Final Check - BuckMaster 94NC Preparations, Installation, Operation, Maintenance, Safety

Non-catalytic unit
Hide thumbs Also See for 94NC:
Table of Contents

Advertisement

1. Recheck specified clearances.
2. Remove all foreign material from firebox area.
3. Open primary air control. Primary Air Controls: The primary air intake control is located
at right bottom side of hearth. It is operated by moving the handle out to open (to allow air
into the firebox) or in to control or close off the firebox.
4. Plug power cord into a 115V AC outlet to see if motor and blower works. Do not run power
cord under unit or in high traffic areas.
5. Place crumpled pieces of newspaper in stove. Light it and close door. Ensure that
stove draws properly through primary draft.
6. Check for smoke leaks around door.
Open door and check for smoke escaping from front of the stove. Smoking usually
indicates a defective or poorly positioned chimney. Some chimneys with a marginal draft
can be preheated by lighting newspaper and holding it near open damper with a poker or
fire tong. Once chimney heats up, a proper draft can usually be obtained.
If review of Troubleshooting Guide does not reveal problem, contact your dealer for assistance.
The unit is painted with a specially formulated high temperature paint that cures during
the first two or three firings. You may notice a slight smoking effect and an odor of
burning paint when you build the first fire. This is normal and is not a cause for alarm. In
some cases, these fumes will activate a smoke alarm. Opening a window near unit will
allow these fumes to escape. DO NOT build a large, roaring fire until this curing
is complete or heater finish may be damaged.

FINAL CHECK

CAUTION
CAUTION
Page 18