figure 22 - 25-pin Connector
RS485 Full Duplex
TX485+
RX485+
TX485-
RX485-
GND_ISO
DS6300
13
25
RS485 Half Duplex
RTX485+
RTX485-
GND_ISO