MXZ-4D72VA HEATING
Indoor units
combination
Unit A
15+22+22+60
0.86
15+22+25+25
1.14
15+22+25+35
1.11
15+22+25+42
1.00
15+22+25+50
0.88
15+22+25+60
0.84
15+22+35+35
1.07
15+22+35+42
0.97
15+22+35+50
0.86
0.88
15+22+42+42
15+25+25+25
1.12
15+25+25+35
1.08
0.97
15+25+25+42
15+25+25+50
0.87
15+25+25+60
0.83
15+25+35+35
1.05
15+25+35+42
0.95
15+25+35+50
0.84
15+25+42+42
0.87
15+35+35+35
1.02
18+18+18+18
2.15
18+18+18+20
2.35
18+18+18+22
2.15
2.10
18+18+18+25
18+18+18+35
2.04
18+18+18+42
1.85
18+18+18+50
1.66
18+18+18+60
1.59
18+18+20+20
2.58
18+18+20+22
2.35
18+18+20+25
2.29
18+18+20+35
2.22
18+18+20+42
2.00
18+18+20+50
1.77
18+18+20+60
1.70
18+18+22+22
2.15
18+18+22+25
2.10
2.04
18+18+22+35
18+18+22+42
1.85
18+18+22+50
1.66
18+18+22+60
1.59
Heatling capacity (kW)
Unit B
Unit C
Unit D
1.67
1.67
4.00
2.22
2.42
2.42
2.15
2.34
2.60
1.93
2.11
3.16
1.71
1.87
3.74
1.64
1.79
3.93
2.08
2.52
2.52
1.88
2.28
3.08
1.67
2.02
3.64
1.71
2.80
2.80
2.36
2.36
2.36
2.29
2.29
2.54
2.06
2.06
3.10
1.83
1.83
3.67
1.76
1.76
3.86
2.22
2.47
2.47
2.01
2.23
3.01
1.79
1.99
3.58
1.83
2.75
2.75
2.39
2.39
2.39
2.15
2.15
2.15
2.35
2.35
1.56
2.15
2.15
2.15
2.10
2.10
2.29
2.04
2.04
2.47
1.85
1.85
3.04
1.66
1.66
3.62
1.59
1.59
3.82
2.58
1.72
1.72
2.35
1.56
2.35
2.29
1.53
2.50
2.22
1.48
2.69
2.00
1.33
3.27
1.77
1.18
3.87
1.70
1.13
4.07
2.15
2.15
2.15
2.10
2.10
2.29
2.04
2.04
2.47
1.85
1.85
3.04
1.66
1.66
3.62
1.59
1.59
3.82
Unit E
Total
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.20
-
(3.40-10.40)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
8.60
-
(3.40-10.70)
53/362
Outdoor unit
Current
power consumption(kW)
(A)
1.972
8.66
(0.670-2.860)
2.002
8.79
(0.670-2.870)
1.992
8.75
(0.670-2.880)
1.992
8.75
(0.670-2.880)
1.982
8.70
(0.670-2.870)
1.972
8.66
(0.670-2.860)
1.982
8.70
(0.670-2.870)
1.982
8.70
(0.670-2.870)
1.972
8.66
(0.670-2.860)
1.982
8.70
(0.670-2.870)
2.002
8.79
(0.670-2.890)
1.992
8.75
(0.670-2.880)
1.992
8.75
(0.670-2.880)
1.982
8.70
(0.670-2.870)
1.972
8.66
(0.670-2.860)
1.982
8.70
(0.670-2.870)
1.982
8.70
(0.670-2.870)
1.972
8.66
(0.670-2.860)
1.982
8.70
(0.670-2.870)
1.972
8.66
(0.670-2.860)
2.172
9.54
(0.600-2.790)
2.272
9.98
(0.670-2.935)
2.172
9.54
(0.600-2.790)
2.172
9.54
(0.600-2.790)
2.162
9.49
(0.600-2.960)
2.162
9.49
(0.600-2.960)
2.152
9.45
(0.600-2.950)
2.142
9.41
(0.600-2.940)
2.372
10.42
(0.740-3.080)
2.272
9.98
(0.670-2.935)
2.272
9.98
(0.670-2.960)
2.262
9.93
(0.670-3.105)
2.262
9.93
(0.670-3.105)
2.252
9.89
(0.670-3.095)
2.242
9.85
(0.670-3.085)
2.172
9.54
(0.600-2.790)
2.172
9.54
(0.600-2.860)
2.162
9.49
(0.600-2.960)
2.162
9.49
(0.600-2.960)
2.152
9.45
(0.600-2.950)
2.142
9.41
(0.600-2.940)
Power
factor(%)
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99
99