Mitsubishi Electric MXZ-2D33VA Service Manual page 317

Hide thumbs Also See for MXZ-2D33VA:
Table of Contents

Advertisement

MXZ-5D102VA HEATING
Indoor units
combination
Unit A
15+18+60+71
0.82
15+20+20+20
1.70
15+20+20+22
1.61
15+20+20+25
1.56
15+20+20+35
1.50
15+20+20+42
1.32
15+20+20+50
1.15
15+20+20+60
1.11
15+20+20+71
1.12
15+20+22+22
1.49
15+20+22+25
1.45
15+20+22+35
1.40
15+20+22+42
1.24
15+20+22+50
1.10
15+20+22+60
1.06
15+20+22+71
1.08
15+20+25+25
1.41
15+20+25+35
1.36
15+20+25+50
1.08
15+20+25+60
1.05
15+20+25+71
1.06
15+20+35+35
1.33
15+20+35+42
1.20
15+20+35+50
1.07
15+20+35+60
1.03
15+20+35+71
1.04
1.09
15+20+42+42
15+20+42+50
0.98
15+20+42+60
0.96
15+20+42+71
0.96
15+20+50+50
0.89
15+20+50+60
0.87
15+20+50+71
0.87
15+20+60+60
0.84
0.84
15+20+60+71
15+22+22+22
1.39
15+22+22+25
1.36
1.31
15+22+22+35
15+22+22+42
1.18
15+22+22+50
1.05
1.02
15+22+22+60
Heatling capacity (kW)
Unit B
Unit C
Unit D
1.59
3.80
3.80
2.20
2.20
2.20
2.08
2.08
3.12
2.02
2.02
3.30
1.94
1.94
3.52
1.70
1.70
4.18
1.49
1.49
4.87
1.43
1.43
5.14
1.45
1.45
5.19
1.93
2.89
2.89
1.87
2.81
3.07
1.81
2.71
3.29
1.61
2.41
3.94
1.42
2.13
4.65
1.37
2.05
4.92
1.40
2.10
5.02
1.82
2.98
2.98
1.76
2.88
3.20
1.39
2.28
4.56
1.36
2.22
4.87
1.37
2.24
4.92
1.72
3.13
3.13
1.55
2.83
3.82
1.38
2.52
4.53
1.34
2.43
4.80
1.35
2.46
4.85
1.41
3.45
3.45
1.27
3.11
4.15
1.24
3.05
4.46
1.24
3.05
4.46
1.15
3.78
3.78
1.12
3.68
4.03
1.12
3.68
4.03
1.08
3.89
3.89
1.08
3.89
3.89
2.70
2.70
2.70
2.63
2.63
2.87
2.55
2.55
3.09
2.29
2.29
3.74
2.04
2.04
4.46
1.98
1.98
4.73
Unit E
Total
10.00
-
(3.40-12.60)
8.30
-
(3.40-12.00)
8.90
-
(3.40-12.20)
8.90
-
(3.40-12.20)
8.90
-
(3.40-12.20)
8.90
-
(3.40-12.20)
9.00
-
(3.40-12.20)
9.10
-
(3.40-12.20)
9.20
-
(3.40-12.20)
9.20
-
(3.40-12.40)
9.20
-
(3.40-12.40)
9.20
-
(3.40-12.40)
9.20
-
(3.40-12.40)
9.30
-
(3.40-12.40)
9.40
-
(3.40-12.40)
9.60
-
(3.40-12.40)
9.20
-
(3.40-12.40)
9.20
-
(3.40-12.40)
9.30
-
(3.40-12.40)
9.50
-
(3.40-12.40)
9.60
-
(3.40-12.40)
9.30
-
(3.40-12.40)
9.40
-
(3.40-12.40)
9.50
-
(3.40-12.40)
9.60
-
(3.40-12.40)
9.70
-
(3.40-12.40)
9.40
-
(3.40-12.40)
9.50
-
(3.40-12.40)
9.70
-
(3.40-12.40)
9.70
-
(3.40-12.40)
9.60
-
(3.40-12.40)
9.70
-
(3.40-12.40)
9.70
-
(3.40-12.40)
9.70
-
(3.40-12.40)
9.70
-
(3.40-12.40)
9.50
-
(3.40-12.60)
9.50
-
(3.40-12.60)
9.50
-
(3.40-12.60)
9.50
-
(3.40-12.60)
9.60
-
(3.40-12.60)
9.70
-
(3.40-12.60)
141/362
Outdoor unit
Current
power consumption(kW)
(A)
2.742
12.04
(0.640-3.870)
2.062
9.06
(0.790-3.990)
2.192
9.63
(0.740-4.035)
2.192
9.63
(0.740-4.100)
2.192
9.63
(0.740-3.915)
2.192
9.63
(0.740-3.905)
2.232
9.80
(0.740-3.900)
2.302
10.11
(0.740-3.890)
2.380
10.45
(0.740-3.880)
2.322
10.20
(0.690-4.080)
2.322
10.20
(0.690-4.055)
2.322
10.20
(0.690-3.915)
2.322
10.20
(0.690-3.900)
2.378
10.44
(0.690-3.900)
2.448
10.75
(0.690-3.890)
2.526
11.09
(0.690-3.880)
2.322
10.20
(0.690-3.990)
2.322
10.20
(0.690-3.910)
2.402
10.55
(0.690-3.900)
2.472
10.86
(0.690-3.890)
2.550
11.20
(0.690-3.880)
2.362
10.37
(0.690-3.900)
2.418
10.62
(0.690-3.900)
2.482
10.90
(0.690-3.900)
2.552
11.21
(0.690-3.890)
2.622
11.52
(0.690-3.880)
2.474
10.87
(0.690-3.900)
2.538
11.15
(0.690-3.900)
2.608
11.45
(0.690-3.890)
2.622
11.52
(0.690-3.880)
2.602
11.43
(0.690-3.900)
2.632
11.56
(0.690-3.890)
2.622
11.52
(0.690-3.880)
2.622
11.52
(0.690-3.880)
2.612
11.47
(0.690-3.870)
2.452
10.77
(0.640-4.080)
2.452
10.77
(0.640-4.010)
2.452
10.77
(0.640-3.910)
2.460
10.80
(0.640-3.900)
2.524
11.08
(0.640-3.900)
2.594
11.39
(0.640-3.890)
Power
factor(%)
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents