Goodman GMVC950704CX Installation Instructions Manual page 16

Hide thumbs Also See for GMVC950704CX:
Table of Contents

Advertisement

V
/F
P
ENT
LUE
IPE
8. Upflow and Counterflow units.
For horizontal installations, externally secure the field-
supplied vent/flue pipe directly to the vent/flue coupling using
a PVC or ABS coupling or elbow.
A
C
A
LTERNATE
OMBUSTION
IR
The alternate combustion air intake location consists of a large,
unobstructed hole (alternate vent connection is aligned with the
Induced Draft Blower). To use the alternate combustion air intake
location, refer to the following steps, and the "Alternate Combus-
tion Air Intake Location" figure.
1. Remove and save the four screws securing the combustion
air intake coupling to the basepan. Remove an additional
three screws securing the furnace's internal combustion
air intake pipe to the blower deck.
2. Remove the combustion air intake pipe from the furnace
and cut the pipe at the basepan coupling. Save the basepan
coupling and gasket from the blower deck coupling for use
in the alternate location. Discard the remaining pipe.
3
REMOVE
PIPE
& C
OMBUSTION
I
L
NTAKE
OCATION
5
REMOVE
AND RELOCATE
2
DETACH RUBBER
ELBOW FROM
ID BLOWER AND
VENT/FLUE
PIPE
5
ADDITIONAL PLUG
FROM DRAIN KIT
7
EXTERNALLY
MOUNT
RUBBER ELBOW
6
SECURE TO
ID BLOWER WITH
RUBBER COUPLING
AND HOSE
CLAMPS
A
P
IR
IPE
3. Remove plastic plug from alternate combustion air intake
location. Relocate and install plug in standard air intake
location (basepan). Plug the remaining hole in the blower
deck with the plastic plug included in the drain kit bag.
4. With the gasket facing the cabinet side panel, and the
flange's flat spot facing forward, secure the combustion air
intake coupling to the cabinet using the screws removed in
step 1 or with field-supplied 3/8" #8 self -drilling screws.
B
 
 
 
 
E
SURE
NOT
TO
DAMAGE
 
WHEN
REINSTALLING
5. For non-direct vent installations installed horizontally, a
minimum of one 90° elbow should be installed on the
combustion air intake coupling to guard against inadvertent
blockage. No elbow is required on the alternate combustion
air intake of upright installations, however, a minimum
clearance of 2 inches is required to assure proper air supply.
6. For direct vent installations, secure field-supplied
combustion air intake pipe directly to the air intake coupling.
NOTE: A PVC coupling or elbow is required on counterflow
units.
6
SECURE TO
ID BLOWER WITH
RUBBER COUPLING
AND HOSE
CLAMPS
16
CAUTION
 
 
 
 
INTERNAL
WIRING
OR
OTHER
 
 
 
.
COUPLING
AND
SCREWS
3
REMOVE
PIPE
REMOVE
3 SCREWS
REMOVE
AND RELOCATE
DETATCH RUBBER
ELBOW FROM
ID BLOWER AND
VENT/FLUE
6
SECURE TO
CABINET WITH
SCREWS
 
 
COMPONENTS
1
5
2
PIPE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents