3.
RATING CONDITIONS
Standard conditions in accordance with ISO 5151, ISO 13253 (for ducted units)
and EN 14511.
Cooling:
Indoor:
Outdoor: 35
Heating:
Indoor:
Outdoor: 7
3.1
Operating Limits
Cooling
Heating
Voltage
Service Manual – WNG DCI
o
o
27
C DB 19
C WB
o
C DB
20
o
C DB
o
o
C DB 6
C WB
Upper limit
Lower limit
Upper limit
Lower limit
1PH
3PH
RATING CONDITIONS
Indoor
o
o
32
C DB 23
C WB
21
o
C DB 15
o
C WB
o
27
C DB
o
10
C DB
198 – 264 V
N/A
Revision 0
CONTENT
Outdoor
o
46
C DB
-10
o
C DB
o
o
24
C DB 18
C WB
o
o
-15
C DB -16
C WB
3-1