delay period prior to stepping up can be set at either a fixed 5
minute time delay or a load based variable time between 1 and 12
minutes (AUTO mode). If the AUTOmode is selected, the control
averages the cycle times of the previous three cycles and uses
the average to determine the time to transition from low stage to
high stage.
To use a single-stage thermostat, turn off power to the furnace,
move the thermostat selection DIP switch to the OFF position.
Set the desired transition time by setting the transition delay DIP
switch to the desired ON/OFF position. Turn power back on. Refer
to the following figure.
OFF
Heat OFF Delay
DIP Switches
3
4
S1
24 V
D
W
OLT
EHUMIDISTAT
The optional usage of a dehumidistat allows the furnace's circula-
tor blower to operate at a slightly lower speed (82% of desired
speed) during a combined thermostat call for cooling and dehumi-
distat call for dehumidification. This can be done through an inde-
pendent dehumidistat or through a thermostat's DEHUM terminal
(if available). This lower blower speed enhances dehumidification
of the conditioned air as it passes through the AC coil. For proper
function, a dehumidistat applied to this furnace must operate on
24 VAC and utilize a switch which opens on humidity rise.
To install/connect a dehumidistat:
1. Turn OFF power to furnace.
2. Secure the dehumidistat neutral wire (typically the white
lead) to the terminal marked "DEHUM" on the furnace
integrated control module.
3. Secure the dehumidistat hot wire (typically the black lead)
to the terminal marked "R" on the furnace integrated control
module.
4. Secure the dehumidistat ground wire (typically the green
lead) to the ground screw on the furnace junction box.
NOTE: Ground wire may not be present on all
dehumidistats.
5. Turn ON power to furnace.
To enable the dehumidify function on the integrated control mod-
ule, set the dehumidification ENABLE dipswitch from OFF to ON.
Once the switch is set, the dehumidify function is enabled during a
combination call for cooling (T-Stat) and dehumidification (DEHUM-
Stat).
OFF
ON
9
10
S5
ON
Move to the ON position
to select two-stage
thermostat or OFF to
select single stage
thermostat
Thermostat
Stage Delay
Move to the ON position
to select Auto transition
delay or OFF for 5 minute
transition delay

IRING

DEHUM
Move to the ON position
to enable dehumidification
Unused
E
LECTRICAL
F
F
A
OSSIL
UEL
PPLICATIONS
This furnace can be used in conjunction with a heat pump in a
fossil fuel application. A fossil fuel application refers to a combined
gas furnace and heat pump installation which uses an outdoor
temperature sensor to determine the most cost efficient means of
heating (heat pump or gas furnace).
A heat pump thermostat with three stages of heat is required to
properly use a two-stage furnace in conjunction with a heat pump.
Refer to the fossil fuel kit installation instructions for additional
thermostat requirements.
Strictly follow the wiring guidelines in the fossil fuel kit installation
instructions. All furnace connections must be made to the furnace
two-stage integrated control module and the "FURNACE" terminal
strip on the fossil fuel control board.
115 V
L
C
OLT
INE
ONNECTION OF
E
A
C
LECTRONIC
IR
LEANER
HIGH VOLTAGE !
T
 
 
 
O
AVOID
PERSONAL
INJURY
 
ELECTRICAL
SHOCK
DISCONNECT
 
 
 
BEFORE
SERVICING
OR
CHANGING
.
WIRING
The furnace integrated control module is equipped with line voltage
accessory terminals for controlling power to an optional field-sup-
plied humidifier and/or electronic air cleaner.
The accessory load specifications are as follows:
Humidifier
Electronic Air Cleaner
Turn OFF power to the furnace before installing any accessories.
Follow the humidifier or air cleaner manufacturers' instructions for
locating, mounting, grounding, and controlling these accessories.
Accessory wiring connections are to be made through the 1/4"
quick connect terminals provided on the furnace integrated control
module. The humidifier and electronic air cleaner hot terminals are
identified as HUM and EAC. The humidifier and electronic air
cleaner neutral terminals are identified as NEUTRAL. All field wir-
ing must conform to applicable codes. Connections should be
made as shown.
29
C
ONNECTIONS
A
(H
CCESSORIES
UMIDIFIER AND
)
WARNING
 
 
 
 
 
OR
DEATH
DUE
TO
 
 
 
ELECTRICAL
POWER
 
 
 
ANY
ELECTRICAL
1.0 Amp maximum at 120 VAC
1.0 Amp maximum at 120 VAC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents