Operation; Hot Plugging - ATEN Master View CS-88A User Manual

Aten technology kvm switch user manual
Hide thumbs Also See for Master View CS-88A:
Table of Contents

Advertisement

Operation

Hot Plugging

The Master View CS-88A supports hot plugging. Components can be removed
and added back into the installation by unplugging and replugging their cables
from their respective ports without the need to shut the switch down. For hot
plugging to work properly, the following procedures must be observed:
M Hot Plugging CPU Ports:
When hot plugging cables from the CPU ports:
1. The cable must be plugged back into the same port it was removed from.
2. The mouse cable must be plugged in before the keyboard cable.
3. After plugging the cable back in, you must perform a KVM Reset on the
First Stage unit (by pressing the Reset switch In).
M Hot Plugging Console Ports:
The unit supports hot plugging of the keyboard, monitor, and mouse. When
hot plugging the mouse from the Master View's console mouse port:
1. You may unplug the mouse and plug it back in again (to reset the mouse,
for example), as long as you use the same mouse.
2. If you plug in a different mouse, all the stations and all the computers on
the installation must be shut down for 10 seconds, then restarted. (Refer
back to the note describing the Power On sequence on p. 10, if
necessary.)
Note: If, after hot plugging (or at any other time), there is no response to
mouse and/or PS/2 keyboard input, simultaneously press and hold
Port Select buttons 1 and 2 on the First Stage unit for 3 seconds to
perform a PS/2 Keyboard and PS/2 Mouse reset.
CS-88A User Manual
2002-12-27
11

Advertisement

Table of Contents
loading

Table of Contents