Kränzle Technology; Water And Cleaning System - Kranzle Therm 870-1 Operating Manual

Hot water high-pressure cleaners
Table of Contents

Advertisement

Please note - important!
10
Insufficient quantity of electricity
Check the line fusing and have the voltage and the available current
intensity checked by an expert in case of uncertainty.
Electrical connection
The machine is supplied with an electrical power cable with plug. The mains plug must
be fitted to a standard grounded socket with a 30 mA residual current operated device.
The socket must be protected with a 16A delay action fuse on the mains side
using an extension cable, this must have an earthed lead which is properly connected to
the socket. The conductors in the extension cable must have a minimum cross section of
1.5 mm². Plug connections must be of a spray-proof design, and may not be located on
a wet floor. With extension cables of more than 10 m the minimum cross section must
be 2.5 mm! When using a cable drum, always keep the cable wound as far as possible
Kränzle technology

Water and Cleaning System

The water is fed to the high-pressure cleaner under pressure (2-8 bar pre-pressure). A
float valve regulates the water flow in the storage tank. Then the water is sucked directly
from the storage tank by the high-pressure pump and forced with the adusted pressure
through the heat exchanger to the safety spray lance. The high pressure jet is formed by
the nozzle at the end of the safety lance.
Environmental, refuse disposal and water protection regulations
must be observed!
If there are too many collectors in your
proximity connected to the network at the
same time, the available voltage and the
current intensity may decline.
Consequently the motor of the high-pres-
sure cleaner does not start or even blows.
The power supply may also be insufficient
if the power cable is too long or too thin. If
extension cables are too long, this may
lead to a voltage drop causing
malfunctions or start-up difficulties
.
When
.