Firmware Update Procedure - Addonics Technologies HDUS11SNDX User Manual

1:11 hdd duplicator
Table of Contents

Advertisement

Firmware Update Procedure

4. Insert this drive to the Source slot of the duplicator. For subsystem, connect the drive to the
Source SATA port
5. Select "Firmware Update" function under the "Setup" or "Advanced Setup" menu and press
ENT to do the update. To access the "Advanced Setup", hold onto the ESC button for 5 seconds.
The new option will appear
Notes:
SECURE ERASE - HDD duplicator sends a WIPE
OVERWRITE - There are three options: One pass, 3 passes and 7 passes 5220.22-M. The duplicator
writes a string of pattern over the entire disk one time, three times or seven times. (5220.22-M is
the DoD standard for drive sanitization)
Please note that some drives may become locked and cannot be initialized after the SECURE ERASE
or OVERWRITE. Should this happen, use the following procedures to unlock the drive:
1. Place drive in the source slot
2. Execute "PreScan" function for 1 minute
3. Press "ESC" key until you see "User Abort" on the LCD screen
4. Now remove the drive from the duplicator and connect it to your system, the HDD should be
recognized and be able to initialize again