1
2+
2+
balanced XLR
1
MALE connector
3-
3-
balanced XLR
FEMALE socket
PROFESSIONAL LOUDSPEAKER SYSTEM
PROFESSIONAL LOUDSPEAKER SYSTEM
3.3 - SYSTEM WIRING
AC mains connection
- Make sure that the ac line voltage value corresponds to the one indicated
on rear panel.
- Connect the mains supply cable to a socket fitted with a proven ground
contact.
3.3.1 - Wiring of signal cables
The input socket IN (4) and the LINK socket (5) are XLR 3 pole connectors,
female (IN) and male (LINK).
They are wired according to IEC 268 (AES1492) standards:
pin 1 = ground, pin 2 = hot (+), pin 3 = cold (-).
The SUB OUT socket is an XLR 3 pole connector male.
Use only screened cables (signal cables) of suitable size and quality.
Connector wiring is illustrated in the following images.
2
1
3
balanced XLR
MALE socket
balanced XLR
FEMALE connector
user's manual
1 GND
Ground
2 +
Hot
3 -
Cold
(IEC 268 standard)
15
ENGLISH