To Configure The E1 Daughter Card - Multitech CommPlete RAS96 User Manual

Rascard - e1
Hide thumbs Also See for CommPlete RAS96:
Table of Contents

Advertisement

RAS96 RASCard User Guide

To Configure the E1 Daughter Card

1.
2.
3.
4.
5.
48
Turn on power to the segment containing the E1 Card to be configured.
Log in to the controller as supervisor, supervisor and type the command E1status
1b (5b, 9b, or 13b) for E1-1 at the A:# prompt. The E1 Card Status screen is
displayed.
If the line settings do not match the line settings of your E1 line, type the command
E1setup 1b (5b, 9b, or 13b) at the A:# prompt.
The E1 setup will take you through a series of menus where you will enter the
information that was gathered in the Installation Overview.
Factory Defaults:
Framing:
Line Coding:
Signaling Options:
When you save the changes at the end, the E1 parameters are then sent to the E1
card for configuration.
CRC4
HDB3
R2 digital
CommPlete Communications Server