Delta 21UT024C24 Instruction Manual page 8

Vogue ultra universal 21ut series
Table of Contents

Advertisement

Floor Ceiling Air-Conditioning Unit
Decide the installation location with the customer as follows:
3.2.1 Indoor Unit
(1) Install the unit at a place where is strong enough to withstand the weight of the unit.
(2) The air inlet and outlet of the unit should never be clogged so that the airflow can reach
every corner of the room.
(3) Leave service space around the unit as required in Fig.2.
Floor type
>600
Ceiling type
>600
(4) Install the unit where the drain pipe can be easily installed.
(5) The space from the unit to the ceiling should be kept as much as possible so as for more
convenient service.
3.2.2 Outdoor Unit
Install the unit where it will not be tilted by more than 5°.
① .
During installation, if the outdoor unit has to be exposed to strong wind, it must be fixed
② .
securely.
(1) Outdoor Unit must be fixed on stable and solid surface of floor.
(2) Don't install Outdoor Unit under window or between buildings, and prevent the operation
noise from room.
(3) There should be no obstructions at both air inlet and outlet of indoor and outdoor units for
maintaining well air ventilation.
>600
>300
>600
Fig.2
WARNING!
4
>1000
>1500
>300