Com Ports - Gemini 720is Product Manual

Imaging sonar
Table of Contents

Advertisement

Gemini Software Operation
Baud
Decode
Max
Age
Hz
String

5.3.3. COM Ports

The COM Ports enables two extra tabs called Serial Setup and Sonar Ports from
where all the serial communication (both connected to the PC and ports on the Gemini head)
are configured.
Serial setup
The Serial Setup tab controls the serial communication being inputted and exported by
the Gemini software.
COM Port
...
Mode
Sync
Decode
Max
Age
Document: 0703-SOM-00002, Issue: 1
The baud rate of the sensor connected to the port.
The decode definition to apply for the expected receive data on the port.
Set the time in seconds to generate an alarm if no data is received.
The age of the data, shows when the last good data was received (see
note below).
The incoming data rate
The incoming data string, check this against the chosen Decode if the
data indicator is red.
Note
The data age status indicator will show the status of each port. A grey indicator
means no data is present, red is for an incorrect data string, yellow indicates an
incomplete data string and green is for normal operation.
The COM port to use.
Open the settings dialog for configuring the port baud rate, data bits,
parity and flow control.
Can change between an ASCII or binary decode (ASCII is the default
and binary is only used for the Simrad EM3000).
The sync character used to frame the ASCII string.
The decode definition to apply for the expected receive data on the port.
Set the time in seconds to generate an alarm if no data is received.
The age of the data, shows when the last good data was received (see
note below).
48
Gemini 720is Imaging Sonar