Item
8-2.
8) Anti bacteria (ANTI BACTERIA) operation
Operation
An anti bacteria operation regularly performs a Hot water supply operation with the set temperature TSC_H = 75°C (can
Mode and
be set with FC_0A).
Control Method
1) How to operate
• Pressing the [HOT WATER] button and then the remote controller [ANTI BACTERIA] button changes the setting to
TSC_H = 75°C at the set cycle and time (both can be set with the remote controller FC) to start ANTI BACTERIA
operation.
• The first auti bacteria operation starts when press the [ANTI BACTERIA] button and starting time come.
• When the set temperature 75°C is reached after the ANTI BACTERIA operation started, the set temperature remains
another 30 minutes (can be set with FC_0B).
• The priority zone determined by the outside temperature selects an operation, Hot water heat pump or hot water
supply heater.
• The hot water heat pump operation, when selected, ignores the hot water supply start condition (TTW < 38°C) and
forcibly performs a hot water operation.
• During ANTI BACTERIA operation (Forcible hot water operation at 75°C), the hot water set temperature display is
not changed. If it is changed from the remote controller, the normal hot water set temperature will be changed.
75 °C hot water supply operation for 30 minutes
• During a 75°C hot water supply operation with ANTI
BACTERIA, the remote controller does not display 75°C.
• Be careful not to burn yourself; Output water may be hotter
than that displayed on the remote controller.
Related FC
FC No.
0A
0B
Remote control
OC
Remote control
OD
Operation flow and applicable data, etc.
HOT WATER button set to "ON"
ANTI BACTERIA button set to "ON"
Anti bacteria start time
75 °C hot water supply operation
Usual hot water supply operation
(Set temperature: 40 °C to 75 °C )
Caution
Setting item
Anti bacteria set temperature
Anti bacteria holding time
Anti bacteria start time
Anti bacteria operation cycle
Default
75°C
30 mins
22:00
7 days
44
Setting available range
70-80°C
0 - 60 mins
0:00-22:00
Every day to 10 days