ZCV39 Clearance to Combustibles

Clearance to Combustibles

Front
Back (from Stand-offs)
Side (from Stand-offs)
Floor*
Minimum Ceiling Height (from bottom of fireplace)
Top (from Stand-offs)
Top of 90° Bend in minimum Enclosure of 55-1/2"
Top of 90° Bend in Enclosure over 55-1/2"
VENTING SYSTEMS
Top of Horizontal Pipe
Side & Bottom of Horizontal Pipe
Vertical Vent Pipe
*Note: If appliance is installed directly on
carpeting or other combustible material
other than wood flooring, a metal or wood
panel extending the full width and depth of
the appliance must be used. Carpet may
extend 1 inch above the floor of the
appliance.
ZCV39
36" [92cm]
0" [0cm]
0" [0cm]
0" [0cm]
55-1/2" [141cm]
0" [0cm]
4" [10.2cm]
4" [10.2cm]
1/1/2" [3.8cm]
1" [2.5cm] All Vent Systems
1" [2.5cm] All Vent Systems
48" MIN for NG
60" MIN for LP
Plus Rise of 1/4"
Per Foot*