B. WHEN VENT PIPE EXTENDS TO CHIMNEY TOP (Refer to Figure 15)
1.
You will need a pipe length equal to the chimney height (from hearth) plus 6 inches. If outside combustion air is to be used, you
will need a pipe length (see "COMBUSTION AIR SUPPLY") equal to the chimney height plus 12 inches.
2.
Attach cerablanket wrap to the end of vent pipe that will connect to the stove. Use 12-inch lengths of light gauge metal wire (not
included) or metallic tape (not included). Th is is to protect interior components from excess heat.
3.
Set the insert on the hearth and slide it in far enough to attach the vent pipe (and combustion pipe if used).
4.
Attach fl ashing (refer to Figure 14), route power cord out the side nearest a 120V receptacle. Slide in insert.
5.
Measure and build chimney top. Cut out hole for vent pipe (and combustion air intake pipe, if used). Install and seal with a non-
hardening mastic to prevent water leakage. Install the vent cap.
C. WHEN VENT PIPE EXTENDS THROUGH CHIMNEY BLANKING PLATE (Masonry Fireplaces Only) (Refer to Figure 15)
1.
You will need a pipe length that extends 12" above the blanking plate. NOTE: Th is installation is optional but not recommended.
Outside combustion air cannot be drawn from the chimney cavity in this installation.
2.
Attach cerablanket wrap to that end of vent pipe that will connect to the stove. Use 12-inch lengths of light gauge metal wire (not
included) or metallic tape. Th is is to protect interior components from excess heat.
3.
Measure and build blanking plate. Cut out hole for vent pipe (and combustion air intake pipe, if used). Install and carefully seal
blanking plate with non-hardening mastic. Failure to properly seal may result in smoke spillage.
4.
Slide vent pipe (and intake pipe if used) up through the blanking plate hole, leaving enough to pull back down.
5.
Set the insert on the hearth, adjust the leveling bolts on the rear sides, and slide it in far enough to attach the vent pipe (and com-
bustion air pipe if used). Be sure to seal where the pipe passes through the blanking plate.
6.
Attach fl ashing (refer to Figure 14), route power cord out the side nearest a 120V receptacle. Slide in insert.
12
INSTALLATION
INSTALLATION
FIGURE 15