1.7.3

Fieldbus Network

The Fieldbus (Ethernet, Profibus and DeviceNet) model offers connectivity without any
converter or adapter needed.
The DS6300 master Fieldbus communicates with a remote host (for ex. remote PC
connected via Internet) by means of a cable connected to the Fieldbus (Ethernet, Profibus or
DeviceNet) connector provided.
The local Lonworks 9-pin female connector connects the Fieldbus master reader to the first
slave reader of the system, while the 26 D-sub male connector may be connected to the
C-BOX 100 to supply the reader.
The slave readers (DS6300 master/slave models) are connected together through the local
Lonworks connectors. Only the 9-pin female connector of the last slave reader must be
terminated by the BTK-6000 terminator. No terminator must be inserted in the Fieldbus
master reader, since it is internally integrated.
Single P.S.
The DS6300 (Ethernet, DeviceNet or Profibus model) master is connected to a fieldbus
remote Host. It can be activated by a signal generated by the remote Host or be always
active if working in Automatic operating mode.
Slave 2
As described before, C-BOX 100 can supply a maximum number of 3 readers. Therefore, if
using more than 3 readers, connect the different groups by means of a cable (CAB6111X)
not bringing power to, and power each group individually.
12
Fieldbus
Master
CAB601X
P.S.
Slave 3
Figure 16 – Fieldbus Single P.S.
Remote Host
C-BOX 100
PWR120
DS6300