Mitsubishi Electric MXZ-2D33VA Service Manual page 270

Hide thumbs Also See for MXZ-2D33VA:
Table of Contents

Advertisement

MXZ-5D102VA COOLING
Indoor units
combination
Unit A
22+25+25
2.20
22+25+35
2.09
22+25+42
1.98
22+25+50
1.88
22+25+60
1.77
22+25+71
1.64
22+35+35
1.94
22+35+42
1.87
22+35+50
1.77
22+35+60
1.65
22+35+71
1.55
22+42+42
1.78
22+42+50
1.70
22+42+60
1.60
22+42+71
1.50
22+50+50
1.60
22+50+60
1.52
22+50+71
1.43
22+60+60
1.44
22+60+71
1.35
22+71+71
1.26
25+25+25
2.50
25+25+35
2.32
25+25+42
2.20
25+25+50
2.10
25+25+60
1.98
25+25+71
1.84
25+35+35
2.16
25+35+50
1.98
25+35+60
1.85
25+35+71
1.74
25+42+42
2.00
25+42+50
1.88
25+42+60
1.77
25+42+71
1.67
25+50+50
1.80
25+50+60
1.70
25+50+71
1.59
25+60+60
1.60
25+60+71
1.51
25+71+71
1.41
Cooling capacity (kW)
Unit B
Unit C
Unit D
2.50
2.50
-
2.38
3.33
-
2.25
3.78
-
2.14
4.28
-
2.01
4.82
-
1.86
5.29
-
3.08
3.08
-
2.97
3.56
-
2.81
4.02
-
2.63
4.51
-
2.46
4.99
-
3.41
3.41
-
3.24
3.86
-
3.05
4.35
-
2.86
4.84
-
3.65
3.65
-
3.45
4.14
-
3.25
4.62
-
3.93
3.93
-
3.69
4.36
-
4.07
4.07
-
2.50
2.50
-
2.32
3.25
-
2.20
3.70
-
2.10
4.20
-
1.98
4.75
-
1.84
5.22
-
3.02
3.02
-
2.77
3.95
-
2.60
4.45
-
2.43
4.93
-
3.35
3.35
-
3.16
3.76
-
2.98
4.25
-
2.80
4.73
-
3.60
3.60
-
3.41
4.09
-
3.18
4.52
-
3.85
3.85
-
3.62
4.28
-
4.00
4.00
-
Unit E
Total
7.20
-
(2.90-8.70)
7.80
-
(2.90-9.10)
8.00
-
(2.90-9.20)
8.30
-
(2.90-9.30)
8.60
-
(2.90-9.40)
8.80
-
(2.90-9.70)
8.10
-
(2.90-9.20)
8.40
-
(2.90-9.30)
8.60
-
(2.90-9.40)
8.80
-
(2.90-9.70)
9.00
-
(2.90-10.00)
8.60
-
(2.90-9.40)
8.80
-
(2.90-9.60)
9.00
-
(2.90-9.90)
9.20
-
(2.90-10.20)
8.90
-
(2.90-9.80)
9.10
-
(2.90-10.10)
9.30
-
(2.90-10.50)
9.30
-
(2.90-10.50)
9.40
-
(2.90-10.80)
9.40
-
(2.90-10.80)
7.50
-
(2.90-9.00)
7.90
-
(2.90-9.10)
8.10
-
(2.90-9.20)
8.40
-
(2.90-9.30)
8.70
-
(2.90-9.50)
8.90
-
(2.90-9.80)
8.20
-
(2.90-9.30)
8.70
-
(2.90-9.50)
8.90
-
(2.90-9.80)
9.10
-
(2.90-10.10)
8.70
-
(2.90-9.50)
8.80
-
(2.90-9.70)
9.00
-
(2.90-9.90)
9.20
-
(2.90-10.40)
9.00
-
(2.90-9.90)
9.20
-
(2.90-10.20)
9.30
-
(2.90-10.70)
9.30
-
(2.90-10.60)
9.40
-
(2.90-10.80)
9.40
-
(2.90-10.80)
94/362
Outdoor unit
Current
power consumption(kW)
(A)
2.007
8.81
(0.690-2.810)
2.226
9.78
(0.700-3.015)
2.293
10.07
(0.700-3.010)
2.381
10.46
(0.710-3.005)
2.471
10.85
(0.720-3.010)
2.566
11.27
(0.700-3.050)
2.350
10.32
(0.710-3.020)
2.416
10.61
(0.710-3.015)
2.501
10.98
(0.720-3.020)
2.576
11.31
(0.700-3.055)
2.655
11.66
(0.690-3.115)
2.480
10.89
(0.720-3.015)
2.554
11.22
(0.710-3.045)
2.629
11.55
(0.690-3.080)
2.653
11.65
(0.680-3.195)
2.628
11.54
(0.700-3.070)
2.655
11.66
(0.680-3.155)
2.663
11.70
(0.670-3.285)
2.650
11.64
(0.670-3.270)
2.650
11.64
(0.660-3.360)
2.630
11.55
(0.660-3.350)
2.140
9.40
(0.690-3.010)
2.263
9.94
(0.700-3.015)
2.330
10.23
(0.710-3.010)
2.418
10.62
(0.720-3.005)
2.502
10.99
(0.710-3.025)
2.598
11.41
(0.700-3.065)
2.387
10.48
(0.710-3.025)
2.532
11.12
(0.710-3.035)
2.607
11.45
(0.700-3.070)
2.663
11.70
(0.680-3.155)
2.512
11.03
(0.710-3.030)
2.586
11.36
(0.700-3.055)
2.653
11.65
(0.690-3.105)
2.660
11.68
(0.680-3.230)
2.660
11.68
(0.690-3.085)
2.663
11.70
(0.680-3.195)
2.670
11.73
(0.670-3.320)
2.658
11.67
(0.670-3.310)
2.650
11.64
(0.660-3.360)
2.630
11.55
(0.660-3.350)
Power
factor(%)
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents