Rating Conditions; Operating Limits - Electra LEX 25 DCI Service Manual

Lex dci series
Hide thumbs Also See for LEX 25 DCI:
Table of Contents

Advertisement

3.

RATING CONDITIONS

Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units).
Cooling:
Indoor:
27
Outdoor: 35
Heating:
Indoor:
20
Outdoor: 7
3.1

Operating Limits

3.1.1
R410A
Cooling
Heating
Voltage
SM LEXDCI 1-E.1 GB
o
o
C DB 19
C WB
o
C DB
o
C DB
o
o
C DB 6
C WB
Upper limit
o
32
C DB 23
Lower limit
21
o
C DB 15
Upper limit
Lower limit
CONTENTS
RATING CONDITIONS
Indoor
o
C WB
o
C WB
o
o
27
C DB
24
C DB 18
o
o
10
C DB
-15
C DB -16
198 – 264 V
Outdoor
o
46
C DB
-10
o
C DB
o
C WB
o
C WB
3-1

Hide quick links: