Delta 21CK018C24 Instruction Manual

21ck series vogue ultra cassette

Advertisement

INSTRUCTION MANUAL
Vogue Ultra Cassette
21CK Series
WARNING!
Read and follow all safety precautions in
Instruction Manual - improper use can cause
serious injury.
www.delta-dct.com

Advertisement

Table of Contents
loading

Summary of Contents for Delta 21CK018C24

  • Page 1 Vogue Ultra Cassette 21CK Series INSTRUCTION MANUAL WARNING! Read and follow all safety precautions in Instruction Manual - improper use can cause serious injury. www.delta-dct.com...
  • Page 2: Table Of Contents

    CONTENTS Names and functions of parts ..........................2 Safety cautions................................3 Wired remote controller............................5 Displaying Part ............................5 Buttons..............................7 Installation of Wired Controller ......................8 Instruction to Operation ..........................9 Error Display ............................21 Setting of Indoor Room Sensor Installing Wired Remote Controller ...........22 Defrosting control(Heat pump) ........................23 Main board Code Setting ............................25 Names and functions of remote control buttons ....................26 Errors display and buttons of LED board ......................29...
  • Page 3: Names And Functions Of Parts

    1 Names and functions of parts...
  • Page 4: Safety Cautions

    2 Safety cautions ●Read the following carefully to assure safe use. NOTE: Children should be supervised to ensure that they do not play with the appliance.
  • Page 5 NOTE: This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 6: Wired Remote Controller

    3 Wired remote controller 3.1 Displaying Part Fig.3.1.1 Outline of wired controller 3.1.1 LCD Display of Wired Controller Fig.3.1.2 LCD display...
  • Page 7 3.1.2 Instruction to LCD Display Description Instruction to Displaying Contents Swing Swing function Air * Air exchange function Sleep Sleeping states Running mode Each kind of running mode of indoor unit (auto mode) Cooling Cooling mode Dry mode Fan mode Heating Heating mode Defrost *...
  • Page 8: Buttons

    3.2 Buttons 3.2.1 Silk Screen of Buttons Fig. 3.2.1 Silk screen of buttons 3.2.2 Instruction to Function of Buttons Description Function of Button (1) Function selection and canceling; Enter/cancel (2) Press it for 5s to enquiry the outdoor ambient temperature. * ▲...
  • Page 9: Installation Of Wired Controller

    3.3 Installation of Wired Controller Fig.3.3.1: Sketch for Installation of Wired Controller Description Socket’s base box Soleplate of Screw M4X25 Front panel of Screw ST2.2X6.5 installed in the controller controller wall Fig.3.3.1: Sketch for Installation of Wired Controller. Pay attention to the following items during installation of wired controller: 1.
  • Page 10: Instruction To Operation

    3.4 Instruction to Operation 3.4.1 On/Off Press On/Off button to turn on the unit. Repress this button to turn off the unit. Note: The state shown in Fig.3.4.1 indicates off-state of the unit after energization. The state shown in Fig.3.4.2 indicates on-state of the unit after energization. Fig.3.4.1 Off state of the unit Fig.3.4.2 On state of the unit 3.4.2...
  • Page 11 3.4.3 Temperature Setting Press ▲ or ▼ button to increase or decrease of setting temperature under on-state of the unit. If press either of them continuously, temperature will be increased or decreased by 1°C every 0.5s. In Cooling, Dry, Fan and Heating mode, temperature setting range is 16°C~30°C. In Auto mode, the setting temperature is un-adjustable.
  • Page 12 3.4.5 Swing Control Function Under on-state of unit, press Function button till the unit enters swing control function and then press “Enter/cancel “ button to turn on “swing” control function. During swing function, press Function button till the unit enters swing control function and then press Enter/cancel button to cancel swing control function.
  • Page 13 will be switched to timer on setting mode. In this case, LCD displays xx. Hour, with ON blinking. In this case, press▲ or ▼ button to adjust timer on and then press Timer button to confirm. When LCD displays xx. Hour On Off, xx. Hour means time of timer off, but time of timer on won’t be displayed.
  • Page 14 3.4.7 Air Exchange Setting* Turn on air Exchange function: Under on-state of the unit, press Function button to go to the this function setting (Air mark blinks).AIR 1 displayed at the ambient temperature-displayed location (888) is defaulted (the last type of AIR will be displayed after adjustment).Press ▲...
  • Page 15 3.4.8 Sleep Setting Sleep on: Press Function button under on-state of the unit into sleep function and then press Enter/cancel button to turn on sleeping function. Sleep off: During sleep on-state, press Function button to go to the sleep function and then press Enter/cancel button to turn off this function.
  • Page 16 3.4.9 Turbo Function Setting TURBO function: The unit at high fun speed can realize quick cooling or heating so that room temperature can quickly approach setting temperature. In cooling or heating mode, press Function button till the unit enters TURBO function and then press Enter/cancel button to turn on TURBO function.
  • Page 17 3.4.10 SAVE Function Setting Energy Saving Function: Energy saving can make the air conditioner runs in a smaller temperature range by setting lower limited value of setting temperature in cooling or dry mode and upper limited value in heating mode. Energy Saving Setting for Cooling Under on-state and in cooling or dry mode of the unit, press Function button into energy saving function , with SAVE blinking .Press ▲...
  • Page 18 3.4.11 E-HEATER Setting* E-HEATER: In the heating mode, E-heater is allowed to be turned on for improvement of efficiency. If heating mode is turned on by button operation, auxiliary electric heating function will be automatically turned on. Press Function button in heating mode to go to the auxiliary electric heating function, the E-HEATER blinking, and press Enter/cancel button to turn on this function.
  • Page 19 3.4.12 Blow Function Setting BLOW function: After the unit is turned off, water in evaporator of indoor unit will be automatically evaporated to avoid mildew. In cooling and dry mode, press Function button till the unit enters BLOW function, with BLOW blinking, and then press Enter/cancel button to turn on this function.
  • Page 20 3.4.13 Quiet Function Setting Quiet function consists of two kinds: QUIET and AUTO QUIET. Press Function button till the unit enters quiet function setting state, Quiet or Auto Quiet mark blinks. In this case, press▲ or ▼ button to switch between Quiet and Auto Quiet and then press Enter/cancel button to turn on this function.
  • Page 21 3.4.14 Field Functions Under off-state of the unit, press Function and Timer buttons continuously for 5s to go to the debugging menu. Press Mode button to adjust the setting items and ▲ or ▼ button to set the actual value. 3.4.14.1 Ambient Temperature Sensor Setting In field setting mode, press Mode button to adjust the temperature displayed location displaying 00, and press ▲...
  • Page 22: Error Display

    3.5 Error Display If there is malfunction during running of the system, LCD will display error code at temperature–displayed location. Once there is more than one malfunction, error codes will be displayed circularly. If there are multiple circuit systems, the system number of failed system will be displayed before the colon (not for single system). If malfunction occurs, turn off the unit and contact nearest dealer for help.
  • Page 23: Setting Of Indoor Room Sensor Installing Wired Remote Controller

    3.6 Setting of Indoor Room Sensor Installing Wired Remote Controller 3.6.1 Setting of Double Indoor Room Sensors This series of ducted air-conditioning unit has two indoor room sensors. One is located at the air intake of the indoor unit and the other one is located inside the wired controller. User can select one from the two indoor room sensors on the basis of the engineering requirement.
  • Page 24: Defrosting Control(Heat Pump

    Fig.3.6.2 Fig.3.6.3 Caution: During the installation of the bottom plate of the wired controller, pay attention to the direction of the bottom plate. The plate’s side with two notches must be at the lower position, otherwise the panel of the wired controller cannot be correctly installed.
  • Page 25 Outdoor ambient temp sensor Outdoor ambient temp sensor Outdoor ambient temp sensor works does not work ≥ -3 ≥ -3 ≥ -3 <-3 <-3 <-3 In summary: If the compressor operates for t mins continuously under “heating” mode, the defrosting will start when the defrosting thermistor is under or below T1 temperature for 1 min continuously.
  • Page 26: Main Board Code Setting

    Note: Mainboard LED display instruction LED1 LED2 Normal Operation Flashing every 0.5s Flashing every 0.5s Defrosting High pressure protection Flashing every 0.5s Low pressure protection Flashing every 0.5s Outdoor ambient Temp. sensor Malfunction Defrosting Temp. sensor Malfunction 5 Main board Code Setting Please find the corresponding main board according to the unit type and then check whether the mainboard code is right according to the main board.
  • Page 27: Names And Functions Of Remote Control Buttons

    6 Names and functions of remote control buttons Notes: This remote control is universal .It could be used for many units. Some buttons which are not available in this unit such as “TURBO” 、 “BLOW ”、 “LIGHT”、 “TEMP” 、 “HEALTH|SAVE” will not be described below.
  • Page 28 once , the timing hours will increase or decrease 0.5 hour. ” button 4、“FAN ” button to set fan speed. The AUTO FAN 、LOW、MID、HIGH could be Press the “FAN selected. 5、 button Press this button to turn on or turn off the swing function. 6、...
  • Page 29 Changing batteries and notices 1、 Slightly to press the place with along the arrowhead direction to push the back cover of remote controller.(As show in Fig 1.) 2、 Take out the old batteries ,insert two AAA alkaline cells(As show in Fig 2.) 3、Attach the back cover of remote control.
  • Page 30: Errors Display And Buttons Of Led Board

    7 Errors display and buttons of LED board . There are one yellow LED used as Timer LED, one green LED used as Compressor LED, one red LED used as Run LED on the LED board. AND also two buttons, one is Auto button, the other is Test button .We will introduce the error displaying of the LED and the functions of the buttons 7.1 Errors display ●...
  • Page 31: Optimum Operation

    8 Optimum operation...
  • Page 32: Trouble Shooting

    9 Trouble shooting ★ Warning ● In case of something abnormal (such as bad smell), shut of the power switch immediately and contact service center. ● Do not repair the air conditioner by yourself because wrong repair may cause fire, please contact service center to do it for you ★Check item shown below before contacting service center.
  • Page 33 ★ The following are not troubles...
  • Page 34: Installation Notes

    10 Installation notes...
  • Page 35: Care And Maintenance

    11 Care and maintenance Please pull out the power plug after you used the air conditioner.
  • Page 38 The operation in detach and fix the flap is not including the 18K type.
  • Page 39: Instructions Of Unit Installation

    A、Schematic diagram of installation spaces ≥1500 ≥1500 Unit:mm Fig.1 Models H(mm) 21CK018C24 21CK024C24 21CK036C24 21CK048C24 21CK060C24 B、Select install location of the indoor unit 1. Obstruct should put away from the intake or outlet vent of the indoor unit so that the airflow can be blown though all the room.
  • Page 40 DELTA would not deal with on time by the inconvenience of the business contact. D、Dimension of ceiling opening and location of the hoisting screw (M10)
  • Page 41 21CK024C24、21CK036C24 21CK048C24、21CK060C24 ☆ The drilling of holes in the ceiling must be done by the professional personnel. Installation stands for main body of the unit Ceiling Above 20 Fig 1 Notes: The dimension for the ceiling openings with * marks can be as large as 910mm. But the overlapping sections of the ceiling and the decorated surface boards should be maintained at no less than 20mm.
  • Page 42 Nut (supplied at scene) Gasket (attachment) Insert Hoisting stand Gasket anchor board Tighten (double nuts) (attachment) [ Fix the hoisting stand firmly ] [ Fix the gasket firmly ] Bolt of one of the angle of outlet pipe is fix on the angle of the drainage slot Center of the ceiling opening...
  • Page 43 (inch) Pipe Difference between Refrigerant to be Filled Length Indoor Unit and (For Extra Length of Liquid Outdoor Unit(m) Pipe) Model Pipe Pipe 21CK018C24 60g/m 31VP018 21CK024C24 31VP024 60g/m 21CK036C24 31VP036 21CK042C24 120g/m 31VP048 21CK048C24 31VP060 Note: 1、The standard pipe length is 5m,When the length(L) of the connecting pipe is less than or equals 5m,there is no need to add refrigerant.
  • Page 44 ☆ If drain hose cannot has enough drooping gradient, drain raising pipe should be added. ☆ To prevent bent of the drain hose, the distance between hoisting stand should is 1 to 1.5m. 1-1.5m ○ × (Correct) 1/100 or more gradient (wrong) ☆...
  • Page 45: Electric Wiring

    T-tie in join drain hose Above100mm The specs of the selected join drain hose should fits the running capacity of the unit. ☆ Check the smoothness of drain after installation. ☆ Check the drain state by immitting 600cc water slowly from the outlet vent or test hole. ☆...
  • Page 46: Installation Of Panel

    ● Wiring of unit and the controller 1. Wiring of the indoor unit. Remove the control box lid, pull the wires inside through rubber bush and wiring according to the WIRING DIAGRAM , then tighten it with clamp. 2. Wiring of the controller 1) Remove the control box lid, pull wires inside through rubber bush and connect to the controller.
  • Page 47 3、Screw all 4 hexagon head screws located right beneath the latches in approximately 15mm.(panel will rise) 4、Adjust the panel by turning it to the arrowed direction in Fig.4 so that the ceiling opening is completely covered. 5、Tighten the screws until the thickness of the sealing material between the panel and the indoor unit body is reduced to 5~8 mm.
  • Page 48 2. If gap is still left between the ceiling and the panel after screwing the screws, readjust the height of the indoor unit body (Refer to Fig.6) Fig.6 ● After fixing be sure no gap left between the ceiling and the panel 3、Wiring of the decoration panel.
  • Page 49 butted terminals Fig.8 Fig.9...
  • Page 50: Install Of Outdoor Unit

    12.4 Install of outdoor unit A、Profile Dimensions of Outdoor Unit B、Schematic diagram of installation spaces C、Precautions on Installation of Outdoor Unit To ensure the unit in proper function, selection of installation location must be in accordance with following principles: (1) Outdoor unit shall be installed so that the air discharged by outdoor unit will not return and that sufficient space for repair shall be provided around the machine.
  • Page 51 enough air. Ensure that there is no obstacle for the air intake and exhaust of the outdoor unit. If there is any obstacle blocking the air intake or exhaust, remove it. (3) Place of installation shall be strong enough to support the weight of outdoor unit, and it shall be able to insulate noise and prevent vibration.
  • Page 52 Fig 11 (4) Confirm the specification of cooling/heating throttle orifice according to model of the unit (marked on the unit). Model of Unit Cooling throttle orifice Heating throttle orifice 21CK018C24 047# 040# 21CK024C24 056# 045# 21CK036C24 065#...
  • Page 53 Install the throttle valve and throttle orifice according to the above sequence. Meanwhile, the seal rings shall be installed properly at joints to prevent leakage. Model Torque moment 2 0±5(N·m) 21CK018C24 2 0±5(N·m) 21CK024C24 2 0±5(N·m) 21CK036C24 2 0±5(N·m) 21CK048C24 2 0±5(N·m)
  • Page 54 The following table describes the torques for tightening nuts of different pipe diameters. Pipe Diameter Tightening Torque φ6.34mm 15-30 (N·m) φ9.52mm 35-40 (N·m) φ15.88mm 60-65 (N·m) φ12.7mm 45-50 (N·m) φ19.05mm 70-75 (N·m) φ22.05mm 80-85 (N·m) (3) The bending angle of the fitting pipe shall not be too small, and otherwise the pipe may break. Please use a bender when bending the fitting pipes.
  • Page 55 F、Installation of Protective Layer of Connecting Pipe 1. To avoid generation of condensate on the connecting pipe and avoid leakage, the big pipe and the small pipe of the connecting pipe must be covered by thermal insulation materials, be bundled by adhesive tape, and be isolated from air.
  • Page 56 If concealed installation is adopted, 1# PVC pipe can be used (Refer to Figure 20). 3、No matter if surface mounting or concealed mounting is selected, it is required to drill 2 holes (in the same level) which distance shall be the same as the distance (60mm) of installation holes in the bottom plate of the wire controller.
  • Page 57 I. Power Cable Connection Caution: Before installing the electrical equipment, please pay attention to the following matters which have been specially pointed out by our designers: (1) Check that if the power supply used conforms to the rated power supply specified on the nameplate.
  • Page 58: Products Electric Installation

    5、All line connections must conform to the schematic diagram of lines. Wrong connection may cause abnormal operation or damage of the air-conditioning unit. 6、Do not let any cable contact the refrigerant pipe, the compressor and moving parts such as fan. 7、Do not change the internal line connections inside the air-conditioning unit.
  • Page 59 The model selection recommend table for air switch and power cable Model Power Capacity Outdoor Indoor supply of air power power switch(A) supply supply cord cord 3×2.5 3×4.0 21CK018C24 220V~ H07RN-F H07RN-F 3×2.5 3×4.0 21CK024C24 220V~ H07RN-F H07RN-F 3×6.0 3×1.0 21CK036C24 220V~ H07RN-F H07RN-F 3×10.0 3×1.0...
  • Page 60 ● Requirement for ground ☆ Air conditioner is the I class electric appliance, thus please do conduct reliable grounding measure. ☆ The yellow-green two-color wiring of air conditioner is grounding wire and can not be used for other purposes. It cannot be cut off and be fixed by screw, otherwise it would cause electric shock. ☆...
  • Page 61: Test Operation

    13 Test operation 1. Prepare for test (1) Do not turn on the power switch before all installation is finished. (2) Connect wires correctly and firmly. (3) Open the check valve. (4) Remove all dust. 2. Testing (1) Turn on the power switch and press ON/OFF button. (2) Press MODE button select COOL, HEAT, FAN, etc to test whether it operates normally.
  • Page 62 Items to check If not properly done, what is likely to happen Is the indoor unit fixed firmly? The unit may drop, vibrate or make noise. Is the gas leakage test finished? It may result in insufficient cooling. Is the unit fully insulated? Condensate water may drip.
  • Page 64 Thank you for Choosing airconditioners Perfectly engineered for your comfort. www.delta-dct.com...