IDEAL imax W45 Installation And Servicing Manual page 11

Hide thumbs Also See for imax W45:
Table of Contents

Advertisement

7
WALL MOUNTING TEMPLATE
Note. The template shows the positions for the
fixing holes. Care must be taken to ensure the
correct holes are drilled.
1. Tape template into the selected position.
2. Ensure squareness by hanging a plumbline.
3. Mark onto the wall
a. The 4 wall mounting plate screw
positions.
b. The boiler lower fixing position
c. The position of the flue duct. Mark the
centre of the hole as well as the
circumference.
4. Remove the template from the wall.
8
PREPARING THE WALL
IMPORTANT. Ensure that, during the cutting
operation, masonry falling outside of the building
does not cause damage or personal injury.
1. Cut the flue hole ensuring that the hole is
square to the wall. Both wall faces
immediately around the cut hole should be
flat.
2. Drill 4 holes with a 12mm (
and insert the plastic plugs provided, for the
wall mounting plate.
3. Mark off and drill the boiler lower fixing
position with a 12mm (
1
/
insert the plastic plug provided .
4. Fix the wall bracket into place with 4 M10x70
hex head coach screws provided.
-
Installation & Servicing
INSTALLATION
26
Vertical Offset From X mm
Y
X
1m
2m
Distance from flue centre line (Y) to outside wall surface.
For lengths greater than 4m, increase offset (X) by 26mm
for every additional 1m.
1
/
") masonry drill
2
") masonry drill,
2
Note: Horizontal flue runs must be inclined
at 1.5-3º to the horizontal to allow
condensate to drain back to the boiler.
52
78
104
3m
4m
DATUM 'X'
ima5430
11