Mitsubishi Electric MXZ-2D33VA Service Manual page 473

Hide thumbs Also See for MXZ-2D33VA:
Table of Contents

Advertisement

MXZ-6D122VA HEATING
Indoor units
combination
Unit A
15+15+22+35+60
1.37
15+15+22+35+71
1.27
15+15+22+42+42
1.48
15+15+22+42+50
1.40
15+15+22+42+60
1.31
15+15+22+42+71
1.22
15+15+22+50+50
1.32
15+15+22+50+60
1.24
15+15+22+50+71
1.16
15+15+22+60+60
1.17
15+15+25+25+25
1.91
15+15+25+25+35
1.75
15+15+25+25+42
1.65
15+15+25+25+50
1.55
15+15+25+25+60
1.44
15+15+25+25+71
1.33
15+15+25+35+35
1.61
15+15+25+35+42
5
5
5 35
1.52
5
15+15+25+35+50
1.44
15+15+25+35+60
1.34
15+15+25+35+71
1.25
15+15+25+42+42
1.45
15+15+25+42+50
1.37
15+15+25+42+60
1.28
15+15+25+42+71
1.20
15+15+25+50+50
1.30
15+15+25+50+60
1.22
15+15+25+50+71
1.14
15+15+25+60+60
1.15
15+15+35+35+35
1.49
15+15+35+35+42
1.42
15+15+35+35+50
1.34
15+15+35+35+60
1.26
15+15+35+35+71
1.18
15+15+35+42+42
1.35
15+15+35+42+50
1.28
Heating Capacity (kW)
Unit B
Unit C
Unit D
Unit E
1.37
2.01
3.19
5.47
1.27
1.87
2.97
6.02
1.48
2.17
4.14
4.14
1.40
2.05
3.91
4.65
1.31
1.91
3.65
5.22
1.22
1.79
3.41
5.77
1.32
1.94
4.41
4.41
1.24
1.82
4.14
4.96
1.16
1.70
3.87
5.50
1.17
1.71
4.67
4.67
1.91
3.19
3.19
3.19
1.75
2.91
2.91
4.08
1.65
2.75
2.75
4.61
1.55
2.58
2.58
5.15
1.44
2.39
2.39
5.74
1.33
2.22
2.22
6.30
1.61
2.68
3.75
3.75
1.52
5
2.54
5
3 55
3.55
4.26
1.44
2.39
3.35
4.79
1.34
2.23
3.13
5.36
1.25
2.08
2.91
5.91
1.45
2.41
4.05
4.05
1.37
2.28
3.83
4.56
1.28
2.13
3.58
5.12
1.20
1.99
3.35
5.66
1.30
2.16
4.32
4.32
1.22
2.03
4.06
4.87
1.14
1.90
3.81
5.41
1.15
1.91
4.59
4.59
1.49
3.47
3.47
3.47
1.42
3.30
3.30
3.96
1.34
3.13
3.13
4.47
1.26
2.93
2.93
5.03
1.18
2.74
2.74
5.56
1.35
3.15
3.78
3.78
1.28
2.99
3.58
4.27
Unit F
Total
-
13.41
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
6
-
13.39
3 39
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.39
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
-
13.41
( 3.50 -
15.60 )
-
13.40
( 3.50 -
15.60 )
297/362
Outdoor unit
power consumpution
Current (A)
(kW)
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.03
13.29
( 0.77 -
4.88 )
3.02
13.25
( 0.77 -
4.87 )
3.02
13.25
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.05
13.41
( 0.77 -
4.91 )
3.05
13.41
( 0.77 -
4.91 )
3.05
13.37
( 0.77 -
4.90 )
3.04
13.33
( 0.77 -
4.89 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.05
13.41
( 0.77 -
4.91 )
3.05
3 05
13.37
3 3
( 0.77 -
4.90 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.03
13.29
( 0.77 -
4.88 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.02
13.27
( 0.77 -
4.88 )
3.02
13.25
( 0.77 -
4.87 )
3.02
13.25
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.06
13.45
( 0.77 -
4.87 )
3.05
13.37
( 0.77 -
4.90 )
3.05
13.37
( 0.77 -
4.90 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
3.03
13.29
( 0.77 -
4.88 )
3.04
13.33
( 0.77 -
4.89 )
3.03
13.29
( 0.77 -
4.88 )
Power
factor
(%)
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents