2.0 Preparing to Install the MR-2602 Fire Panel

2.1 Unpacking the MR-2602

The basic MR-2602 package includes the following components:
•Cabinet with hinged door
•Display and control plate c/w display and control printed circuit board.
•Zone label insert
•Battery compartment dead front plate
•Main control PCB
•Transformer
•Installation manual
•Hardware pack
• Door keys (taped to outside of cabinet)
All components described above are factory assembled into the enclosure.

2.2 Optional Accessories

Model Number
MR-2605-R3
Relay module
MR-2806
Dual line dialer
MR-2644
Programmer
Remote trouble
MR-2605-T
indicator
Remote trouble
MR-2605-AT
indicator and alarm
indicator
EOL supervision
MR-2605-SR
relay
MRD-EOL4.7K
EOLR
MRD-MP400
EOLR plate
-- 2 × NAC EOL resistors (4.7 K, 5%, ½ W)
-- 2 × Zone EOL resistors (4.7 K, 5%, ½ W)
-- 1 × Battery jumper wire
-- 1 × EGND terminal ring
-- 1 × EGND KEP nut
Name
Provides 3 relays that are jumper programmable to activate on
common 'alarm', 'supervisory' or 'trouble'. Mounts inside the enclosure
and plugs into the main board.
Communicates all alarms, supervisory and trouble conditions to a
Central Station using Contact ID, SIA or 10/20 BPS communication
formats. Programmable using the MR-2644 handheld programmer.
Mounts inside the enclosure and connects to the main panel using a
supplied 4-wire cable with connector.
Handheld programmer for the MR-2806 DACT.
Single gang plate complete with common trouble buzzer, trouble
visual indicator, 'AC on' visual indicator and a trouble silence / lamp
test switch. Mounts remotely to a single gang electrical box and is
connected to the main panel via the 4-wire 'secur-bus'.
Two gang plate complete with common trouble buzzer, trouble visual
indicator, 'AC on' visual indicator and a trouble silence / lamp test
switch and red zone alarm visual indicators and
supervisory indictors. Mounts to a standard 2 gang electrical box and
is connected to the panel via the 4-wire 'secur-bus'.
Supervises the extended power wiring typically used for installations
that employ 4-wire smoke detectors. Mounts in the field.
End-of-Line resistor for NAC and Initiating circuits. Mounts in the field.
Single gang plate with EOL resistor. Mounts to a single gang electrical
backbox.