Mitsubishi Electric MXZ-2D33VA Service Manual page 484

Hide thumbs Also See for MXZ-2D33VA:
Table of Contents

Advertisement

MXZ-6D122VA HEATING
Indoor units
combination
Unit A
18+18+18+35+71
1.51
18+18+18+42+42
1.75
18+18+18+42+50
1.65
18+18+18+42+60
1.55
18+18+18+42+71
1.44
18+18+18+50+50
1.57
18+18+18+50+60
1.47
18+18+18+50+71
1.38
18+18+18+60+60
1.39
18+18+20+20+20
2.48
18+18+20+20+22
2.46
18+18+20+20+25
2.39
18+18+20+20+35
2.17
18+18+20+20+42
2.04
18+18+20+20+50
1.91
18+18+20+20+60
1.77
18+18+20+20+71
1.64
18+18+20+22+22
8
8
0
2.41
18+18+20+22+25
2.34
18+18+20+22+35
2.13
18+18+20+22+42
2.01
18+18+20+22+50
1.88
18+18+20+22+60
1.75
18+18+20+22+71
1.62
18+18+20+25+25
2.28
18+18+20+25+35
2.08
18+18+20+25+42
1.96
18+18+20+25+50
1.84
18+18+20+25+60
1.71
18+18+20+25+71
1.59
18+18+20+35+35
1.91
18+18+20+35+42
1.81
18+18+20+35+50
1.71
18+18+20+35+60
1.60
18+18+20+35+71
1.49
18+18+20+42+42
1.72
Heating Capacity (kW)
Unit B
Unit C
Unit D
Unit E
1.51
1.51
2.93
5.95
1.75
1.75
4.08
4.08
1.65
1.65
3.85
4.59
1.55
1.55
3.61
5.15
1.44
1.44
3.37
5.70
1.57
1.57
4.35
4.35
1.47
1.47
4.09
4.90
1.38
1.38
3.83
5.44
1.39
1.39
4.62
4.62
2.48
2.75
2.75
2.75
2.46
2.73
2.73
3.01
2.39
2.65
2.65
3.32
2.17
2.41
2.41
4.23
2.04
2.27
2.27
4.77
1.91
2.13
2.13
5.32
1.77
1.97
1.97
5.91
1.64
1.82
1.82
6.47
2.41
2.68
68
2.95
95
2.95
95
2.34
2.60
2.86
3.25
2.13
2.37
2.61
4.15
2.01
2.23
2.46
4.69
1.88
2.09
2.30
5.23
1.75
1.94
2.14
5.83
1.62
1.80
1.98
6.39
2.28
2.53
3.16
3.16
2.08
2.31
2.89
4.04
1.96
2.18
2.72
4.58
1.84
2.05
2.56
5.11
1.71
1.90
2.38
5.70
1.59
1.76
2.20
6.26
1.91
2.13
3.72
3.72
1.81
2.02
3.53
4.23
1.71
1.90
3.33
4.75
1.60
1.77
3.11
5.32
1.49
1.65
2.90
5.87
1.72
1.91
4.02
4.02
Unit F
Total
-
13.41
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.21
( 3.50 -
15.30 )
-
13.39
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.40
3 0
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.38
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
308/362
Outdoor unit
power consumpution
Current (A)
(kW)
3.06
13.45
( 0.77 -
4.87 )
3.02
13.25
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
2.90
12.74
( 0.77 -
4.57 )
3.05
13.41
( 0.77 -
4.91 )
3.05
13.41
( 0.77 -
4.91 )
3.05
13.41
( 0.77 -
4.91 )
3.05
13.37
( 0.77 -
4.90 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.03
13.29
( 0.77 -
4.88 )
3.05
3 05
13.37
3 3
( 0.77 -
4.90 )
3.05
13.37
( 0.77 -
4.90 )
3.05
13.37
( 0.77 -
4.90 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.03
13.29
( 0.77 -
4.88 )
3.02
13.25
( 0.77 -
4.87 )
3.05
13.37
( 0.77 -
4.90 )
3.05
13.37
( 0.77 -
4.90 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.02
13.27
( 0.77 -
4.88 )
3.02
13.25
( 0.77 -
4.87 )
3.05
13.37
( 0.77 -
4.90 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.02
13.25
( 0.77 -
4.87 )
3.02
13.25
( 0.77 -
4.87 )
3.03
13.29
( 0.77 -
4.88 )
Power
factor
(%)
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

Hide quick links: