HD-101r

waTer pUmp SeTUp For operaTion

The Water Pump can be setup for operation in two ways, External Water Source or Re-circulation.
noTe:
If using a dry blade for operation, DO NOT connect the water pump.
eXTernal waTer SoUrCe
This is the preferred method of cooling.
(A)
Remove the Drain Plug. Place
empty container under hole for
water drainage
re-CirCUlaTion
noTe:
When using the re-circulation method, the water should be changed often for longer pump life.
(A)
Ensure the Drain Plug is in-
stalled in the Water Basin
CaUTion
1. Before powering or starting, check for damage that could prevent this equipment
2. Verify the On/Off switch is in the OFF position.
3. Before connecting the HD-101R to a power supply, be sure the voltage, cycle
and phase of the job site power source meet the requirements.
Place the Water Pump in an
external container and fill until
water completely covers the Water
Place the Water Pump in the
back of the Water Basin
from proper operation or performing it's intended function. Check for binding and
alignment of moving parts. Check for damaged, broken, or missing parts.
(B)
Pump suction
(B)
27