2.5.14 Technical data

GENERAL
Model
RPM
Alternator
Engine
Number of cylinders
Displacement
Bore X stroke
Combustion air consumption
Continuous power engine
Cooling system
Fuel lift pump engine
Starting battery (optional)
Fuel consumption
Control
ELECTRICAL SPECIFICATIONS
Output voltage
Output rating
Voltage tolerance
Frequency tolerance
Alternator
Voltage regulation:
MECHANICAL SPECIFICATIONS
Supply includes
Dimensions hxwxd
Colour
Weight
Max. installation angle
Standard supplies
Available as option:
EN / WHISPER 16 Ultra - Three phase for mobile applications / October 2008 / Copyright © 2008 Mastervolt
WHISPER 16 ULTRA, Three phase, mobile applications
1500
3 phase synchronous (air cooled)
Mitsubishi diesel, model S4Q2 (Japan)
4
2505 cm3
80x103 mm
2.5 m³/min.
16 kW electric power
By means of a radiator.
Mechanical driven, manual priming,
additional electric pump (12 V DC) available upon request
110 Ah 12V
2-7 litre/hour, load dependent
Digital Diesel Control including automatic start/stop
230/400V 50 Hz alternating current (AC) three phase,
re-connectable to three phase 230V
16 kVA = 16kW at power factor cos phi = 1
± 2% (balanced load)
± 3%
Air cooled, brushless, four pole, 6 or 12 wire, synchronous
AVR
Sound shield with steel base, mounted on rubber anti vibration mounts. (Generator
set without sound shield is optional)
116.0 x 68.0 x 70.0 cm
Metallic silver / grey
454 kg including sound shield
25 degrees
Digital remote panel (+15 m cable), fuel filter, fuel lift pump, user and installation
manuals
Installation kits, non earth return (ungrounded), spare part kits