XSMALL
4.1.
Water circuit
Compensation valve 16/18 bar
Pump
Turbine
Water tank
Turbine
Pump
Compensation
valve
•
Traditional water system
•
Turbine - Amount of coffee dispensed into the cup
•
Reciprocating piston type pump (13 - 15 bar)
•
Compensation valve (opening pressure 17 - 19 bar)
•
Boiler - 1300 W
•
Presblok valve - select coffee - hot water - steam
Saeco Int.
1300 W boiler
Compensation valve water outlet
Water tank rapid
connection
Boiler
Presblock
valve
Brewing unit
Water collection tank
Rev. 00 / Jul. 2008
04 OPERATING LOGIC
Steam
valve
Steam hose connection
Steam hose
Control
ringnut
Coffee
dispenser
Page 1 / 6