This furnace has provisions allowing for electrical and gas line con-
nections through either side panel. In horizontal applications the
connections can be made either through the "top" or "bottom" of
the furnace.
D
P
RAIN
AN
A drain pan must be provided if the furnace is installed above a
conditioned area. The drain pan must cover the entire area under
the furnace (and air conditioning coil if applicable).
F
P
REEZE
ROTECTION
Refer to Horizontal Applications and Conditions - Drain Trap and
Lines.
F
S
URNACE
USPENSION
If the furnace is installed in a crawl space it must be suspended
from the floor joist or supported by a concrete pad. Never install
the furnace on the ground or allow it to be exposed to water. Refer
to Location Requirements and Considerations - Furnace Suspen-
sion for further details.
P
G
/H
ROPANE
AS
IGH
P
 
 
OSSIBLE
PROPERTY
DAMAGE
 
 
 
 
OCCUR
IF
THE
CORRECT
CONVERSION
 
 
 
 
APPROPRIATE
KITS
MUST
BE
APPLIED
 
. A
 
FURNACE
OPERATION
LL
CONVERSIONS
 
 
 
QUALIFIED
INSTALLER
OR
SERVICE
This furnace is shipped from the factory configured for natural gas
at standard altitude. Propane gas installations require an orifice
and orifice change to compensate for the energy content differ-
ence between natural and propane gas.
High altitude installations may require both a pressure switch and
an orifice/spring change. These changes are necessary to com-
pensate for the natural reduction in the density of both the gas fuel
and the combustion air at higher altitude.
For installations above 7000 feet, please refer to your distributor
for required kit(s).
Gas
A lt itude
Kit
Orif ice
Natural
None
0-7000
1
LPM -05*
P ropane
2
LPM -06*
1
LPM -05* supports White-Rodgers 2-stage valve only
2
LPM -06* supports both Honeywell and White-Ro dgers 2-stage valves
N O T E: In Canada, gas furnaces are only certified to 4500 feet.
A
IGH
LTITUDE
G
L
C
AS
INE
ONNECTIONS
A
I
LTITUDE
NSTALLATIONS
WARNING
 
 
 
 
PERSONAL
INJURY
OR
DEATH
MAY
 
 
 
 
KITS
ARE
NOT
INSTALLED
 
 
 
 
 
TO
ENSURE
SAFE
AND
PROPER
 
 
 
MUST
BE
PERFORMED
 
.
AGENCY
M anifo ld P res sure
H igh
Lo w
Sta ge
S tage
#43
3.5" w.c.
1 .9" w.c.
#55
1 0.0" w.c.
6.0" w.c.
I
NSTALLATIONS
Contact the distributor for a tabular listing of appropriate
manufacturer's kits for propane gas and/or high altitude installa-
tions. The indicated kits must be used to insure safe and proper
furnace operation. All conversions must be performed by a quali-
fied installer, or service agency.
V
/F
ENT
LUE
F
 
AILURE
TO
 
 
INJURY
OR
DEATH
 
 
GIVEN
IN
THIS
U
 
PON
COMPLETION
 
INSPECT
THE
 
FURNACE
TO
 
SYSTEM
CAN
 
EXPOSURE
TO
A condensing gas furnace achieves its high level of efficiency by
extracting almost all of the heat from the products of combustion
and cooling them to the point where condensation takes place.
Because of the relatively low flue gas temperature and water con-
densation requirements, PVC pipe is used as venting material.
This furnace must not be connected to Type B, BW, or L vent or
 
vent connector, and must not be vented into any portion of a fac-
. T
 
HE
tory built or masonry chimney except when used as a pathway for
 
PVC as described later in this section. Never common vent this
 
 
 
BY
A
appliance with another appliance or use a vent which is used by a
solid fuel appliance. Do not use commercially available "no hub
connectors" other than those shipped with this product.
It is the responsibility of the installer to follow the manufacturers'
recommendations and to verify that all vent/flue piping and connec-
tors are compatible with furnace flue products. Additionally, it is
the responsibility of the installer to ensure that all piping and con-
nections possess adequate structural integrity and support to pre-
vent flue pipe separation, shifting, or sagging during furnace opera-
tion.
D
C
UAL
ERTIFICATION
This furnace is dual certified and may be installed as a non-direct
vent (single pipe) or direct vent (dual pipe) appliance. A non-direct
P res sure
vent installation requires only a vent/flue pipe, while a direct vent
Switch
installation requires both a vent/flue pipe and a combustion air
C ha nge
intake pipe. Refer to the appropriate section for details concerning
No ne
piping size, length, number of elbows, furnace connections, and
terminations.
No ne
12
P
& C
IPE
OMBUSTION
WARNING
 
 
 
 
FOLLOW
THESE
INSTRUCTIONS
. C
 
 
 
AREFULLY
READ
AND
FOLLOW
 
.
SECTION
WARNING
 
 
 
 
OF
THE
FURNACE
INSTALLATION
 
 
 
 
 
ENTIRE
FLUE
SYSTEM
BOTH
INSIDE
 
 
 
 
 
ASSURE
IT
IS
PROPERLY
SEALED
 
 
 
 
RESULT
IN
SERIOUS
PERSONAL
 
 
 
FLUE
PRODUCTS
INCLUDING
: N
-D
/D
ON
IRECT
A
P
IR
IPE
 
 
 
 
CAN
RESULT
IN
BODILY
 
 
 
ALL
INSTRUCTIONS
 
CAREFULLY
 
 
 
 
 
AND
OUTSIDE
OF
THE
. L
 
 
 
 
EAKS
IN
THE
FLUE
 
 
 
 
 
 
INJURY
OR
DEATH
DUE
TO
 
.
CARBON
MONOXIDE
V
IRECT
ENT